FORT KNOX SECURITY PRODUCTS
1051 NORTH INDUSTRIAL PARK ROAD, OREM, UT 84057
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 14, 1999#126797711Jan 14, 1999Complaint (B) · Complete scope, Health#126797711$1,20021 viol.21 violations$1,200 in penalties
Inspection #126797711
Dates
- Opened
- Jan 14, 1999
- Closing Conference Date
- Jan 22, 1999
- Closed
- Mar 6, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 75
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 21
- Violation Types
- 4 serious, 17 other-than-serious
- Initial Penalties
- $1,200
- Penalties on Record
- $1,200
- Site Address
- 993 N Industrial Dr, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 10 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 10 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 10 | 0 - 0.0046 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 10 | 0 | mg/m³ |
| Copper Fume (as Cu) | 10 | 0.0106 - 0.1262 | mg/m³ |
| Iron Oxide Fume | 10 | 1.0617 - 13.8273 | mg/m³ |
| Lead, Inorganic (as Pb) | 10 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 10 | 0.061 - 0.7433 | mg/m³ |
| Methylene Chloride | 3 | 11.8595 - 35.1889 | ppm |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 10 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 10 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 10 | 0 | mg/m³ |
| Zinc Oxide Fume | 10 | 0 | mg/m³ |
Violations
Violation list (6 of 21 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 10005 OSHA citation code: 10005 D03 | Serious | 1 | 12 | $600 | $600 | Jul 21, 1999 | - | - |
| 01001B | 1910.252 General requirements OSHA citation code: 19100252 C01 III | Serious | 1 | 12 | $0 | $0 | Jul 21, 1999 | - | - |
| 01001C | 1910.252 General requirements OSHA citation code: 19100252 C02 I | Serious | 1 | 12 | $0 | $0 | Jul 21, 1999 | - | - |
| 01002 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 D01 | Serious | 1 | 2 | $600 | $600 | Mar 29, 1999 | - | - |
| 01007 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 III | Other | 1 | 16 | $0 | $0 | Apr 26, 1999 | - | - |
| 02001 | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Other | 1 | 40 | $0 | $0 | Apr 26, 1999 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 21 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jul 12, 1995#126747484Jul 12, 1995Planned (H) · Complete scope, Health#126747484$04 viol.4 violations$0 in penalties
Inspection #126747484
Dates
- Opened
- Jul 12, 1995
- Closing Conference Date
- Jul 12, 1995
- Closed
- Oct 5, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 65
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1051 North Industrial Park Road, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Other | 1 | 20 | $0 | $0 | Oct 4, 1995 | - | - |
| 01002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B10 | Other | 1 | 20 | $0 | $0 | Oct 4, 1995 | - | - |
| 01003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 | Other | 1 | 20 | $0 | $0 | Oct 4, 1995 | - | - |
| 01004 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G02 II | Other | 1 | 20 | $0 | $0 | Oct 4, 1995 | - | - |
May 1, 1990#105613178May 1, 1990Follow-Up (F) · Partial scope, Health#105613178$00 viol.0 violations$0 in penalties
Inspection #105613178
Dates
- Opened
- May 1, 1990
- Closing Conference Date
- May 1, 1990
- Closed
- Jul 16, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 26
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1051 North Industrial Park Road, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Nov 13, 1989#105599666Nov 13, 1989Planned (H) · Complete scope, Health#105599666$44016 viol.16 violations$440 in penalties
Inspection #105599666
Dates
- Opened
- Nov 13, 1989
- Closing Conference Date
- Nov 17, 1989
- Closed
- Oct 21, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 16
- Violation Types
- 2 serious, 14 other-than-serious
- Initial Penalties
- $440
- Penalties on Record
- $440
- Site Address
