Skip to content
SafetyRecord logoSafetyRecord
GALVESTON SHIPBUILDING CO
$9,412
penalties
56
viol.
17
insp.

GALVESTON SHIPBUILDING CO

, Galveston, TX 00000

Inspections
17
Aug 1976 to Jul 1997 · 10 safety, 7 health
Violations
56
across 17 inspections
Penalties on record
$9,412
latest amounts in DOL records
By classification
Serious 36Willful 0Repeat 0Other 20

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 30, 1997Complaint (B) · Partial scope, Health#301401238$6,13223 viol.

Inspection #301401238

Dates

Opened
Jul 30, 1997
Closing Conference Date
Nov 26, 1997
Closed
Apr 7, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
85
Related Activity
1 complaint

Violations and Penalties

Total Violations
23
Violation Types
21 serious, 2 other-than-serious
Initial Penalties
$14,700
Penalties on Record
$6,132
Site Address
6800 Port Industrial Blvd., Galveston, TX 77554
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Chromium, Metal and Insoluble Salts20 - 0.0041mg/m³
Cobalt, Metal, Dust and Fume (as Co)20 - 0.0019mg/m³
Copper Fume (as Cu)20 - 0.019mg/m³
Gravimetric DeterminationQC40 - 25mg/m³
Iron Oxide Fume20 - 9.012mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20 - 0.4555mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20 - 0.001mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20 - 0.0047mg/m³
Sample WeightQC40 - 17.218mg
Silica, Crystalline Quartz (Respirable Fraction)31 - 1.3%
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20 - 0.011mg/m³

Violations

Violation list (5 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious33$875$438Mar 30, 1998--
010021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious15$875$438Jan 26, 1998--
010031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious55$875$438Mar 30, 1998--
01004A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 IIA
Serious11$875$438Dec 29, 1997--
01004B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I03
Serious11$0$0Jan 11, 1998--

Showing the 5 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 26, 1990Planned (H) · Complete scope, Safety#107626103$2002 viol.

Inspection #107626103

Dates

Opened
Nov 26, 1990
Closing Conference Date
Nov 29, 1990
Closed
Jan 3, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$200
Penalties on Record
$200
Site Address
6800 Port Industrial Blvd., Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$120$120Jan 7, 1991--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious12$80$80Dec 24, 1990--
Jan 26, 1982Planned (H) · Complete scope, Safety#16272775$5404 viol.

Inspection #16272775

Dates

Opened
Jan 26, 1982
Closing Conference Date
Jan 26, 1982
Closed
Feb 25, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
300

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$1,080
Penalties on Record
$540
Site Address
6800 Port Industrial, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious1-$300$150Feb 25, 1982--
010021916.44
OSHA citation code: 19160044 A02
Serious1-$420$210Feb 6, 1982--
010031916.23
OSHA citation code: 19160023 C01 IV
Serious4-$360$180Feb 18, 1982--
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other2-$0$0Feb 6, 1982--
Dec 11, 1981Planned (H) · Complete scope, Health#16268716$00 viol.

Inspection #16268716

Dates

Opened
Dec 11, 1981
Closing Conference Date
Jan 21, 1982
Closed
Feb 26, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
275

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
6800 Industrial Blvd, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 6, 1981Complaint (B) · No Inspection scope, Health#18777797$00 viol.

Inspection #18777797

Dates

Opened
Aug 6, 1981
Closing Conference Date
Not recorded
Closed
Sep 30, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
, Galveston, TX 00000
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Aug 6, 1981Complaint (B) · Partial scope, Health#16278566$00 viol.

Inspection #16278566

Dates

Opened
Aug 6, 1981
Closing Conference Date
Sep 2, 1981
Closed
Sep 4, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
300
Related Activity
2 complaints

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
6800 Industrial Blvd, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

May 7, 1980Follow-Up (F) · Complete scope, Safety#16285876$00 viol.

Inspection #16285876

Dates

Opened
May 7, 1980
Closing Conference Date
May 7, 1980
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
350

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
6800 Industrial Blvd, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 13, 1980Follow-Up (F) · Partial scope, Health#16277774$00 viol.

Inspection #16277774

Dates

Opened
Feb 13, 1980
Closing Conference Date
Feb 13, 1980
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
275

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
6800 Industrial Blvd, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 15, 1980Planned (H) · Partial scope, Safety#16277717$2402 viol.

Inspection #16277717

Dates

Opened
Jan 15, 1980
Closing Conference Date
Jan 23, 1980
Closed
Jul 18, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
275
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$240
Penalties on Record
$240
Site Address
6800 Industrial Blvd, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 A
Serious2-$240$240Feb 12, 1980--
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B03
Serious1-$0$0Mar 18, 1980--
Jan 9, 1980Planned (H) · Complete scope, Safety#16283301$1,8809 viol.

Inspection #16283301

Dates

Opened
Jan 9, 1980
Closing Conference Date
Jan 11, 1980
Closed
May 16, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
350

Violations and Penalties

Total Violations
9
Violation Types
7 serious, 2 other-than-serious
Initial Penalties
$1,880
Penalties on Record
$1,880
Site Address
6800 Industrial Blvd, Galveston, TX 77553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
Flammable Liquids
OSHA citation code: 19100106 G03 IVC
Serious1-$640$640Feb 2, 1980--
01001B1910.309
OSHA citation code: 19100309 A 050104
Serious1-$0$0Feb 2, 1980--
010021910.180
Crawler Locomotive and Truck Cranes
OSHA citation code: 19100180 H04 I
Serious1-$100$100Feb 2, 1980--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious4-$400$400Apr 14, 1980--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 I02
Serious4-$100$100Feb 26, 1980--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 10 of 17, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection9 citations · $936
1910.95Occupational Noise Exposure8 citations · $1,992
1915.152General Requirements (PPE)5 citations · $1,314

Chemical exposure sampling

Samples
35
Substances
15
Inspections
1

Other inspected employers in Galveston, TX

All employers in Galveston →