Skip to content
SafetyRecord logoSafetyRecord
LYONS CONSTRUCTION SERVICES
$9,470
penalties
11
viol.
3
insp.

LYONS CONSTRUCTION SERVICES

STEELTON-HIGHSPIRE ELEMENTARY SCHOOL, Steelton, PA 17113NAICS 236220 Commercial and Institutional Building Construction

Inspections
3
Jan 2007 to May 2007 · 3 safety, 0 health
Violations
11
across 3 inspections
Penalties on record
$9,470
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 1Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 9, 2007Follow-Up (F) · Partial scope, Safety#310837067$8401 viol.

Inspection #310837067

Dates

Opened
May 9, 2007
Closing Conference Date
May 9, 2007
Closed
Jun 29, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,200
Penalties on Record
$840
Site Address
Steelton-Highspire Elementary School, Steelton, PA 17113
Industry
236220 Commercial and Institutional Building Construction

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 D06 I
Serious11$1,200$840Jun 11, 2007--
Apr 17, 2007Complaint (B) · Partial scope, Safety#310837497$00 viol.

Inspection #310837497

Dates

Opened
Apr 17, 2007
Closing Conference Date
Apr 17, 2007
Closed
Apr 17, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
7
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Highspire Elementary School, Steelton, PA 17113
Industry
236220 Commercial and Institutional Building Construction

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jan 18, 2007Planned (H) · Complete scope, Safety#308480409$8,63010 viol.

Inspection #308480409

Dates

Opened
Jan 18, 2007
Closing Conference Date
Jan 18, 2007
Closed
Jul 12, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
10
Violation Types
8 serious, 1 repeat, 1 other-than-serious
Initial Penalties
$12,600
Penalties on Record
$8,630
Site Address
Steelton-Highspire Elementary School, Steelton, PA 17113
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 B02
Serious14$1,125$790Feb 28, 2007--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C01
Serious14$1,125$790Feb 28, 2007--
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F03
Serious110$1,125$790Feb 28, 2007--
010041926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious24$1,125$790Feb 28, 2007--
010051926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W01
Serious14$1,125$790Feb 28, 2007--
010061926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 W06 II
Serious14$1,125$790Feb 28, 2007--
010071926.454
OSHA citation code: 19260454 A01
Serious17$1,125$790Feb 28, 2007--
010081926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious13$1,125$400Feb 28, 2007--
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Repeat23$3,000$2,100Feb 28, 2007--
030011903.19
Abatement Verification
OSHA citation code: 19030019 C01
Other13$600$600May 7, 2007--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements4 citations · $3,160
1926.452Additional Requirements for Specific Scaffold Types2 citations · $1,580
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $2,500

Industry comparison

Violations per inspection
This employer3.7
Industry average1.5
Penalties per inspection
This employer$3,157
Industry average$1,287

Construction of Buildings, 202,767 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: nonresidential building construction reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 6.8%; NAICS 2362 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Steelton, PA