Skip to content
SafetyRecord logoSafetyRecord
MEISTER LOG & LUMBER CO
$5,800
penalties
28
viol.
7
insp.

MEISTER LOG & LUMBER CO

HWY 33, Reedsburg, WI 53959

Inspections
7
Aug 1972 to Jan 2002 · 6 safety, 1 health
Violations
28
across 7 inspections
Penalties on record
$5,800
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 25, 2002Planned (H) · Complete scope, Safety#303866156$3,3759 viol.

Inspection #303866156

Dates

Opened
Jan 25, 2002
Closing Conference Date
Feb 14, 2002
Closed
May 31, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 3 other-than-serious
Initial Penalties
$6,750
Penalties on Record
$3,375
Site Address
1440 Laukant Street, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 A01
Serious11$2,500$1,250Mar 26, 2002--
01002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious11$2,500$1,250May 28, 2002--
01002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious11$0$0Mar 26, 2002--
01003A1910.134
Respiratory Protection
OSHA citation code: 19100134 D01 III
Serious11$1,750$875Apr 23, 2002--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Serious11$0$0May 28, 2002--
01003C1910.1200
Hazard Communication
OSHA citation code: 19101200 H03 III
Serious11$0$0Apr 23, 2002--
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G05 IV
Other44$0$0Apr 8, 2002--

Showing the 7 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 25, 2002Planned (H) · Complete scope, Health#303865885$2,12510 viol.

Inspection #303865885

Dates

Opened
Jan 25, 2002
Closing Conference Date
Feb 14, 2002
Closed
Apr 30, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
10
Violation Types
6 serious, 4 other-than-serious
Initial Penalties
$4,250
Penalties on Record
$2,125
Site Address
1440 Laukant Street, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling10 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium10mg/m³
Copper Fume (as Cu)10.0085424mg/m³
Gravimetric DeterminationQC31P / 2A0.4359 - 6.2436mg/m³
Lead, Inorganic (as Pb)10mg/m³
Particulates not otherwise regulated (Respirable Fraction)10.4359mg/m³
Particulates not otherwise regulated (Total Dust)21P / 1A2.4249 - 6.2436mg/m³
Sample WeightQC31P / 2A0.1525 - 5.785mg
Silver, Metal and Soluble Compounds (as Ag)10mg/m³
Tin, inorganic compounds (except oxides) (as Sn)10.0161856mg/m³
Zinc Oxide Fume10.061348mg/m³

Violations

Violation list (7 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 A09
Serious11$750$375Mar 26, 2002--
010021910.23
OSHA citation code: 19100023 E01
Serious12$750$375Mar 26, 2002--
010031910.37
OSHA citation code: 19100037 Q01
Serious13$1,000$500Mar 26, 2002--
01004A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 A09
Serious11$1,000$500Mar 26, 2002--
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious11$0$0Mar 26, 2002--
010051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$750$375Mar 26, 2002--
020011910.37
OSHA citation code: 19100037 K02
Other12$0$0Mar 26, 2002--

Showing the 7 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 5, 1991Planned (H) · Complete scope, Safety#102507100$2504 viol.

Inspection #102507100

Dates

Opened
Dec 5, 1991
Closing Conference Date
Dec 5, 1991
Closed
Dec 30, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$250
Penalties on Record
$250
Site Address
1440 Laukant Street, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
OSHA citation code: 19040002 A
Other11$250$250Jan 13, 1992--
010021910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other11$0$0Dec 12, 1991--
010031910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Other11$0$0Dec 12, 1991--
010041910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other21$0$0Dec 12, 1991--
Feb 12, 1987Planned (H) · Records Only scope, Safety#101112522$00 viol.

Inspection #101112522

Dates

Opened
Feb 12, 1987
Closing Conference Date
Feb 12, 1987
Closed
Feb 13, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Co Hwy H - Viking Drive, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 26, 1984Planned (H) · Records Only scope, Safety#1324623$00 viol.

Inspection #1324623

Dates

Opened
Jun 26, 1984
Closing Conference Date
Jun 26, 1984
Closed
Jun 26, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hwy 33, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Oct 18, 1983Planned (H) · Records Only scope, Safety#15462815$00 viol.

Inspection #15462815

Dates

Opened
Oct 18, 1983
Closing Conference Date
Oct 18, 1983
Closed
Oct 18, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hy 33, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 10, 1972Planned (H) · Complete scope, Safety#15583420$505 viol.

Inspection #15583420

Dates

Opened
Aug 10, 1972
Closing Conference Date
Aug 10, 1972
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
14

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$50
Penalties on Record
$50
Site Address
Po Box 308, Reedsburg, WI 53959
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 A
Other1-$0$0Oct 25, 1972--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D03
Other1-$0$0Oct 25, 1972--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other1-$0$0Oct 25, 1972--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Other3-$50$50Oct 25, 1972--
010051910.252
General requirements
OSHA citation code: 19100252 B04
Other1-$0$0Oct 25, 1972--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.95Occupational Noise Exposure4 citations · $1,250
1910.373 citations · $500
1910.219Mechanical Power-Transmission Apparatus3 citations · $50

Chemical exposure sampling

Samples
17
Substances
12
Inspections
1

Other inspected employers in Reedsburg, WI

All employers in Reedsburg →