Skip to content
SafetyRecord logoSafetyRecord
MEADOR PRODUCTS, INC. DBA TAYLOR FOUNDRY
$240
penalties
12
viol.
3
insp.

MEADOR PRODUCTS, INC. DBA TAYLOR FOUNDRY

100 HENRY S GRACE FWY, Wichita Falls, TX 76305

Inspections
3
Jul 1990 to Mar 1994 · 1 safety, 2 health
Violations
12
across 3 inspections
Penalties on record
$240
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 23, 1994Planned (H) · No Inspection scope, Health#108921107$00 viol.

Inspection #108921107

Dates

Opened
Mar 23, 1994
Closing Conference Date
Not recorded
Closed
Mar 23, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
100 Henry S Grace Fwy, Wichita Falls, TX 76305
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 1, 1992Planned (H) · No Inspection scope, Safety#110364007$00 viol.

Inspection #110364007

Dates

Opened
Apr 1, 1992
Closing Conference Date
Apr 1, 1992
Closed
Apr 3, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
100 Henry S Grace Fwy, Wichita Falls, TX 76305
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 24, 1990Planned (H) · Complete scope, Health#106605306$24012 viol.

Inspection #106605306

Dates

Opened
Jul 24, 1990
Closing Conference Date
Jul 25, 1990
Closed
Jun 7, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
12
Violation Types
4 serious, 8 other-than-serious
Initial Penalties
$600
Penalties on Record
$240
Site Address
100 Henry S Grace Fwy, Wichita Falls, TX 76305
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium Fume (as Cd)30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30mg/m³
Iron Oxide Fume30 - 0.1182mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30 - 0.0055mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30 - 0.0015mg/m³

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
OSHA citation code: 19100106 E02 IVA
Serious12$200$120Oct 6, 1990--
01001B1910.106
OSHA citation code: 19100106 E06 II
Serious16$0$0Oct 6, 1990--
01002A1910.108
OSHA citation code: 19100108 E05
Serious15$200$120Oct 10, 1990--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious15$0$0Oct 10, 1990--
010031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Other12$200$0Nov 16, 1990--
020011910.22
OSHA citation code: 19100022 A01
Other12$0$0Nov 19, 1990--
020021910.22
OSHA citation code: 19100022 A02
Other130$0$0Dec 4, 1990--
020031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other132$0$0Nov 19, 1990--
020041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other15$0$0Nov 2, 1990--
020051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G03
Other15$0$0Nov 19, 1990--
020061910.165
Employee Alarm Systems
OSHA citation code: 19100165 D01
Other132$0$0Nov 19, 1990--
020071910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other11$0$0Nov 2, 1990--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $0
1910.1062 citations · $120
1910.222 citations · $0

Chemical exposure sampling

Samples
38
Substances
13
Inspections
1

Other inspected employers in Wichita Falls, TX