Skip to content
SafetyRecord logoSafetyRecord
GASKETS INC
$1,869
penalties
33
viol.
7
insp.

GASKETS INC

PO BOX 368, Rio, WI 53960

Inspections
7
Jan 1974 to Jan 2003 · 2 safety, 5 health
Violations
33
across 7 inspections
Penalties on record
$1,869
latest amounts in DOL records
By classification
Serious 17Willful 0Repeat 0Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 28, 2003Planned (H) · Partial scope, Health#306104464$6848 viol.

Inspection #306104464

Dates

Opened
Jan 28, 2003
Closing Conference Date
Feb 20, 2003
Closed
Jun 9, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
8
Violation Types
8 serious
Initial Penalties
$975
Penalties on Record
$684
Site Address
Hwy. 16, Rio, WI 53960
Industry
339991 Gasket, Packing, and Sealing Device Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious43$225$158Apr 9, 2003--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious13$225$158Apr 9, 2003--
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious23$0$0Mar 25, 2003--
01003A1910.1025
Lead
OSHA citation code: 19101025 D02
Serious13$300$210Apr 9, 2003--
01003B1910.1025
Lead
OSHA citation code: 19101025 L01 I
Serious23$0$0Mar 19, 2003--
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Serious13$225$158Mar 25, 2003--
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious33$0$0Mar 20, 2003--

Showing the 7 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 23, 1998Planned (H) · Complete scope, Safety#300565306$1,00011 viol.

Inspection #300565306

Dates

Opened
Mar 23, 1998
Closing Conference Date
Mar 23, 1998
Closed
Jun 30, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
25

Violations and Penalties

Total Violations
11
Violation Types
8 serious, 3 other-than-serious
Initial Penalties
$1,950
Penalties on Record
$1,000
Site Address
Hwy. 16, Rio, WI 53960
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$750$400May 8, 1998--
01001B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious21$0$0May 8, 1998--
01001C1910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C01
Serious21$0$0Apr 14, 1998--
01002A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious12$600$300Jun 30, 1998--
01002B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious11$0$0Apr 11, 1998--
01003A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious62$600$300Apr 14, 1998--
01003B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious12$0$0May 8, 1998--

Showing the 7 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 2, 1991Complaint (B) · Complete scope, Health#102515749$1603 viol.

Inspection #102515749

Dates

Opened
Jan 2, 1991
Closing Conference Date
Jan 24, 1991
Closed
Apr 1, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
38
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$160
Penalties on Record
$160
Site Address
Hwy. 16, Rio, WI 53960
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling21 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone140 - 4.6231ppm
Acetone60 - 219.116ppm
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.0227mg/m³
Ethyl Benzene20 - 0.2205ppm
Iron Oxide Fume20 - 2.5448mg/m³
Isopropyl Acetate20.1259 - 12.3033ppm
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20 - 0.2034mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
n-Butyl Acetate20ppm
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Stoddard Solvent20mg/m³
Toluene20 - 17.213ppm
Vanadium fume (as V2O5)20mg/m³
Xylene20 - 0.6013ppm
Zinc Oxide Fume20 - 0.026mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious13$160$160Feb 28, 1991--
020011910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other138$0$0Feb 1, 1991--
020021910.94
Ventilation
OSHA citation code: 19100094 C04 IV
Other13$0$0Apr 29, 1991--
Oct 21, 1985Programmed Related (I) · Partial scope, Health#1321918$02 viol.

Inspection #1321918

Dates

Opened
Oct 21, 1985
Closing Conference Date
Nov 18, 1985
Closed
Dec 30, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
17

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hy-16 West, Rio, WI 53960
Industry
Not classified in OSHA's inspection record.

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Asbestos (all forms)40 - 0.04f/cc

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1001
Asbestos
OSHA citation code: 19101001 H01
Other14$0$0Jan 6, 1986--
010021910.20
Access to Employee Exposure and Medical Records
OSHA citation code: 19100020 G01 I
Other14$0$0Dec 9, 1985--
Oct 4, 1977Planned (H) · Partial scope, Health#15454671$03 viol.

Inspection #15454671

Dates

Opened
Oct 4, 1977
Closing Conference Date
Oct 4, 1977
Closed
Jan 6, 1978

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
8

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Po Box 368 Hwy 16, Rio, WI 53960
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1001
Asbestos
OSHA citation code: 19101001 G02 I
Other1-$0$0Jan 10, 1978--
010021910.1001
Asbestos
OSHA citation code: 19101001 J02
Other1-$0$0Dec 26, 1977--
010031910.1001
Asbestos
OSHA citation code: 19101001 J04
Other1-$0$0Dec 26, 1977--
Nov 16, 1976Planned (H) · Complete scope, Safety#15550502$05 viol.

Inspection #15550502

Dates

Opened
Nov 16, 1976
Closing Conference Date
Nov 16, 1976
Closed
Feb 23, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Po Box 368 Hwy 16, Rio, WI 53960
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Other1-$0$0Feb 17, 1977--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other1-$0$0Dec 17, 1976--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 I
Other1-$0$0Jan 17, 1977--
010041910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 III
Other1-$0$0Jan 17, 1977--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other1-$0$0Dec 17, 1976--
Jan 10, 1974Planned (H) · Partial scope, Health#15562945$251 viol.

Inspection #15562945

Dates

Opened
Jan 10, 1974
Closing Conference Date
Jan 10, 1974
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
10

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$25
Penalties on Record
$25
Site Address
Po Box 368, Rio, WI 53960
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1000
Air Contaminants
OSHA citation code: 19101000 A
Other4-$25$25Sep 1, 1974--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)4 citations · $560
1910.1001Asbestos4 citations · $0
1910.1200Hazard Communication3 citations · $158

Chemical exposure sampling

Samples
61
Substances
22
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

BLS 2024 survey: gasket, packing, and sealing device manufacturing reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 20.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Rio, WI