Skip to content
SafetyRecord logoSafetyRecord
MANTH-BROWNELL INC
$14,685
penalties
39
viol.
6
insp.

MANTH-BROWNELL INC

1120 FYLER RD, KIRKVILLE, NY 13082

Inspections
6
Sep 1982 to Apr 2003 · 3 safety, 3 health
Violations
39
across 6 inspections
Penalties on record
$14,685
latest amounts in DOL records
By classification
Serious 27Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 22, 2003Planned (H) · Complete scope, Safety#306308420$1,9805 viol.

Inspection #306308420

Dates

Opened
Apr 22, 2003
Closing Conference Date
Apr 23, 2003
Closed
May 14, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
167

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$3,300
Penalties on Record
$1,980
Site Address
1120 Fyler Rd, Kirkville, NY 13082
Industry
332721 Precision Turned Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 C
Serious12$1,375$825Jun 3, 2003--
01002A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious23$1,100$660May 6, 2003--
01002B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious21$0$0May 14, 2003--
010031910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 IIIF
Serious12$825$495May 6, 2003--
020011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Other12$0$0Jun 3, 2003--
Apr 22, 2003Planned (H) · Complete scope, Health#306308404$3,9609 viol.

Inspection #306308404

Dates

Opened
Apr 22, 2003
Closing Conference Date
Apr 23, 2003
Closed
May 14, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
167

Violations and Penalties

Total Violations
9
Violation Types
9 serious
Initial Penalties
$6,600
Penalties on Record
$3,960
Site Address
1120 Fyler Rd, Kirkville, NY 13082
Industry
332721 Precision Turned Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
OSHA citation code: 19100106 E06 II
Serious11$825$495May 14, 2003--
01002A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious11$1,375$825Jun 3, 2003--
01002B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Serious11$0$0Jun 3, 2003--
01002C1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G01
Serious11$0$0Jun 3, 2003--
010031910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$825$495May 14, 2003--
010041910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D07
Serious11$825$495May 6, 2003--
010051910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious34$1,375$825May 14, 2003--
01006A1910.1025
Lead
OSHA citation code: 19101025 D02
Serious11$1,375$825Jun 30, 2003--

Showing the 8 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 6, 1998Planned (H) · Complete scope, Safety#300631389$6,48016 viol.

Inspection #300631389

Dates

Opened
Oct 6, 1998
Closing Conference Date
Oct 13, 1998
Closed
Jan 8, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
214

Violations and Penalties

Total Violations
16
Violation Types
11 serious, 5 other-than-serious
Initial Penalties
$7,878
Penalties on Record
$6,480
Site Address
1120 Fyler Rd, Kirkville, NY 13082
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious55$1,100$770Dec 22, 1998--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06 I
Serious1100$1,375$963Dec 22, 1998--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious24$1,375$963Nov 24, 1998--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious21$701$491Nov 23, 1998--
010061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious28$825$578Dec 22, 1998--
01008A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious36$1,100$770Nov 24, 1998--
01008B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious24$0$0Dec 22, 1998--
010091910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious34$701$491Nov 23, 1998--

Showing the 8 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 6, 1998Planned (H) · Complete scope, Health#107697245$7703 viol.

Inspection #107697245

Dates

Opened
Oct 6, 1998
Closing Conference Date
Oct 7, 1998
Closed
Jan 8, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
214

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$1,100
Penalties on Record
$770
Site Address
1120 Fyler Rd, Kirkville, NY 13082
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious2100$1,100$770Nov 24, 1998--
020011904.2
OSHA citation code: 19040002 A
Other1616$0$0Nov 24, 1998--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other228$0$0Nov 24, 1998--
May 2, 1997Referral (C) · Partial scope, Health#101545473$1,3754 viol.

Inspection #101545473

Dates

Opened
May 2, 1997
Closing Conference Date
May 2, 1997
Closed
Jul 10, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
206
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$1,375
Penalties on Record
$1,375
Site Address
1120 Fyler Rd, Kirkville, NY 13082
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC80.3265 - 0.8406mg/m³
Oil Mist, Mineral80.3265 - 0.8406mg/m³
Sample WeightQC90 - 0.807mg
Stoddard Solvent246.7778 - 64.4375mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 II
Serious130$1,375$1,375Jul 14, 1997--
02001A1910.132
General requirements
OSHA citation code: 19100132 D02
Other1100$0$0Jun 27, 1997--
02001B1910.132
General requirements
OSHA citation code: 19100132 F04
Other1100$0$0Jun 24, 1997--
020021910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 I
Other112$0$0Jul 14, 1997--
Sep 3, 1982Planned (H) · Complete scope, Safety#12046520$1202 viol.

Inspection #12046520

Dates

Opened
Sep 3, 1982
Closing Conference Date
Sep 3, 1982
Closed
Nov 1, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
48

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
1120 Fyler Rd, Kirkville, NY 13082
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious3-$120$120Oct 11, 1982--
020011910.23
OSHA citation code: 19100023 C01
Other3-$0$0Oct 11, 1982--
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)5 citations · $3,077
1910.305Wiring methods, components, and equipment for general use4 citations · $986
1910.219Mechanical Power-Transmission Apparatus4 citations · $890

Chemical exposure sampling

Samples
27
Substances
4
Inspections
1

Industry comparison

BLS 2024 survey: precision turned product manufacturing reported 3.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.5%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in KIRKVILLE, NY

All employers in KIRKVILLE →