Skip to content
SafetyRecord logoSafetyRecord
IVESTER, INC.
$360
penalties
17
viol.
13
insp.

IVESTER, INC.

BOILING SPRINGS ROAD, GREENVILLE, SC 29672

Inspections
13
Mar 1991 to Apr 2005 · 13 safety, 0 health
Violations
17
across 13 inspections
Penalties on record
$360
latest amounts in DOL records
By classification
Serious 1Willful 0Repeat 0Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 9, 1992Planned (H) · Complete scope, Safety#115683898$02 viol.

Inspection #115683898

Dates

Opened
Jan 9, 1992
Closing Conference Date
Jan 9, 1992
Closed
Jan 21, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
E. Faris & S. Pleasantburg, Greenville, SC 29606
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
030011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E04
Other11$0$0Jan 20, 1992--
030021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E08
Other21$0$0Jan 20, 1992--
Dec 9, 1991Planned (H) · Complete scope, Safety#115683773$3601 viol.

Inspection #115683773

Dates

Opened
Dec 9, 1991
Closing Conference Date
Dec 9, 1991
Closed
Feb 7, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$900
Penalties on Record
$360
Site Address
529 Farrs Bridge Rd., Greenville, SC 29611
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious11$900$360Jan 2, 1992--
Mar 28, 1991Planned (H) · Complete scope, Safety#111037651$06 viol.

Inspection #111037651

Dates

Opened
Mar 28, 1991
Closing Conference Date
Mar 28, 1991
Closed
May 29, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
6
Violation Types
6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Boiling Springs Road, Greenville, SC 29672
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
050011926.50
Medical services and first aid
OSHA citation code: 19260050 C
Other12$0$0Jun 26, 1991--
05002A1926.59
Hazard Communication
OSHA citation code: 19260059 E01
Other12$0$0Apr 27, 1991--
05002B1926.59
Hazard Communication
OSHA citation code: 19260059 E01
Other12$0$0Apr 27, 1991--
05002C1926.59
Hazard Communication
OSHA citation code: 19260059 E02
Other158$0$0Apr 27, 1991--
05002D1926.59
Hazard Communication
OSHA citation code: 19260059 G01
Other22$0$0May 28, 1991--
05002E1926.59
Hazard Communication
OSHA citation code: 19260059 H
Other12$0$0May 28, 1991--
Inspections 11 to 13 of 13, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.59Hazard Communication5 citations · $0
1926.451Scaffolding - General Requirements2 citations · $0
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $360

Industry comparison

BLS 2024 survey: plumbing, heating, and air-conditioning contractors reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.2%; NAICS 23822 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GREENVILLE, SC

All employers in GREENVILLE →