Skip to content
SafetyRecord logoSafetyRecord
M&M CONTRACTING, INC.
$8,800
penalties
24
viol.
2
insp.

M&M CONTRACTING, INC.

3001 FARM WALK RD., YORKTOWN HEIGHTS, NY 10598NAICS 238160 Roofing Contractors

Inspections
2
Feb 2013 to Feb 2013 · 2 safety, 0 health
Violations
24
across 2 inspections
Penalties on record
$8,800
latest amounts in DOL records
By classification
Serious 21Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 1, 2013Planned (H) · Complete scope, Safety#338684038$4,60013 viol.

Inspection #338684038

Dates

Opened
Feb 1, 2013
Closing Conference Date
Feb 1, 2013
Final Order
Apr 29, 2013
Closed
Mar 3, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6
Related Activity
1 complaint

Violations and Penalties

Total Violations
13
Violation Types
12 serious, 1 other-than-serious
Initial Penalties
$9,200
Penalties on Record
$4,600
Site Address
3001 Farm Walk Rd., Yorktown Heights, NY 10598
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E01
Serious22$1,200$600May 15, 2013-Apr 29, 2013
01002A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 I
Serious12$2,800$1,400May 15, 2013-Apr 29, 2013
01002B1926.454
Scaffolding - Training
OSHA citation code: 19260454 A
Serious22$0$0May 15, 2013-Apr 29, 2013
01002C1926.454
Scaffolding - Training
OSHA citation code: 19260454 B
Serious22$0$0May 15, 2013-Apr 29, 2013
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious16$2,800$1,400May 15, 2013-Apr 29, 2013
01004A1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious66$0$0May 15, 2013-Apr 29, 2013
01004B1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious66$0$0May 15, 2013-Apr 29, 2013
01005A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious16$1,200$600May 15, 2013-Apr 29, 2013
01005B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Serious16$0$0May 15, 2013-Apr 29, 2013
01005C1926.1060
Stairways and Ladders - Training (Construction)
OSHA citation code: 19261060 A
Serious66$0$0May 15, 2013-Apr 29, 2013
01006A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B21
Serious16$1,200$600May 15, 2013-Apr 29, 2013
01006B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B22
Serious16$0$0May 15, 2013-Apr 29, 2013
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other11$0$0May 15, 2013-Apr 29, 2013
Feb 1, 2013Planned (H) · Complete scope, Safety#338681034$4,20011 viol.

Inspection #338681034

Dates

Opened
Feb 1, 2013
Closing Conference Date
Feb 1, 2013
Final Order
Apr 29, 2013
Closed
Mar 3, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
9 serious, 2 other-than-serious
Initial Penalties
$8,400
Penalties on Record
$4,200
Site Address
1509 Indiana Rd., Yorktown Heights, NY 10598
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.21
Safety Training and Education
OSHA citation code: 19260021 B02
Serious55$2,000$1,000May 15, 2013-Apr 29, 2013
01001B1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious11$0$0May 15, 2013-Apr 29, 2013
01002A1926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B13
Serious15$2,800$1,400May 15, 2013-Apr 29, 2013
01002B1926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious55$0$0May 15, 2013-Apr 29, 2013
01003A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious15$1,200$600-Apr 29, 2013
01003B1926.1060
Stairways and Ladders - Training (Construction)
OSHA citation code: 19261060 A
Serious55$0$0May 15, 2013-Apr 29, 2013
010041926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Serious15$1,200$600May 15, 2013-Apr 29, 2013
01005A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B21
Serious15$1,200$600May 15, 2013-Apr 29, 2013
01005B1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B22
Serious15$0$0May 15, 2013-Apr 29, 2013
020011926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 G
Other11$0$0May 15, 2013-Apr 29, 2013
020021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other11$0$0May 15, 2013-Apr 29, 2013
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.1053Ladders (Construction)8 citations · $3,000
1926.404Electrical - Wiring Design and Protection (Construction)3 citations · $0
1926.454Scaffolding - Training2 citations · $0

Industry comparison

Violations per inspection
This employer12.0
Industry average2.1
Penalties per inspection
This employer$4,400
Industry average$2,537

Specialty Trade Contractors, 558,619 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: roofing contractors reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.7%; NAICS 23816 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in YORKTOWN HEIGHTS, NY