MORGAN BRONZE PRODUCTS, INC.
367 HOLLOW HILL ROAD, WAUCONDA, IL 60084
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 24, 2008#312567852Sep 24, 2008Planned (H) · Partial scope, Safety#312567852$4,4503 viol.3 violations$4,450 in penalties
Inspection #312567852
Dates
- Opened
- Sep 24, 2008
- Closing Conference Date
- Sep 24, 2008
- Closed
- Dec 2, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 66
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $4,450
- Penalties on Record
- $4,450
- Site Address
- 367 Hollow Hill Drive, Wauconda, IL 60084
- Industry
- 332919 Other Metal Valve and Pipe Fitting Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 IA | Serious | 2 | 2 | $1,250 | $1,250 | Nov 4, 2008 | - | - |
| 01002 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 A06 | Serious | 1 | 42 | $700 | $700 | Nov 19, 2008 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 6 | 10 | $2,500 | $2,500 | Nov 4, 2008 | - | - |
Nov 7, 2005#309464857Nov 7, 2005Complaint (B) · Partial scope, Health#309464857$2,9404 viol.4 violations$2,940 in penalties
Inspection #309464857
Dates
- Opened
- Nov 7, 2005
- Closing Conference Date
- Nov 7, 2005
- Closed
- Dec 16, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 52
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $4,200
- Penalties on Record
- $2,940
- Site Address
- 367 Hollow Hill Road, Wauconda, IL 60084
- Industry
- 332510 Hardware Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.138 Hand Protection OSHA citation code: 19100138 A | Serious | 2 | 2 | $2,100 | $1,470 | Dec 7, 2005 | - | - |
| 01002A | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 2 | 2 | $2,100 | $1,470 | Dec 7, 2005 | - | - |
| 01002B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 2 | 2 | $0 | $0 | Dec 7, 2005 | - | - |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 I | Other | 1 | 2 | $0 | $0 | Dec 7, 2005 | - | - |
Feb 4, 2004#307387407Feb 4, 2004Planned (H) · Complete scope, Health#307387407$1,9504 viol.4 violations$1,950 in penalties
Inspection #307387407
Dates
- Opened
- Feb 4, 2004
- Closing Conference Date
- Feb 6, 2004
- Closed
- Jul 26, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 42
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $3,900
- Penalties on Record
- $1,950
- Site Address
- 367 Hollow Hill Road, Wauconda, IL 60084
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 5 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 5 | 0 | mg/m³ |
| Cadmium | 5 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 5 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 5 | 0 | mg/m³ |
| Copper Fume (as Cu) | 5 | 0 - 0.0058537 | mg/m³ |
| Iron Oxide Fume | 5 | 0 | mg/m³ |
| Lead, Inorganic (as Pb) | 5 | 0 - 0.006471 | mg/m³ |
| Manganese Fume (as Mn) | 5 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 5 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 5 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 5 | 0 | mg/m³ |
| Zinc Oxide Fume | 5 | 0 | mg/m³ |
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | 1 | 7 | $900 | $450 | Mar 18, 2004 | - | - |
| 01002 | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Serious | 1 | 42 | $1,500 | $750 | Mar 9, 2004 | - | - |
| 01003A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 42 | $1,500 | $750 | Mar 9, 2004 | - | - |
| 01003B | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Serious | 1 | 6 | $0 | $0 | Mar 9, 2004 | - | - |
Jan 27, 2004#307387126Jan 27, 2004Planned (H) · Complete scope, Safety#307387126$9003 viol.3 violations$900 in penalties
Inspection #307387126
Dates
- Opened
- Jan 27, 2004
- Closing Conference Date
- Jan 29, 2004
- Closed
- May 24, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 42
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $1,800
- Penalties on Record
- $900
- Site Address
- 367 Hollow Hill Road, Wauconda, IL 60084
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 2 | 1 | $900 | $450 | Mar 19, 2004 | - | - |
| 01001B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 1 | $0 | $0 | Mar 19, 2004 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F01 | Serious | 2 | 1 | $900 | $450 | Mar 19, 2004 | - | - |
Sep 12, 2003#307025502Sep 12, 2003Planned (H) · Partial scope, Safety#307025502$00 viol.0 violations$0 in penalties
Inspection #307025502
Dates
- Opened
- Sep 12, 2003
- Closing Conference Date
- Sep 12, 2003
- Closed
- Sep 12, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 42
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 367 Hollow Hill Road, Wauconda, IL 60084
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Mar 1, 2001#122494255Mar 1, 2001Planned (H) · Partial scope, Safety#122494255$8572 viol.2 violations$857 in penalties
Inspection #122494255
Dates
- Opened
- Mar 1, 2001
- Closing Conference Date
- Mar 7, 2001
- Closed
- Jun 11, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $1,225
- Penalties on Record
- $857
- Site Address
- 367 Hollow Hill Road, Wauconda, IL 60084
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 4 | $700 | $490 | Apr 26, 2001 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 3 | 1 | $525 | $367 | May 12, 2001 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 2001 to 2008. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.