Skip to content
SafetyRecord logoSafetyRecord
FENBAR PRECISION MACHINISTS INC.
$3,050
penalties
18
viol.
4
insp.

FENBAR PRECISION MACHINISTS INC.

633 COMMERCE STREET, Thornwood, NY 10594NAICS 332116

Inspections
4
Sep 2002 to May 2007 · 3 safety, 1 health
Violations
18
across 4 inspections
Penalties on record
$3,050
latest amounts in DOL records
By classification
Serious 14Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 25, 2007Complaint (B) · Complete scope, Safety#309599801$00 viol.

Inspection #309599801

Dates

Opened
May 25, 2007
Closing Conference Date
May 25, 2007
Closed
May 25, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
633 Commerce Street, Thornwood, NY 10594
Industry
332116

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jul 15, 2003Monitoring (D) · Partial scope, Safety#305771743$00 viol.

Inspection #305771743

Dates

Opened
Jul 15, 2003
Closing Conference Date
Jul 15, 2003
Closed
Oct 2, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
633 Commerce Street, Thornwood, NY 10594
Industry
332116

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 10, 2002Planned (H) · Complete scope, Safety#305767014$2,60011 viol.

Inspection #305767014

Dates

Opened
Oct 10, 2002
Closing Conference Date
Oct 10, 2002
Closed
Dec 29, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 other-than-serious
Initial Penalties
$4,350
Penalties on Record
$2,600
Site Address
633 Commerce Street, Thornwood, NY 10594
Industry
332116

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious11$750$450May 15, 2003--
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious11$0$0Apr 15, 2003--
01001C1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious13$0$0Apr 15, 2003--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious43$600$350Mar 26, 2003--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious12$750$450Mar 26, 2003--
01004A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious31$1,500$900Oct 10, 2003--
01004B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious12$0$0Oct 10, 2003--
01004C1910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious12$0$0Mar 26, 2003--
01005A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious42$750$450Mar 26, 2003--
01005B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious32$0$0Mar 26, 2003--
020011910.37
OSHA citation code: 19100037 Q06
Other15$0$0Mar 26, 2003--
Sep 25, 2002Complaint (B) · Partial scope, Health#304376130$4507 viol.

Inspection #304376130

Dates

Opened
Sep 25, 2002
Closing Conference Date
Oct 10, 2002
Closed
Dec 16, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
4 serious, 3 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$450
Site Address
633 Commerce Street, Thornwood, NY 10594
Industry
332116

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC42P / 2A0.0986 - 0.2008mg/m³
Oil Mist, Mineral42P / 2A0.0986 - 0.2008mg/m³
Sample WeightQC42P / 2A0.03 - 0.079mg

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
OSHA citation code: 19100037 Q02
Serious18$450$225Nov 8, 2002--
01002A1910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious15$600$0Dec 10, 2002--
01002B1910.133
Eye and Face Protection
OSHA citation code: 19100133 A03
Serious14$0$0Dec 10, 2002--
010031910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious11$450$225Nov 20, 2002--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 K06
Other14$0$0Nov 8, 2002--
02002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other18$0$0Nov 8, 2002--
02002B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other28$0$0Nov 8, 2002--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses4 citations · $1,350
1910.147The control of hazardous energy (lockout/tagout)3 citations · $450
1910.1200Hazard Communication2 citations · $0

Chemical exposure sampling

Samples
12
Substances
3
Inspections
1

Industry comparison

Violations per inspection
This employer4.5
Industry average3.3
Penalties per inspection
This employer$763
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,919 employers with OSHA inspections. Arithmetic from DOL records.