Skip to content
SafetyRecord logoSafetyRecord
LEROY RUFFIN DBA RUFFIN CONSTRUCTION CO.
$500
penalties
19
viol.
1
insp.

LEROY RUFFIN DBA RUFFIN CONSTRUCTION CO.

2308 N. WILLIAM ST, GOLDSBORO, NC 27530NAICS 238140 Masonry Contractors

Inspections
1
Jul 2003 to Jul 2003 · 1 safety, 0 health
Violations
19
across 1 inspection
Penalties on record
$500
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 10, 2003Referral (C) · Partial scope, Safety#306590951$50019 viol.

Inspection #306590951

Dates

Opened
Jul 10, 2003
Closing Conference Date
Jul 10, 2003
Closed
Feb 18, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 referral

Violations and Penalties

Total Violations
19
Violation Types
16 serious, 3 other-than-serious
Initial Penalties
$1,450
Penalties on Record
$500
Site Address
2308 N. William St, Goldsboro, NC 27530
Industry
238140 Masonry Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (19 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head protection
OSHA citation code: 19260100 A
Serious12$500$0Sep 25, 2003--
010021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious11$250$0Oct 17, 2003--
01003A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B01 I
Serious15$700$500Sep 25, 2003--
01003B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B04
Serious15$0$0Sep 25, 2003--
01003C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B05 I
Serious15$0$0Sep 25, 2003--
01003D1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B07
Serious15$0$0Sep 25, 2003--
01003E1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C01
Serious15$0$0Sep 25, 2003--
01003F1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Serious15$0$0Sep 25, 2003--
01003G1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious15$0$0Sep 25, 2003--
01003H1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious15$0$0Sep 25, 2003--
01003I1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious15$0$0Sep 25, 2003--
01003J1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 H02 I
Serious11$0$0Sep 25, 2003--
01003K1926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C02
Serious15$0$0Sep 25, 2003--
01003L1926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C04
Serious15$0$0Sep 25, 2003--
01003M1926.454
OSHA citation code: 19260454 A
Serious15$0$0Sep 25, 2003--
01003N1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious15$0$0Oct 17, 2003--
02001A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other15$0$0Oct 17, 2003--
02001B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other15$0$0Sep 25, 2003--
02001C1926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B02
Other15$0$0Sep 25, 2003--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements10 citations · $500
1926.452Additional Requirements for Specific Scaffold Types2 citations · $0
1926.20General Safety and Health Provisions2 citations · $0

Industry comparison

Violations per inspection
This employer19.0
Industry average2.1
Penalties per inspection
This employer$500
Industry average$2,531

Specialty Trade Contractors, 551,927 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: masonry contractors reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 15.2%; NAICS 23814 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GOLDSBORO, NC