Skip to content
SafetyRecord logoSafetyRecord
MOBAC INC.
$6,800
penalties
7
viol.
3
insp.

MOBAC INC.

BALTO PIKE AND ORCHARD RD, KENNETT SQUARE, PA 19348NAICS 236220 Commercial and Institutional Building Construction

Inspections
3
Nov 1981 to Oct 2011 · 3 safety, 0 health
Violations
7
across 3 inspections
Penalties on record
$6,800
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 28, 2011Planned (H) · Partial scope, Safety#315818211$6,8006 viol.

Inspection #315818211

Dates

Opened
Oct 28, 2011
Closing Conference Date
Oct 28, 2011
Closed
Jun 4, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$11,400
Penalties on Record
$6,800
Site Address
145 S. Walnut Street, Kennett Square, PA 19348
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01 VII
Serious13$4,200$3,000Jan 27, 2012--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 F07
Serious13$0$0Jan 27, 2012--
01001C1926.454
Scaffolding - Training
OSHA citation code: 19260454 B
Serious13$0$0Jan 27, 2012--
010021926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious13$4,200$2,000Jan 27, 2012--
01003A1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Serious11$3,000$1,800Jan 27, 2012--
01003B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious11$0$0Jan 27, 2012--
Jun 22, 1983Planned (H) · Complete scope, Safety#12682332$01 viol.

Inspection #12682332

Dates

Opened
Jun 22, 1983
Closing Conference Date
Jun 22, 1983
Closed
Aug 22, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Balto Pike And Orchard Rd, Kennett Square, PA 19348
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other1-$0$0Jul 2, 1983--
Nov 5, 1981Planned (H) · Complete scope, Safety#12565792$00 viol.

Inspection #12565792

Dates

Opened
Nov 5, 1981
Closing Conference Date
Nov 5, 1981
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
816 East Baltimore Pike, Kennett Square, PA 19348
Industry
236220 Commercial and Institutional Building Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements2 citations · $3,000
1903.2Posting of Notices; Availability of the Act, Regulations and Applicable Standards1 citation · $0
1926.403Electrical - General Requirements (Construction)1 citation · $1,800

Industry comparison

Violations per inspection
This employer2.3
Industry average1.5
Penalties per inspection
This employer$2,267
Industry average$1,285

Construction of Buildings, 202,579 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: nonresidential building construction reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 6.8%; NAICS 2362 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in KENNETT SQUARE, PA

All employers in KENNETT SQUARE →