GENERAL SPLIT CORPORATION
1113 MARYLAND AVE, SHEBOYGAN, WI 53081
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 12, 1990#103054128Oct 12, 1990Planned (H) · No Inspection scope, Safety#103054128$00 viol.0 violations$0 in penalties
Inspection #103054128
Dates
- Opened
- Oct 12, 1990
- Closing Conference Date
- Oct 12, 1990
- Closed
- Oct 12, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1031 Maryland, Sheboygan, WI 53082
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jan 28, 1986#100111384Jan 28, 1986Referral (C) · Complete scope, Safety#100111384$6010 viol.10 violations$60 in penalties
Inspection #100111384
Dates
- Opened
- Jan 28, 1986
- Closing Conference Date
- Jan 28, 1986
- Closed
- Apr 21, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 105
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 1 serious, 9 other-than-serious
- Initial Penalties
- $160
- Penalties on Record
- $60
- Site Address
- 1031 Maryland Ave., Sheboygan, WI 53082
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A04 | Serious | 5 | 4 | $160 | $60 | May 12, 1986 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 B01 | Other | 1 | 1 | $0 | $0 | Feb 18, 1986 | - | - |
| 02002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Other | 2 | 2 | $0 | $0 | Apr 11, 1986 | - | - |
| 02003 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Other | 1 | 1 | $0 | $0 | Mar 26, 1986 | - | - |
| 02004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 8 | 4 | $0 | $0 | May 12, 1986 | - | - |
| 02005A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 2 | 2 | $0 | $0 | Apr 11, 1986 | - | - |
| 02005B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Other | 2 | 2 | $0 | $0 | Apr 11, 1986 | - | - |
| 02006 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Other | 1 | 2 | $0 | $0 | May 12, 1986 | - | - |
| 02007 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Other | 1 | 1 | $0 | $0 | Feb 18, 1986 | - | - |
| 02008 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A04 IV | Other | 1 | 2 | $0 | $0 | Feb 18, 1986 | - | - |
Dec 18, 1985#100114024Dec 18, 1985Complaint (B) · Complete scope, Health#100114024$02 viol.2 violations$0 in penalties
Inspection #100114024
Dates
- Opened
- Dec 18, 1985
- Closing Conference Date
- Jan 14, 1986
- Closed
- Sep 19, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 105
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1031 Maryland Ave., Sheboygan, WI 53082
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling16 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 1 | 0 | mg/m³ |
| Chromic Acid and Chromates (as CrO3) | 1 | 0.0037 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 2 | 0.0064 - 0.0823 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1 | 0 | mg/m³ |
| Copper Fume (as Cu) | 1 | 0.0209 | mg/m³ |
| Iron Oxide Fume | 1 | 0.0231 | mg/m³ |
| Lead, Inorganic (as Pb) | 1 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 1 | 0.049 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 1 | 2.684 | mg/m³ |
| Vanadium fume (as V2O5) | 1 | 0 | mg/m³ |
| Zinc Oxide Fume | 1 | 0.01 | mg/m³ |
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Other | 8 | 15 | $0 | $0 | Jun 30, 1986 | - | - |
| 01002 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 I02 IIA | Other | 4 | 10 | $0 | $0 | Jan 30, 1986 | - | - |
Jan 9, 1985#1690296Jan 9, 1985Planned (H) · No Inspection scope, Safety#1690296$00 viol.0 violations$0 in penalties
Inspection #1690296
Dates
- Opened
- Jan 9, 1985
- Closing Conference Date
- Not recorded
- Closed
- Jan 11, 1985
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1113 Maryland Ave, Sheboygan, WI 53081
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1985 to 1990. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.