Skip to content
SafetyRecord logoSafetyRecord
GRENIER CONSTRUCTION CO. INC. OF SHREWSBURY
$5,000
penalties
11
viol.
1
insp.

GRENIER CONSTRUCTION CO. INC. OF SHREWSBURY

QUARRY RD., MILFORD, MA 01757NAICS 238120 Structural Steel and Precast Concrete Contractors

Inspections
1
Aug 2006 to Aug 2006 · 1 safety, 0 health
Violations
11
across 1 inspection
Penalties on record
$5,000
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 1, 2006Referral (C) · Partial scope, Safety#308353960$5,00011 viol.

Inspection #308353960

Dates

Opened
Aug 1, 2006
Closing Conference Date
Aug 29, 2006
Closed
Oct 11, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 referral

Violations and Penalties

Total Violations
11
Violation Types
11 serious
Initial Penalties
$6,000
Penalties on Record
$5,000
Site Address
Quarry Rd., Milford, MA 01757
Industry
238120 Structural Steel and Precast Concrete Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C01 II
Serious16$375$275Oct 2, 2006--
010021926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C04
Serious18$375$275Oct 2, 2006--
010031926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W01
Serious11$375$275Oct 2, 2006--
010041926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W02
Serious16$375$275Nov 7, 2006--
010051926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W07
Serious11$375$275Oct 2, 2006--
010061926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W08
Serious11$375$275Oct 10, 2006--
010071926.754
Steel Erection - Structural Steel Assembly
OSHA citation code: 19260754 E02
Serious18$375$275Sep 26, 2006--
010081926.760
Steel Erection - Fall Protection
OSHA citation code: 19260760 C03
Serious17$375$275Oct 2, 2006--
010091926.760
Steel Erection - Fall Protection
OSHA citation code: 19260760 C04
Serious18$1,500$1,400Oct 10, 2006--
01010A1926.760
Steel Erection - Fall Protection
OSHA citation code: 19260760 A01
Serious17$1,500$1,400Sep 25, 2006--
01010B1926.760
Steel Erection - Fall Protection
OSHA citation code: 19260760 C07
Serious18$0$0Oct 2, 2006--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.452Additional Requirements for Specific Scaffold Types5 citations · $1,375
1926.760Steel Erection - Fall Protection4 citations · $3,075
1926.451Scaffolding - General Requirements1 citation · $275

Industry comparison

Violations per inspection
This employer11.0
Industry average2.1
Penalties per inspection
This employer$5,000
Industry average$2,541

Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: structural steel and precast concrete contractors reported 2.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.9%; NAICS 23812 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in MILFORD, MA