FREEMAN DESIGN DISPLAY
$980
penalties
24
viol.
4
insp.

FREEMAN DESIGN DISPLAY

4015 W 11TH ST, HOUSTON, TX 77055

Inspections
4
Jun 1985 to Dec 1985 · 3 safety, 1 health
Violations
24
across 4 inspections
Penalties on record
$980
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 3, 1985Follow-Up (F) · Partial scope, Safety#100253251$00 viol.

Inspection #100253251

Dates

Opened
Dec 3, 1985
Closing Conference Date
Dec 3, 1985
Closed
Dec 4, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
29

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4015 W 11th St, Houston, TX 77055
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Nov 14, 1985Follow-Up (F) · Partial scope, Safety#100268887$00 viol.

Inspection #100268887

Dates

Opened
Nov 14, 1985
Closing Conference Date
Nov 14, 1985
Closed
Dec 5, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
29

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4015 W 11th St, Houston, TX 77055
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 17, 1985Referral (C) · Partial scope, Health#2299238$2801 viol.

Inspection #2299238

Dates

Opened
Jul 17, 1985
Closing Conference Date
Sep 3, 1985
Closed
Sep 24, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
29
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$560
Penalties on Record
$280
Site Address
4015 West 11th St, Houston, TX 77055
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling4 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone30 - 1.2ppm
Acetone33.1 - 6.2ppm
Toluene38.2 - 16.4ppm
Xylene30.3 - 2.5ppm

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 H07 IA
Serious12$560$280Sep 9, 1985--
Jun 26, 1985Planned (H) · Complete scope, Safety#2174555$70023 viol.

Inspection #2174555

Dates

Opened
Jun 26, 1985
Closing Conference Date
Jul 2, 1985
Closed
Dec 6, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
29

Violations and Penalties

Total Violations
23
Violation Types
14 serious, 9 other-than-serious
Initial Penalties
$1,400
Penalties on Record
$700
Site Address
4015 W 11th St, Houston, TX 77055
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious13$120$60Aug 12, 1985--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious12$120$60Oct 31, 1985--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious12$80$40Aug 12, 1985--
010041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G01
Serious13$120$60Aug 12, 1985--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$80$40Aug 12, 1985--
010061910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious21$120$60Aug 12, 1985--
010071910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious31$80$40Aug 12, 1985--
010081910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious21$120$60Aug 12, 1985--
010091910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious21$120$60Aug 12, 1985--
010101910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 I01
Serious21$80$40Aug 12, 1985--
01011A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$80$40Aug 12, 1985--
01011B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Aug 12, 1985--

Showing the 12 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties1 citation, $450 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01008#100268887Nov 19, 1985$450--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials9 citations · $220
1910.213Woodworking Machinery Requirements5 citations · $260
1910.219Mechanical Power-Transmission Apparatus2 citations · $40

Chemical exposure sampling

Samples
12
Substances
4
Inspections
1

Other inspected employers in HOUSTON, TX