KIVORT STEEL INC.
RTE 7, Warnerville, NY 12187
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 19, 1998#302001938Mar 19, 1998Planned (H) · Complete scope, Safety#302001938$1,75010 viol.10 violations$1,750 in penalties
Inspection #302001938
Dates
- Opened
- Mar 19, 1998
- Closing Conference Date
- Mar 19, 1998
- Closed
- Jul 24, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 13
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 7 serious, 3 other-than-serious
- Initial Penalties
- $3,600
- Penalties on Record
- $1,750
- Site Address
- Route 7, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D01 | Serious | 1 | 7 | $800 | $390 | May 3, 1998 | - | - |
| 01001B | 1910.136 Foot Protection OSHA citation code: 19100136 A | Serious | 1 | 7 | $0 | $0 | May 3, 1998 | - | - |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 7 | $1,000 | $485 | May 3, 1998 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 7 | $1,000 | $485 | Jun 3, 1998 | - | - |
| 01004A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B01 | Serious | 1 | 7 | $800 | $390 | May 3, 1998 | - | - |
| 01004B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 7 | $0 | $0 | May 3, 1998 | - | - |
| 01004C | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 7 | $0 | $0 | May 3, 1998 | - | - |
Showing the 7 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Oct 15, 1990#106895352Oct 15, 1990Referral (C) · Partial scope, Health#106895352$00 viol.0 violations$0 in penalties
Inspection #106895352
Dates
- Opened
- Oct 15, 1990
- Closing Conference Date
- Nov 23, 1990
- Closed
- Dec 5, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Route 7, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 2 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 3 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3 | 0 | mg/m³ |
| Copper Fume (as Cu) | 3 | 0 - 0.0478 | mg/m³ |
| Iron Oxide Fume | 3 | 0 - 6.3336 | mg/m³ |
| Lead, Inorganic (as Pb) | 3 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 3 | 0 - 0.0209 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 3 | 0 | mg/m³ |
| Zinc Oxide Fume | 3 | 0 - 9.7814 | mg/m³ |
Jun 7, 1990#107514036Jun 7, 1990Complaint (B) · Complete scope, Safety#107514036$13,38047 viol.47 violations$13,380 in penalties
Inspection #107514036
Dates
- Opened
- Jun 7, 1990
- Closing Conference Date
- Oct 4, 1990
- Closed
- Aug 13, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 47
- Violation Types
- 45 serious, 2 other-than-serious
- Initial Penalties
- $19,510
- Penalties on Record
- $13,380
- Site Address
- Route 7, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (7 of 47 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Serious | 2 | 12 | $200 | $260 | Dec 13, 1990 | - | - |
| 01002 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Serious | 3 | 12 | $810 | $510 | Dec 13, 1990 | - | - |
| 01003 | 1910.38 Emergency Action Plans OSHA citation code: 19100038 A01 | Serious | 1 | 17 | $260 | $260 | Dec 13, 1990 | - | - |
| 01004 | 1910.106 Flammable Liquids OSHA citation code: 19100106 B02 IVA | Serious | 3 | 12 | $300 | $200 | Dec 13, 1990 | - | - |
| 01005 | 1910.106 Flammable Liquids OSHA citation code: 19100106 B02 VA | Serious | 12 | 12 | $300 | $200 | Dec 13, 1990 | - | - |
| 01006 | 1910.106 Flammable Liquids OSHA citation code: 19100106 B02 VIIA | Serious | 3 | 12 | $300 | $200 | Dec 13, 1990 | - | - |
| 01007 | 1910.106 Flammable Liquids OSHA citation code: 19100106 B06 | Serious | 3 | 12 | $300 | $200 | Dec 13, 1990 | - | - |
Showing the 7 violations listed first by citation identifier. This inspection has 47 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 24, 1987#100216084Apr 24, 1987Complaint (B) · Partial scope, Safety#100216084$01 viol.1 violation$0 in penalties
Inspection #100216084
Dates
- Opened
- Apr 24, 1987
- Closing Conference Date
- Apr 24, 1987
- Closed
- Jun 2, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Route 7, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Other | 2 | 6 | $0 | $0 | May 18, 1987 | - | - |
Dec 2, 1985#100216852Dec 2, 1985Planned (H) · Complete scope, Safety#100216852$02 viol.2 violations$0 in penalties
Inspection #100216852
Dates
- Opened
- Dec 2, 1985
- Closing Conference Date
- Dec 2, 1985
- Closed
- Jan 3, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- P. O. Box Drawer D, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Other | 3 | 8 | $0 | $0 | Jan 28, 1986 | - | - |
| 01002 | 1910.181 Derricks OSHA citation code: 19100181 I04 I | Other | 1 | 1 | $0 | $0 | Jan 28, 1986 | - | - |
Sep 7, 1983#10773885Sep 7, 1983Planned (H) · Partial scope, Safety#10773885$06 viol.6 violations$0 in penalties
Inspection #10773885
Dates
- Opened
- Sep 7, 1983
- Closing Conference Date
- Sep 7, 1983
- Closed
- Oct 27, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 11
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Rte 7, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.110 Storage and Handling of Liquefied Petroleum Gases OSHA citation code: 19100110 C05 | Other | 1 | - | $0 | $0 | Sep 22, 1983 | - | - |
| 01002 | 1910.180 Crawler Locomotive and Truck Cranes OSHA citation code: 19100180 C02 | Other | 2 | - | $0 | $0 | Oct 14, 1983 | - | - |
| 01003 | 1910.180 Crawler Locomotive and Truck Cranes OSHA citation code: 19100180 D06 | Other | 2 | - | $0 | $0 | Sep 22, 1983 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 1 | - | $0 | $0 | Sep 22, 1983 | - | - |
| 01005 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 I02 | Other | 1 | - | $0 | $0 | Sep 22, 1983 | - | - |
| 01006 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 A02 IVC | Other | 1 | - | $0 | $0 | Sep 22, 1983 | - | - |
Mar 3, 1983#10703361Mar 3, 1983Planned (H) · Records Only scope, Safety#10703361$00 viol.0 violations$0 in penalties
Inspection #10703361
Dates
- Opened
- Mar 3, 1983
- Closing Conference Date
- Mar 3, 1983
- Closed
- Mar 22, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 15
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Rte 7 Main St, Warnerville, NY 12187
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
7 inspections, 1983 to 1998. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.