Skip to content
SafetyRecord logoSafetyRecord
J R STEEL SALES, INC.
$1,065
penalties
30
viol.
2
insp.

J R STEEL SALES, INC.

620 ST. CYR RD., Spanish Lake, MO 63137

Inspections
2
Jul 1990 to Jul 1990 · 1 safety, 1 health
Violations
30
across 2 inspections
Penalties on record
$1,065
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 31, 1990Complaint (B) · Partial scope, Health#106567274$69020 viol.

Inspection #106567274

Dates

Opened
Jul 31, 1990
Closing Conference Date
Oct 3, 1990
Contested
Nov 29, 1990
Final Order
Jun 13, 1991
Closed
Sep 3, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
2 complaints

Violations and Penalties

Total Violations
20
Violation Types
11 serious, 9 other-than-serious
Initial Penalties
$2,760
Penalties on Record
$690
Site Address
620 St. Cyr Rd., Spanish Lake, MO 63137
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)130mg/m³
Asbestos (all forms)40f/cc
Beryllium and Beryllium Compounds (as Be)130mg/m³
Cadmium Fume (as Cd)130mg/m³
Chromium, Metal and Insoluble Salts130 - 0.8375mg/m³
Cobalt, Metal, Dust and Fume (as Co)130mg/m³
Copper Fume (as Cu)130 - 22.4225mg/m³
Iron Oxide Fume131.38 - 13.5096mg/m³
Lead, Inorganic (as Pb)130mg/m³
Manganese Fume (as Mn)130 - 4.8882mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)130mg/m³
Nickel, Metal and Insoluble compounds (as Ni)130 - 2.675mg/m³
Vanadium fume (as V2O5)130 - 0.0083mg/m³
Zinc Oxide Fume130.0063 - 16.5732mg/m³

Violations

Violation list (20 of 20 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
OSHA citation code: 19100106 E06 I
Serious11$360$90May 15, 1991Nov 29, 1990Jun 13, 1991
01001B1910.106
OSHA citation code: 19100106 E06 II
Serious11$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
01001C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious11$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$300$75May 15, 1991Nov 29, 1990Jun 13, 1991
010031910.252
General requirements
OSHA citation code: 19100252 C01 III
Serious14$420$105May 15, 1991Nov 29, 1990Jun 13, 1991
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious14$420$105May 15, 1991Nov 29, 1990Jun 13, 1991
01004B1910.1000
Air Contaminants
OSHA citation code: 19101000 A03
Serious14$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
01004C1910.1000
Air Contaminants
OSHA citation code: 19101000 F02 I
Serious14$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
010051910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious15$420$105May 15, 1991Nov 29, 1990Jun 13, 1991
010061910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious15$420$105May 15, 1991Nov 29, 1990Jun 13, 1991
010071910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious15$420$105May 15, 1991Nov 29, 1990Jun 13, 1991
020011910.37
OSHA citation code: 19100037 B01
Other110$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other11$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
020031910.134
Respiratory Protection
OSHA citation code: 19100134 B02
Other11$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
020041910.252
General requirements
OSHA citation code: 19100252 B02 IA
Other14$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
020051910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D01
Other14$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
02006A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Other24$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
02006B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Other24$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
02006C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Other24$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
020071910.1001
Asbestos
OSHA citation code: 19101001 D02 I
Other110$0$0May 15, 1991Nov 29, 1990Jun 13, 1991
Jul 31, 1990Complaint (B) · Complete scope, Safety#101509982$37510 viol.

Inspection #101509982

Dates

Opened
Jul 31, 1990
Closing Conference Date
Jul 31, 1990
Contested
Aug 29, 1990
Closed
Jun 10, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
8 serious, 2 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$375
Site Address
620 St. Cyr Rd., Spanish Lake, MO 63137
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Enforcement Outcome

Citation contest activity appears on Aug 29, 1990. Final orders are recorded through Apr 1, 1991. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
OSHA citation code: 19100106 D02 I
Serious22$150$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Serious11$150$25Dec 7, 1990Aug 29, 1990Apr 1, 1991
010031910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 E02 I
Serious12$200$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
010041910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G05 IV
Serious12$200$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$150$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
010061910.252
General requirements
OSHA citation code: 19100252 A02 IIB
Serious112$250$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
010071910.252
General requirements
OSHA citation code: 19100252 F13
Serious110$250$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
010081910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious11$150$50Dec 7, 1990Aug 29, 1990Apr 1, 1991
020011910.38
OSHA citation code: 19100038 A01
Other112$0$0Sep 24, 1990Aug 29, 1990-
020021910.181
Derricks
OSHA citation code: 19100181 E01
Other21$0$0Aug 21, 1990Aug 29, 1990-
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.252General requirements4 citations · $205
1910.1000Air Contaminants4 citations · $0
1910.1200Hazard Communication3 citations · $315

Chemical exposure sampling

Samples
173
Substances
14
Inspections
1

Other inspected employers in Spanish Lake, MO

All employers in Spanish Lake →