Skip to content
SafetyRecord logoSafetyRecord
MAYO CO INC
$9,920
penalties
22
viol.
4
insp.

MAYO CO INC

5010 FLINT HILL ROAD, Austell, GA 30001

Inspections
4
Jul 1981 to Sep 1998 · 3 safety, 1 health
Violations
22
across 4 inspections
Penalties on record
$9,920
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 1, 1998Referral (C) · Partial scope, Health#300180528$8002 viol.

Inspection #300180528

Dates

Opened
Sep 1, 1998
Closing Conference Date
Sep 15, 1998
Closed
Feb 4, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
38
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,250
Penalties on Record
$800
Site Address
5010 Flint Hill Road, Austell, GA 30001
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Beryllium and Beryllium Compounds (as Be)90mg/m³
Chromium, Metal and Insoluble Salts90 - 0.0049mg/m³
Cobalt, Metal, Dust and Fume (as Co)90 - 0.000889mg/m³
Copper Fume (as Cu)90.0028 - 0.0127mg/m³
Iron Oxide Fume90.8247 - 3.5312mg/m³
Lead, Inorganic (as Pb)90 - 0.0107mg/m³
Manganese Fume (as Mn)90.0709 - 0.245mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90 - 0.0013mg/m³
Vanadium fume (as V2O5)90mg/m³
Zinc Oxide Fume90.0033 - 0.0392mg/m³

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious238$1,250$800Jan 20, 1999--
01001B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious238$0$0Jan 20, 1999--
Aug 27, 1998Complaint (B) · Complete scope, Safety#300180452$9,00017 viol.

Inspection #300180452

Dates

Opened
Aug 27, 1998
Closing Conference Date
Sep 15, 1998
Closed
Jul 16, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
38
Related Activity
1 complaint

Violations and Penalties

Total Violations
17
Violation Types
16 serious, 1 other-than-serious
Initial Penalties
$18,400
Penalties on Record
$9,000
Site Address
5010 Flint Hill Road, Austell, GA 30001
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

AmputationHospitalizationAug 26, 1998

Employee's fingers amputated by hydraulic shear

Injury: AmputationBody part: Finger(s)Source: MachineEvent: Caught In or Between

Violations

Violation list (12 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.26
Dockboards
OSHA citation code: 19100026 A03 VII
Serious11$750$300Jan 21, 1999--
01001B1910.26
Dockboards
OSHA citation code: 19100026 A03 VIII
Serious11$0$0Jan 21, 1999--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Serious526$525$200Jan 19, 1999--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious49$7,000$5,425Jul 16, 1999--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious24$525$275Jan 21, 1999--
01005A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious13$875$400Jan 19, 1999--
01005B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious13$0$0Jan 19, 1999--
01006A1910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B03
Serious110$2,500$1,000Jan 19, 1999--
01006B1910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 IA
Serious13$0$0Jan 21, 1999--
01006C1910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious124$0$0Jan 19, 1999--
01006D1910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious12$0$0Jan 19, 1999--
01006E1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Serious126$0$0Feb 15, 1999--

Showing the 12 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 3, 1983Planned (H) · Records Only scope, Safety#13115092$00 viol.

Inspection #13115092

Dates

Opened
Aug 3, 1983
Closing Conference Date
Aug 3, 1983
Closed
Aug 9, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5010 Flint Hill Rd, Austell, GA 30001
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 28, 1981Complaint (B) · Complete scope, Safety#13126719$1203 viol.

Inspection #13126719

Dates

Opened
Jul 28, 1981
Closing Conference Date
Jul 28, 1981
Closed
Feb 22, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
24
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
5010 Flint Hill Road, Austell, GA 30001
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious2-$120$120Feb 22, 1982--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D01
Other1-$0$0Sep 4, 1981--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other1-$0$0Sep 4, 1981--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.157Portable Fire Extinguishers3 citations · $200
1910.212General Requirements for All Machines (Machine Guarding)3 citations · $5,820
1910.252Welding, Cutting, and Brazing - General Requirements3 citations · $1,000

Chemical exposure sampling

Samples
108
Substances
12
Inspections
1

Other inspected employers in Austell, GA