HAGERMAN INC
(WALGREENS) 6201 STELLHORN RD, FORT WAYNE, IN 46815
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
May 30, 2024#347516494May 30, 2024Unprogrammed Related (G) · Partial scope, Safety#347516494$00 viol.0 violations$0 in penalties
Inspection #347516494
Dates
- Opened
- May 30, 2024
- Closing Conference Date
- Jun 21, 2024
- Closed
- Jul 25, 2024
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 14
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 9100 Winchester Rd., Fort Wayne, Fort Wayne, IN 46808
- Industry
- 238140 Masonry Contractors
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Apr 6, 2004#306868894Apr 6, 2004Planned (H) · Complete scope, Safety#306868894$02 viol.2 violations$0 in penalties
Inspection #306868894
Dates
- Opened
- Apr 6, 2004
- Closing Conference Date
- Apr 16, 2004
- Closed
- Aug 19, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4027 Hathaway Road, Fort Wayne, IN 46818
- Industry
- 238350 Finish Carpentry Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01003 | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 C01 VIII | Other | 1 | 2 | $0 | $0 | Jul 30, 2004 | - | - |
| 01004 | 1926.416 Electrical - Safety Requirements (Construction) OSHA citation code: 19260416 E01 | Other | 1 | 2 | $0 | $0 | Jul 30, 2004 | - | - |
Apr 16, 2002#305194896Apr 16, 2002Planned (H) · Complete scope, Safety#305194896$01 viol.1 violation$0 in penalties
Inspection #305194896
Dates
- Opened
- Apr 16, 2002
- Closing Conference Date
- Apr 17, 2002
- Closed
- Sep 24, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 15
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Southwest Allen Elementary School, Fort Wayne, IN 46804
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Other | 1 | 15 | $0 | $0 | Sep 3, 2002 | - | - |
Aug 13, 1997#125331934Aug 13, 1997Planned (H) · Partial scope, Safety#125331934$00 viol.0 violations$0 in penalties
Inspection #125331934
Dates
- Opened
- Aug 13, 1997
- Closing Conference Date
- Aug 13, 1997
- Closed
- Aug 25, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 11
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- (scott Foods Number 15) 4522 Maplecrest Road, Fort Wayne, IN 46835
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jan 9, 1995#124026444Jan 9, 1995Planned (H) · Complete scope, Safety#124026444$01 viol.1 violation$0 in penalties
Inspection #124026444
Dates
- Opened
- Jan 9, 1995
- Closing Conference Date
- Jan 19, 1995
- Contested
- Apr 7, 1995
- Final Order
- Feb 9, 1996
- Closed
- Feb 22, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- (the Towne House) 2209 Saint Joe Center Rd, Fort Wayne, IN 46825
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 02001 | 1926.352 Fire Prevention (Welding) OSHA citation code: 19260352 D | Other | 1 | 1 | $0 | $0 | Mar 20, 1995 | Apr 7, 1995 | Feb 9, 1996 |
Aug 17, 1993#124023235Aug 17, 1993Planned (H) · Complete scope, Safety#124023235$03 viol.3 violations$0 in penalties
Inspection #124023235
Dates
- Opened
- Aug 17, 1993
- Closing Conference Date
- Sep 7, 1993
- Closed
- Oct 8, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 13
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- (walgreens) 6201 Stellhorn Rd, Fort Wayne, IN 46815
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A01 | Other | 1 | 1 | $0 | $0 | Oct 12, 1993 | - | - |
| 01002 | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 H | Other | 1 | - | $0 | $0 | Oct 12, 1993 | - | - |
| 01003 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 B01 | Other | 1 | 6 | $0 | $0 | Oct 12, 1993 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1993 to 2024. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.