Jan 17, 2013#338368053Jan 17, 2013Planned (H) · Partial scope, Safety#338368053$5,4007 viol.7 violations$5,400 in penalties
Inspection #338368053
Dates
- Opened
- Jan 17, 2013
- Closing Conference Date
- Jan 17, 2013
- Final Order
- Apr 19, 2013
- Closed
- Apr 26, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 6 serious, 1 other-than-serious
- Initial Penalties
- $7,200
- Penalties on Record
- $5,400
- Site Address
- 114 Chambersburg Street, Gettysburg, PA 17325
- Industry
- 236116 New Multifamily Housing Construction (except For-Sale Builders)
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 II B | Serious | 1 | 4 | $1,600 | $1,200 | May 7, 2013 | - | Apr 19, 2013 |
| 01002A | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 II E | Serious | 1 | 4 | $1,600 | $1,200 | May 7, 2013 | - | Apr 19, 2013 |
| 01002B | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 A02 II F | Serious | 1 | 4 | $0 | $0 | May 7, 2013 | - | Apr 19, 2013 |
| 01003 | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B13 | Serious | 1 | 4 | $2,000 | $1,500 | May 7, 2013 | - | Apr 19, 2013 |
| 01004A | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B04 | Serious | 1 | 4 | $2,000 | $1,500 | May 7, 2013 | - | Apr 19, 2013 |
| 01004B | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B13 | Serious | 1 | 2 | $0 | $0 | May 7, 2013 | - | Apr 19, 2013 |
| 02001 | 1926.416 Electrical - Safety Requirements (Construction) OSHA citation code: 19260416 E02 | Other | 1 | 4 | $0 | $0 | May 7, 2013 | - | Apr 19, 2013 |
Nov 23, 2011#113740971Nov 23, 2011Planned (H) · No Inspection scope, Safety#113740971$00 viol.0 violations$0 in penalties
Inspection #113740971
Dates
- Opened
- Nov 23, 2011
- Closing Conference Date
- Nov 23, 2011
- Closed
- Nov 23, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Not recorded
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 125 Sourth Washington Street, Gettysburg, PA 17325
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Feb 10, 2000#112658901Feb 10, 2000Planned (H) · Complete scope, Safety#112658901$2,1616 viol.6 violations$2,161 in penalties
Inspection #112658901
Dates
- Opened
- Feb 10, 2000
- Closing Conference Date
- Feb 10, 2000
- Closed
- Feb 24, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 6
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 5 serious, 1 other-than-serious
- Initial Penalties
- $3,325
- Penalties on Record
- $2,161
- Site Address
- 606 York Street, Gettysburg, PA 17325
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 H10 | Serious | 1 | 10 | $1,225 | $796 | Feb 18, 2000 | - | - |
| 01001B | 1926.416 Electrical - Safety Requirements (Construction) OSHA citation code: 19260416 B02 | Serious | 1 | 10 | $0 | $0 | Mar 13, 2000 | - | - |
| 01002 | 1926.153 Liquefied Petroleum Gas (LP-Gas) OSHA citation code: 19260153 H13 | Serious | 1 | 10 | $1,225 | $796 | Mar 13, 2000 | - | - |
| 01003A | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B10 | Serious | 1 | 3 | $875 | $569 | Feb 18, 2000 | - | - |
| 01003B | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B02 | Serious | 1 | 13 | $0 | $0 | Mar 13, 2000 | - | - |
| 02001 | 1926.1053 Ladders (Construction) OSHA citation code: 19261053 B01 | Other | 1 | 3 | $0 | $0 | Mar 13, 2000 | - | - |
Aug 19, 1997#116156845Aug 19, 1997Planned (H) · Complete scope, Safety#116156845$03 viol.3 violations$0 in penalties
Inspection #116156845
Dates
- Opened
- Aug 19, 1997
- Closing Conference Date
- Aug 19, 1997
- Closed
- Aug 28, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 4
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- York & Stratton Streets, Gettysburg, PA 17325
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 B02 | Other | 1 | 3 | $0 | $0 | Sep 5, 1997 | - | - |
| 01002 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 F07 IVC | Other | 1 | 3 | $0 | $0 | Sep 5, 1997 | - | - |
| 01003 | 1926.404 Electrical - Wiring Design and Protection (Construction) OSHA citation code: 19260404 B01 I | Other | 1 | 3 | $0 | $0 | Sep 5, 1997 | - | - |
Nov 30, 1982#12574539Nov 30, 1982Planned (H) · Complete scope, Safety#12574539$01 viol.1 violation$0 in penalties
Inspection #12574539
Dates
- Opened
- Nov 30, 1982
- Closing Conference Date
- Nov 30, 1982
- Closed
- Feb 7, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 211 N 4th St, Gettysburg, PA 17325
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1903.2 Posting of Notices; Availability of the Act, Regulations and Applicable Standards OSHA citation code: 19030002 A01 | Other | 1 | - | $0 | $0 | Dec 24, 1982 | - | - |
Jul 6, 1982#12536306Jul 6, 1982Planned (H) · Complete scope, Safety#12536306$00 viol.0 violations$0 in penalties
Inspection #12536306
Dates
- Opened
- Jul 6, 1982
- Closing Conference Date
- Jul 6, 1982
- Closed
- Jul 13, 1982
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Meadows Drive Rd 6, Gettysburg, PA 17325
- Industry
- 236220 Commercial and Institutional Building Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1982 to 2013. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Construction of Buildings, 202,614 employers with OSHA inspections. Arithmetic from DOL records.