Skip to content
SafetyRecord logoSafetyRecord
L M INDUSTRIES INC - GREER PLANT
$2,060
penalties
30
viol.
4
insp.

L M INDUSTRIES INC - GREER PLANT

1881 SUBER MILL RD, GREER, SC 29651

Inspections
4
Aug 1989 to Feb 1992 · 2 safety, 2 health
Violations
30
across 4 inspections
Penalties on record
$2,060
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 21

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 28, 1992Planned (H) · Complete scope, Safety#115678104$50010 viol.

Inspection #115678104

Dates

Opened
Feb 28, 1992
Closing Conference Date
Feb 28, 1992
Closed
May 15, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
10
Violation Types
2 serious, 8 other-than-serious
Initial Penalties
$1,250
Penalties on Record
$500
Site Address
1881 Suber Mill Rd, Greer, SC 29651
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious19$375$150Apr 16, 1992--
010021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02 1
Serious1-$875$350Apr 22, 1992--
020011910.20
OSHA citation code: 19100020 G02
Other111$0$0Apr 16, 1992--
020021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Other11$0$0May 15, 1992--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other39$0$0Apr 16, 1992--
020041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other311$0$0Apr 16, 1992--
020051910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other55$0$0Apr 22, 1992--
020061910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Other15$0$0Apr 30, 1992--
020071910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Other11$0$0Apr 22, 1992--
020081910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other11$0$0Apr 16, 1992--
Oct 17, 1990Follow-Up (F) · Partial scope, Health#111016887$00 viol.

Inspection #111016887

Dates

Opened
Oct 17, 1990
Closing Conference Date
Oct 18, 1990
Closed
Jan 25, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1881 Suber Mill Rd, Greer, SC 29651
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 21, 1990Planned (H) · Complete scope, Health#107833410$84012 viol.

Inspection #107833410

Dates

Opened
Jun 21, 1990
Closing Conference Date
Aug 13, 1990
Closed
Jan 25, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22

Violations and Penalties

Total Violations
12
Violation Types
5 serious, 7 other-than-serious
Initial Penalties
$1,680
Penalties on Record
$840
Site Address
1881 Suber Mill Rd, Greer, SC 29651
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
0300110012
OSHA citation code: 10012 A
Serious11$480$240Sep 4, 1990--
030021910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious22$360$180Oct 1, 1990--
030031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M05 III
Serious11$480$240Sep 4, 1990--
03004A1910.1000
Air Contaminants
OSHA citation code: 19101000 A03
Serious11$360$180Oct 1, 1990--
03004B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Oct 1, 1990--
0400130002
OSHA citation code: 30002 B
Other122$0$0Sep 10, 1990--
040021910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 H06 IIB
Other15$0$0Oct 1, 1990--
040031910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Other11$0$0Sep 10, 1990--
040051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other22$0$0Sep 1, 1990--
040061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other22$0$0Sep 1, 1990--
040071910.1200
Hazard Communication
OSHA citation code: 19101200 F05
Other13$0$0Sep 10, 1990--
040081910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other122$0$0Oct 1, 1990--

Failure to Abate Penalties2 citations, $950 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
04002#111016887Dec 17, 1990$900--
04008#111016887Dec 17, 1990$50--
Aug 16, 1989Planned (H) · Complete scope, Safety#107832370$7208 viol.

Inspection #107832370

Dates

Opened
Aug 16, 1989
Closing Conference Date
Aug 16, 1989
Closed
Oct 2, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 6 other-than-serious
Initial Penalties
$720
Penalties on Record
$720
Site Address
1881 Suber Mill Rd, Greer, SC 29651
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious24$360$360Sep 10, 1989--
010021910.304
Wiring design and protection
OSHA citation code: 19100304 F05 VC
Serious13$360$360Sep 12, 1989--
0200150002
OSHA citation code: 50002 A
Other118$0$0Sep 10, 1989--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G03
Other12$0$0Sep 10, 1989--
020031910.252
General requirements
OSHA citation code: 19100252 A02 IID
Other29$0$0Sep 10, 1989--
020041910.252
General requirements
OSHA citation code: 19100252 A02 IVC
Other210$0$0Sep 21, 1989--
020051910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other11$0$0Sep 12, 1989--
020061910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 III
Other118$0$0Sep 21, 1989--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Wiring methods, components, and equipment for general use4 citations · $350
1910.304Wiring design and protection3 citations · $870
1910.1000Air Contaminants2 citations · $180

Other inspected employers in GREER, SC

All employers in GREER →