Skip to content
SafetyRecord logoSafetyRecord
JAMIL PACKAGING
$850
penalties
23
viol.
5
insp.

JAMIL PACKAGING

1117 WEST SAMPLE, SOUTH BEND, IN 46619

Inspections
5
Mar 1981 to Oct 1998 · 5 safety, 0 health
Violations
23
across 5 inspections
Penalties on record
$850
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 29, 1998Planned (H) · Complete scope, Safety#125349365$67015 viol.

Inspection #125349365

Dates

Opened
Oct 29, 1998
Closing Conference Date
Nov 2, 1998
Closed
Apr 12, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
15
Violation Types
3 serious, 12 other-than-serious
Initial Penalties
$1,350
Penalties on Record
$670
Site Address
1117 West Sample, South Bend, IN 46619
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious1-$675$335Feb 19, 1999--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious16$675$335Mar 6, 1999--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious16$0$0Apr 2, 1999--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other12$0$0Mar 6, 1999--
020021910.25
Stairways
OSHA citation code: 19100025 D01 X
Other12$0$0Feb 19, 1999--
020031910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other150$0$0Mar 6, 1999--
020041910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other140$0$0Mar 6, 1999--
020051910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other12$0$0Apr 2, 1999--
020061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other16$0$0Mar 6, 1999--
020071910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other210$0$0Feb 19, 1999--

Showing the 10 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 13, 1989Planned (H) · Partial scope, Safety#108004912$904 viol.

Inspection #108004912

Dates

Opened
Oct 13, 1989
Closing Conference Date
Oct 13, 1989
Closed
Dec 28, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
55

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$120
Penalties on Record
$90
Site Address
1117 West Sample, South Bend, IN 46619
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious155$120$90Jan 16, 1990--
01001B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious155$0$0Jan 16, 1990--
01001C1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious155$0$0Jan 16, 1990--
01001D1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious155$0$0Jan 16, 1990--
Aug 8, 1984Planned (H) · Complete scope, Safety#14748115$01 viol.

Inspection #14748115

Dates

Opened
Aug 8, 1984
Closing Conference Date
Aug 13, 1984
Closed
Aug 27, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
54

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1117 W Sample St, South Bend, IN 46634
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B09
Other11$0$0Aug 27, 1984--
Dec 29, 1982Planned (H) · Complete scope, Safety#215170150$902 viol.

Inspection #215170150

Dates

Opened
Dec 29, 1982
Closing Conference Date
Dec 29, 1982
Closed
Feb 25, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$90
Penalties on Record
$90
Site Address
1117 West Sample St, South Bend, IN 46621
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious1-$90$90Feb 14, 1983--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious1-$0$0Feb 14, 1983--
Mar 23, 1981Complaint (B) · Partial scope, Safety#215360231$01 viol.

Inspection #215360231

Dates

Opened
Mar 23, 1981
Closing Conference Date
Mar 23, 1981
Closed
Apr 16, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
29
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1117 West Sample, South Bend, IN 46619
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other1-$0$0Apr 13, 1981--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication6 citations · $425
1910.178Powered Industrial Trucks3 citations · $0
1910.303Electrical - General Requirements3 citations · $0

Other inspected employers in SOUTH BEND, IN

All employers in SOUTH BEND →