- 1051 North Industrial Park Road, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 21 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 21 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 21 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 21 | 0 - 0.0054 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 21 | 0 - 0.0263 | mg/m³ |
| Copper Fume (as Cu) | 21 | 0 - 0.0347 | mg/m³ |
| Iron Oxide Fume | 21 | 0 - 7.8386 | mg/m³ |
| Lead, Inorganic (as Pb) | 21 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 21 | 0 - 0.4786 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 21 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 21 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 21 | 0 | mg/m³ |
| Zinc Oxide Fume | 21 | 0 - 0.2344 | mg/m³ |
Violations
Violation list (6 of 16 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | GEN0217020300001 | Serious | 1 | 4 | $0 | $0 | Apr 15, 1990 | - | - |
| 01001B | GEN0217020400001 | Serious | 2 | 4 | $440 | $440 | Jan 11, 1990 | - | - |
| 01012 | GEN01780102 | Other | 4 | 10 | $0 | $0 | Jan 22, 1990 | - | - |
| 02001 | GEN00040401 | Other | 1 | 40 | $0 | $0 | Jan 11, 1990 | - | - |
| 02002 | GEN00220401 | Other | 2 | 10 | $0 | $0 | Jan 11, 1990 | - | - |
| 02003 | GEN00370606 | Other | 2 | 20 | $0 | $0 | Jan 11, 1990 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 10, 1987#105577845Nov 10, 1987Complaint (B) · Partial scope, Safety#105577845$02 viol.2 violations$0 in penalties
Inspection #105577845
Dates
- Opened
- Nov 10, 1987
- Closing Conference Date
- Nov 10, 1987
- Closed
- Mar 28, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1051 North Industrial Park Road, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | GEN0107020500001 | Other | 1 | 2 | $0 | $0 | Nov 30, 1987 | - | - |
| 01002 | GEN12000501 | Other | 1 | 4 | $0 | $0 | Dec 30, 1987 | - | - |
Oct 29, 1986#102104239Oct 29, 1986Planned (H) · Complete scope, Safety#102104239$05 viol.5 violations$0 in penalties
Inspection #102104239
Dates
- Opened
- Oct 29, 1986
- Closing Conference Date
- Oct 29, 1986
- Closed
- Jan 7, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 17
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1051 North Industrial Park Road, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | GEN01060506 OSHA citation code: GEN01060506 000 | Other | 1 | 1 | $0 | $0 | Nov 18, 1986 | - | - |
| 01002 | GEN02120105 | Other | 2 | 2 | $0 | $0 | Nov 18, 1986 | - | - |
| 01003 | GEN02190503 OSHA citation code: GEN02190503 000 | Other | 3 | 4 | $0 | $0 | Nov 24, 1986 | - | - |
| 01004 | GEN12000501 | Other | 1 | 1 | $0 | $0 | Dec 17, 1986 | - | - |
| 01005 | GEN12000708 | Other | 1 | 1 | $0 | $0 | Dec 17, 1986 | - | - |
Sep 7, 1983#218007797Sep 7, 1983Follow-Up (F) · Partial scope, Safety#218007797$00 viol.0 violations$0 in penalties
Inspection #218007797
Dates
- Opened
- Sep 7, 1983
- Closing Conference Date
- Sep 7, 1983
- Closed
- Mar 22, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 13
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1051 N Industrial Park Drive, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Jun 30, 1983#218007326Jun 30, 1983Planned (H) · Complete scope, Safety#218007326$010 viol.10 violations$0 in penalties
Inspection #218007326
Dates
- Opened
- Jun 30, 1983
- Closing Conference Date
- Jun 30, 1983
- Closed
- Sep 7, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 13
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 10 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1051 N Industrial Park Dr, Orem, UT 84057
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | GEN010105 | Other | 2 | - | $0 | $0 | Jul 25, 1983 | - | - |
| 01002 | GEN0141034 | Other | 2 | - | $0 | $0 | Jul 19, 1983 | - | - |
| 01003 | GEN0178161 | Other | 1 | - | $0 | $0 | Aug 18, 1983 | - | - |
| 01004 | GEN021202 | Other | 1 | - | $0 | $0 | Jul 25, 1983 | - | - |
| 01005 | GEN0215029 | Other | 2 | - | $0 | $0 | Aug 1, 1983 | - | - |
| 01006 | GEN0219053 OSHA citation code: GEN0219053 00001 | Other | 1 | - | $0 | $0 | Aug 18, 1983 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
8 inspections, 1983 to 1999. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.