Skip to content
SafetyRecord logoSafetyRecord
JIMMY RICHARDSON DBA PIEDMONT FRAMING & CARPENTRY
$2,300
penalties
11
viol.
3
insp.

JIMMY RICHARDSON DBA PIEDMONT FRAMING & CARPENTRY

4911 FOXCHASE RD., Greensboro, NC 27410NAICS 238130 Framing Contractors

Inspections
3
Apr 2006 to Mar 2009 · 2 safety, 1 health
Violations
11
across 3 inspections
Penalties on record
$2,300
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 2Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 12, 2009Planned (H) · Complete scope, Health#312197890$00 viol.

Inspection #312197890

Dates

Opened
Mar 12, 2009
Closing Conference Date
Mar 12, 2009
Closed
Apr 24, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1431 New Garden Road, Greensboro, NC 27410
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 15, 2007Planned (H) · Partial scope, Safety#310403761$1,6005 viol.

Inspection #310403761

Dates

Opened
May 15, 2007
Closing Conference Date
May 15, 2007
Closed
Jul 18, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 2 repeat, 2 other-than-serious
Initial Penalties
$5,600
Penalties on Record
$1,600
Site Address
4911 Foxchase Rd., Greensboro, NC 27410
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and face protection
OSHA citation code: 19260102 A01
Repeat11$5,250$1,300Jun 5, 2007--
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Repeat13$100$100Jun 5, 2007--
030011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious13$250$200Jun 5, 2007--
040011926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Other13$0$0Jun 26, 2007--
040021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Other12$0$0Jun 5, 2007--
Apr 4, 2006Planned (H) · Complete scope, Safety#309515294$7006 viol.

Inspection #309515294

Dates

Opened
Apr 4, 2006
Closing Conference Date
Apr 4, 2006
Closed
Jul 11, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
6
Violation Types
4 serious, 2 other-than-serious
Initial Penalties
$1,100
Penalties on Record
$700
Site Address
912 Sunset Drive, Greensboro, NC 27403
Industry
238130 Framing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious14$350$225Apr 26, 2006--
010021926.250
General Requirements for Storage
OSHA citation code: 19260250 B01
Serious15$250$150Apr 26, 2006--
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Serious14$150$100Apr 26, 2006--
010041926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious35$350$225Apr 26, 2006--
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Other15$0$0Apr 26, 2006--
020021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other15$0$0Apr 26, 2006--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $100
1926.102Eye and face protection2 citations · $1,525
1926.451Scaffolding - General Requirements2 citations · $100

Industry comparison

Violations per inspection
This employer3.7
Industry average2.1
Penalties per inspection
This employer$767
Industry average$2,531

Specialty Trade Contractors, 552,250 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: framing contractors reported 4.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.8%; NAICS 23813 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Greensboro, NC

All employers in Greensboro →