Skip to content
SafetyRecord logoSafetyRecord
KIMBER MANUFACTURING INC
$25,690
penalties
39
viol.
4
insp.

KIMBER MANUFACTURING INC

1 LAWTON STREET, YONKERS, NY 10705

Inspections
4
Sep 1996 to May 2005 · 2 safety, 2 health
Violations
39
across 4 inspections
Penalties on record
$25,690
latest amounts in DOL records
By classification
Serious 25Willful 0Repeat 3Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 6, 2005Referral (C) · Partial scope, Health#307665364$4,8308 viol.

Inspection #307665364

Dates

Opened
May 6, 2005
Closing Conference Date
Jul 14, 2005
Closed
Nov 18, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
138
Related Activity
1 referral

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$8,050
Penalties on Record
$4,830
Site Address
1 Lawton Street, Yonkers, NY 10705
Industry
332999 All Other Miscellaneous Fabricated Metal Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30 - 0.0060246mg/m³
Iron Oxide Fume30mg/m³
Lead, Inorganic (as Pb)30.0097657 - 0.0292722mg/m³
Manganese Fume (as Mn)30mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30mg/m³

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious530$4,900$2,940Aug 17, 2005--
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G01
Serious530$0$0Aug 31, 2005--
01001C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious530$0$0Aug 17, 2005--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Serious160$1,400$840Aug 17, 2005--
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 C02 II
Serious160$0$0Aug 31, 2005--
01003A1910.1025
Lead
OSHA citation code: 19101025 D02
Serious130$1,750$1,050Jul 20, 2005--
01003B1910.1025
Lead
OSHA citation code: 19101025 H01
Serious160$0$0Aug 17, 2005--
020011910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 F02 I
Other112$0$0Aug 31, 2005--
Apr 28, 2005Planned (H) · Complete scope, Safety#307665026$4,0006 viol.

Inspection #307665026

Dates

Opened
Apr 28, 2005
Closing Conference Date
Jun 29, 2005
Contested
Aug 8, 2005
Final Order
Oct 26, 2005
Closed
Dec 13, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
138

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$6,300
Penalties on Record
$4,000
Site Address
1 Lawton Street, Yonkers, NY 10705
Industry
332710 Machine Shops

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious22$3,500$2,222Dec 9, 2005Aug 8, 2005Oct 26, 2005
01001C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious22$0$0Dec 9, 2005Aug 8, 2005Oct 26, 2005
01002B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Other16$0$0Dec 9, 2005Aug 8, 2005Oct 26, 2005
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$1,400$889Jul 18, 2005Aug 8, 2005Oct 26, 2005
01004A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious16$1,400$889Dec 9, 2005Aug 8, 2005Oct 26, 2005
01004B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 I
Serious16$0$0Jul 18, 2005Aug 8, 2005Oct 26, 2005
Oct 4, 1999Complaint (B) · Partial scope, Health#302802228$10,3607 viol.

Inspection #302802228

Dates

Opened
Oct 4, 1999
Closing Conference Date
Oct 4, 1999
Closed
Jan 13, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
135
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 3 repeat, 1 other-than-serious
Initial Penalties
$14,800
Penalties on Record
$10,360
Site Address
1 Lawton Street, Yonkers, NY 10705
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$1,600$1,120Oct 26, 1999--
010021910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 I
Serious110$1,600$1,120Oct 26, 1999--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious22$1,200$840Oct 31, 1999--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat22$8,000$5,600Oct 26, 1999--
02002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Repeat14$2,400$1,680Dec 6, 1999--
02002B1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Repeat110$0$0Dec 6, 1999--
030011910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other11$0$0Dec 6, 1999--
Sep 25, 1996Planned (H) · Complete scope, Safety#110606050$6,50018 viol.

Inspection #110606050

Dates

Opened
Sep 25, 1996
Closing Conference Date
Sep 26, 1996
Closed
Dec 2, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
18
Violation Types
10 serious, 8 other-than-serious
Initial Penalties
$10,138
Penalties on Record
$6,500
Site Address
1 Lawton Street, Yonkers, NY 10705
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Serious311$750$464Oct 27, 1996--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious13$1,250$812Nov 29, 1996--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious13$1,250$812Nov 29, 1996--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious13$1,250$812Nov 29, 1996--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious199$2,500$1,600Nov 29, 1996--
01006A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious86$2,500$1,600Nov 29, 1996--
01006B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$0$0Nov 29, 1996--
01006C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious12$0$0Nov 29, 1996--
01006D1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious73$0$0Nov 29, 1996--
010071910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious42$638$400Sep 25, 1996--
020011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Other19$0$0Nov 29, 1996--
020021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F01
Other19$0$0Nov 29, 1996--

Showing the 12 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)5 citations · $4,658
1910.1200Hazard Communication5 citations · $2,520
1910.219Mechanical Power-Transmission Apparatus4 citations · $1,600

Chemical exposure sampling

Samples
39
Substances
13
Inspections
1

Other inspected employers in YONKERS, NY