Skip to content
SafetyRecord logoSafetyRecord
HAR-SON MFG., INC
$1,590
penalties
26
viol.
3
insp.

HAR-SON MFG., INC

26-30 MECHANIC STREET, SILVER CREEK, NY 14136

Inspections
3
Nov 1988 to Apr 1992 · 2 safety, 1 health
Violations
26
across 3 inspections
Penalties on record
$1,590
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 0Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 29, 1992Planned (H) · No Inspection scope, Safety#107344277$00 viol.

Inspection #107344277

Dates

Opened
Apr 29, 1992
Closing Conference Date
Apr 29, 1992
Closed
Apr 29, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
26-30 Mechanic Street, Silver Creek, NY 14136
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Mar 3, 1989Planned (H) · Complete scope, Safety#106919186$84016 viol.

Inspection #106919186

Dates

Opened
Mar 3, 1989
Closing Conference Date
Mar 6, 1989
Closed
Sep 7, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
16
Violation Types
7 serious, 9 other-than-serious
Initial Penalties
$840
Penalties on Record
$840
Site Address
26-30 Mechanic Street, Silver Creek, NY 14136
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious21$320$320Jun 1, 1989--
01001B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 D01
Serious11$0$0Mar 23, 1989--
01002A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious36$240$240Apr 7, 1989--
01002B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious24$0$0Mar 31, 1989--
01002C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious12$0$0Mar 31, 1989--
01003A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious22$280$280Jun 1, 1989--
01003B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious12$0$0Jun 1, 1989--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Other14$0$0Mar 31, 1989--
020021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other14$0$0Mar 31, 1989--
020031910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other11$0$0Apr 7, 1989--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other110$0$0Jun 1, 1989--
020051910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other210$0$0Jun 1, 1989--
020061910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other12$0$0Mar 31, 1989--
020071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other12$0$0Jun 1, 1989--
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other11$0$0Jun 1, 1989--
020091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other11$0$0Mar 31, 1989--
Nov 4, 1988Planned (H) · Complete scope, Health#100650555$75010 viol.

Inspection #100650555

Dates

Opened
Nov 4, 1988
Closing Conference Date
Dec 27, 1988
Closed
Jun 20, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
10
Violation Types
3 serious, 7 other-than-serious
Initial Penalties
$1,280
Penalties on Record
$750
Site Address
26-30 Mechanic Street, Silver Creek, NY 14136
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40.0441 - 0.0653mg/m³
Iron Oxide Fume40.0185 - 0.1036mg/m³
Lead, Inorganic (as Pb)40.0361 - 0.2778mg/m³
Manganese Fume (as Mn)40mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40 - 0.0169mg/m³
Particulates not otherwise regulated (Respirable Fraction)40mg/m³
Particulates not otherwise regulated (Total Dust)20.785 - 1.001mg/m³
Silica, Crystalline Quartz (Respirable Fraction)23.4 - 4%
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40.0421 - 2.4054mg/m³

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1025
Lead
OSHA citation code: 19101025 C01
Serious22$640$375Jan 24, 1989--
01001B1910.1025
Lead
OSHA citation code: 19101025 F02 III
Serious22$0$0Jan 24, 1989--
010021910.1025
Lead
OSHA citation code: 19101025 J03 IA
Serious11$640$375Feb 7, 1989--
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other24$0$0Mar 9, 1989--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other316$0$0Jan 8, 1989--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other316$0$0Jan 8, 1989--
02004A1910.1025
Lead
OSHA citation code: 19101025 I02 I
Other12$0$0Apr 10, 1989--
02004B1910.1025
Lead
OSHA citation code: 19101025 I02 II
Other22$0$0Apr 10, 1989--
02004C1910.1025
Lead
OSHA citation code: 19101025 I03 I
Other22$0$0Apr 10, 1989--
02004D1910.1025
Lead
OSHA citation code: 19101025 I03 II
Other22$0$0Apr 10, 1989--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead7 citations · $750
1910.305Electrical - Wiring Methods, Components, and Equipment6 citations · $280
1910.303Electrical - General Requirements3 citations · $0

Chemical exposure sampling

Samples
60
Substances
16
Inspections
1

Other inspected employers in SILVER CREEK, NY