Skip to content
SafetyRecord logoSafetyRecord
L & L PAINTING CO, INC.
$3,000
penalties
3
viol.
4
insp.

L & L PAINTING CO, INC.

GEORGE WASHINGTON BRIDGE NORTH LEG, Fort Lee, NJ 07024NAICS 237310 Highway, Street, and Bridge Construction

Inspections
4
Aug 2002 to Jul 2004 · 2 safety, 2 health
Violations
3
across 4 inspections
Penalties on record
$3,000
latest amounts in DOL records
By classification
Serious 1Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 6, 2004Referral (C) · Partial scope, Health#306559469$1,0001 viol.

Inspection #306559469

Dates

Opened
Jul 6, 2004
Closing Conference Date
Jul 6, 2004
Contested
Dec 15, 2004
Final Order
Feb 13, 2009
Closed
Apr 21, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
350
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,625
Penalties on Record
$1,000
Site Address
George Washington Bridge North Leg, Fort Lee, NJ 07024
Industry
237310 Highway, Street, and Bridge Construction

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)54P / 1A0mg/m³
Beryllium and Beryllium Compounds (as Be)54P / 1A0 - 0.002517mg/m³
Cadmium54P / 1A0mg/m³
Chromium, Metal and Insoluble Salts54P / 1A0 - 0.0817627mg/m³
Cobalt, Metal, Dust and Fume (as Co)54P / 1A0 - 0.0211329mg/m³
Copper Fume (as Cu)54P / 1A0 - 0.0458399mg/m³
Iron Oxide Fume54P / 1A1.6452521 - 86.31429mg/m³
Lead, Inorganic (as Pb)1312P / 1A0.036 - 9.4mg/m³
Manganese Fume (as Mn)54P / 1A0.0050655 - 0.2367706mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)54P / 1A0mg/m³
Nickel, Metal and Insoluble compounds (as Ni)54P / 1A0 - 0.0678487mg/m³
Vanadium fume (as V2O5)54P / 1A0 - 0.1209437mg/m³
Zinc Oxide Fume54P / 1A0.0428286 - 0.9840278mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.62
Lead
OSHA citation code: 19260062 K02 I
Serious11$1,625$1,000Dec 12, 2004Dec 15, 2004Feb 13, 2009
Aug 27, 2003Complaint (B) · Partial scope, Safety#306554551$00 viol.

Inspection #306554551

Dates

Opened
Aug 27, 2003
Closing Conference Date
Oct 28, 2003
Closed
Oct 31, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
George Washington Bridge North Leg, Fort Lee, NJ 07024
Industry
238320 Painting and Wall Covering Contractors

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Sep 3, 2002Planned (H) · Partial scope, Health#305070831$00 viol.

Inspection #305070831

Dates

Opened
Sep 3, 2002
Closing Conference Date
Sep 3, 2002
Closed
Nov 6, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
George Washington Bridge North Leg, Fort Lee, NJ 07024
Industry
237310 Highway, Street, and Bridge Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 27, 2002Planned (H) · Partial scope, Safety#305070690$2,0002 viol.

Inspection #305070690

Dates

Opened
Aug 27, 2002
Closing Conference Date
Dec 17, 2002
Contested
Jan 10, 2003
Final Order
May 12, 2003
Closed
May 16, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
7

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$4,500
Penalties on Record
$2,000
Site Address
George Washington Bridge North Leg, Fort Lee, NJ 07024
Industry
237310 Highway, Street, and Bridge Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A06
Other11$2,000$1,500Dec 27, 2002Jan 10, 2003May 12, 2003
010021926.454
OSHA citation code: 19260454 A
Other11$2,500$500Mar 8, 2003Jan 10, 2003May 12, 2003
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.62Lead1 citation · $1,000
1926.451Scaffolding - General Requirements1 citation · $1,500
1926.4541 citation · $500

Chemical exposure sampling

Samples
73
Substances
13
Inspections
1

Industry comparison

Violations per inspection
This employer0.8
Industry average1.6
Penalties per inspection
This employer$750
Industry average$2,263

Heavy and Civil Engineering Construction, 69,176 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Fort Lee, NJ