Skip to content
SafetyRecord logoSafetyRecord
GE JOHNSON CONSTRUCTION COMPANY, INC.
$8,468
penalties
9
viol.
16
insp.

GE JOHNSON CONSTRUCTION COMPANY, INC.

2525 S. HWY 115, Colorado Springs, CO 80906NAICS 236220 Commercial and Institutional Building Construction

Inspections
16
Apr 1991 to Jul 2015 · 15 safety, 1 health
Violations
9
across 16 inspections
Penalties on record
$8,468
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 1, 1999Referral (C) · Partial scope, Safety#302309166$00 viol.

Inspection #302309166

Dates

Opened
Apr 1, 1999
Closing Conference Date
Apr 1, 1999
Closed
Apr 9, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
3030 N. Circle Dr., Colorado Springs, CO 80906
Industry
236220 Commercial and Institutional Building Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Oct 9, 1992Complaint (B) · Partial scope, Safety#109549410$1,2183 viol.

Inspection #109549410

Dates

Opened
Oct 9, 1992
Closing Conference Date
Oct 13, 1992
Closed
Jan 13, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$1,875
Penalties on Record
$1,218
Site Address
2525 S. Hwy 115, Colorado Springs, CO 80906
Industry
236220 Commercial and Institutional Building Construction

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious11$1,125$731Dec 13, 1992--
01001B1926.350
Gas Welding and Cutting
OSHA citation code: 19260350 G03
Serious11$0$0Dec 13, 1992--
020011926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 B08
Other62$750$487Dec 13, 1992--
Apr 29, 1992Planned (H) · Partial scope, Safety#100576347$5,5002 viol.

Inspection #100576347

Dates

Opened
Apr 29, 1992
Closing Conference Date
Apr 30, 1992
Contested
Jul 2, 1992
Final Order
May 3, 1993
Closed
May 25, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$7,500
Penalties on Record
$5,500
Site Address
705 S Nevada, Colorado Springs, CO 80903
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.105
Safety Nets
OSHA citation code: 19260105 A
Serious11$3,500$3,500Mar 1, 1993Jul 2, 1992May 3, 1993
010031926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 D01
Serious11$4,000$2,000Mar 1, 1993Jul 2, 1992May 3, 1993
Feb 6, 1992Unprogrammed Related (G) · Partial scope, Safety#100576065$00 viol.

Inspection #100576065

Dates

Opened
Feb 6, 1992
Closing Conference Date
Feb 6, 1992
Closed
Mar 10, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
110 E. Monroe, Colorado Springs, CO 80907
Industry
236220 Commercial and Institutional Building Construction

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

May 3, 1991Planned (H) · No Inspection scope, Safety#100571728$00 viol.

Inspection #100571728

Dates

Opened
May 3, 1991
Closing Conference Date
May 3, 1991
Closed
May 3, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
90 South Cascade, Colorado Springs, CO 80903
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 18, 1991Planned (H) · Complete scope, Safety#100676154$2501 viol.

Inspection #100676154

Dates

Opened
Apr 18, 1991
Closing Conference Date
Apr 18, 1991
Contested
Jun 4, 1991
Final Order
Oct 28, 1991
Closed
Oct 22, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$250
Site Address
4250 Cheyenne Mountain Zoo Road, Colorado Springs, CO 80904
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIJ
Other1-$1,000$250May 14, 1991Jun 4, 1991Oct 28, 1991
Inspections 11 to 16 of 16, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.403Electrical - General Requirements (Construction)2 citations · $1,500
1926.405Electrical - Wiring Methods (Construction)2 citations · $250
1926.500Scope, application, and definitions applicable to this subpart2 citations · $2,487

Industry comparison

Violations per inspection
This employer0.6
Industry average1.5
Penalties per inspection
This employer$529
Industry average$1,287

Construction of Buildings, 202,795 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Colorado Springs, CO

All employers in Colorado Springs →