J & K PAINTING CORP.
BRONX RIVER PARKWAY - MIDLAND AVENUE BRIDGE, Bronxville, NY 10708
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 2, 1999#302801972Sep 2, 1999Referral (C) · Partial scope, Health#302801972$10,24025 viol.25 violations$10,240 in penalties
Inspection #302801972
Dates
- Opened
- Sep 2, 1999
- Closing Conference Date
- Sep 2, 1999
- Closed
- Jan 26, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 8
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 25
- Violation Types
- 24 serious, 1 other-than-serious
- Initial Penalties
- $15,750
- Penalties on Record
- $10,240
- Site Address
- Bronx River Parkway - Midland Avenue Bridge, Bronxville, NY 10708
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling12 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 7 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 7 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 7 | 0 - 0.0036 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 7 | 0 - 0.0015 | mg/m³ |
| Copper Fume (as Cu) | 7 | 0 - 0.0063 | mg/m³ |
| Iron Oxide Fume | 7 | 0.0734 - 4.7952 | mg/m³ |
| Lead, Inorganic (as Pb) | 7 | 0.0912 - 5.4802 | mg/m³ |
| Manganese Fume (as Mn) | 7 | 0.00095 - 0.0192 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 7 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 7 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 7 | 0 | mg/m³ |
| Zinc Oxide Fume | 7 | 0.006 - 0.3139 | mg/m³ |
Violations
Violation list (25 of 25 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 D01 II | Serious | 1 | 1 | $1,500 | $975 | Mar 9, 2000 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 III | Serious | 1 | 5 | $0 | $0 | Mar 9, 2000 | - | - |
| 01001C | 1910.134 Respiratory Protection OSHA citation code: 19100134 K05 II | Serious | 1 | 5 | $0 | $0 | Mar 9, 2000 | - | - |
| 01001D | 1926.62 Lead OSHA citation code: 19260062 C01 | Serious | 2 | 4 | $0 | $0 | Apr 13, 2000 | - | - |
| 01001E | 1926.62 Lead OSHA citation code: 19260062 E01 | Serious | 2 | 4 | $0 | $0 | Apr 13, 2000 | - | - |
| 01001F | 1926.62 Lead OSHA citation code: 19260062 E03 | Serious | 2 | 4 | $0 | $0 | Apr 13, 2000 | - | - |
| 01001G | 1926.62 Lead OSHA citation code: 19260062 F03 I | Serious | 1 | 1 | $0 | $0 | Mar 9, 2000 | - | - |
| 01002 | 1926.62 Lead OSHA citation code: 19260062 E02 I | Serious | 1 | 4 | $1,500 | $975 | Apr 13, 2000 | - | - |
| 01003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Serious | 1 | 1 | $450 | $293 | Mar 29, 2000 | - | - |
| 01004 | 1910.134 Respiratory Protection OSHA citation code: 19100134 H01 I | Serious | 1 | 5 | $1,500 | $975 | Mar 4, 2000 | - | - |
| 01005 | 1926.62 Lead OSHA citation code: 19260062 D06 III | Serious | 1 | 5 | $750 | $488 | Mar 1, 2000 | - | - |
| 01006 | 1926.62 Lead OSHA citation code: 19260062 G01 II | Serious | 1 | 4 | $750 | $488 | Mar 29, 2000 | - | - |
| 01007 | 1926.62 Lead OSHA citation code: 19260062 I03 I | Serious | 1 | 4 | $1,500 | $975 | Mar 29, 2000 | - | - |
| 01008A | 1926.62 Lead OSHA citation code: 19260062 I04 II | Serious | 1 | 4 | $1,500 | $975 | Mar 4, 2000 | - | - |
| 01008B | 1926.62 Lead OSHA citation code: 19260062 I04 III | Serious | 1 | 4 | $0 | $0 | Mar 4, 2000 | - | - |
| 01008C | 1926.62 Lead OSHA citation code: 19260062 I04 IV | Serious | 1 | 4 | $0 | $0 | Mar 4, 2000 | - | - |
| 01009 | 1926.62 Lead OSHA citation code: 19260062 J01 I | Serious | 1 | 3 | $1,500 | $975 | Mar 29, 2000 | - | - |
| 01010 | 1926.62 Lead OSHA citation code: 19260062 J02 III | Serious | 1 | 4 | $1,500 | $975 | Mar 29, 2000 | - | - |
| 01011 | 1926.62 Lead OSHA citation code: 19260062 M02 I | Serious | 1 | 4 | $750 | $488 | Mar 4, 2000 | - | - |
| 01012 | 1926.102 Eye and face protection OSHA citation code: 19260102 A01 | Serious | 2 | 6 | $750 | $488 | Mar 9, 2000 | - | - |
| 01013A | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 A04 | Serious | 1 | 6 | $600 | $390 | Mar 14, 2000 | - | - |
| 01013B | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 C01 VIII | Serious | 1 | 7 | $0 | $0 | Mar 14, 2000 | - | - |
| 01014 | 1926.152 OSHA citation code: 19260152 E02 | Serious | 2 | 7 | $600 | $390 | Mar 14, 2000 | - | - |
| 01015 | 1926.152 OSHA citation code: 19260152 F01 | Serious | 2 | 7 | $600 | $390 | Mar 14, 2000 | - | - |
| 02001 | 1926.416 Electrical - Safety Requirements (Construction) OSHA citation code: 19260416 E01 | Other | 1 | 2 | $0 | $0 | Mar 14, 2000 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.