Skip to content
SafetyRecord logoSafetyRecord
NATRL WIND GAP, INC.
$9,040
penalties
46
viol.
2
insp.

NATRL WIND GAP, INC.

MALE ROAD, WIND GAP, PA 18091

Inspections
2
Sep 1994 to Sep 1994 · 1 safety, 1 health
Violations
46
across 2 inspections
Penalties on record
$9,040
latest amounts in DOL records
By classification
Serious 38Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 13, 1994Complaint (B) · Partial scope, Health#122023161$5,04021 viol.

Inspection #122023161

Dates

Opened
Sep 13, 1994
Closing Conference Date
Nov 16, 1994
Closed
Apr 26, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11
Related Activity
2 complaints

Violations and Penalties

Total Violations
21
Violation Types
16 serious, 5 other-than-serious
Initial Penalties
$8,400
Penalties on Record
$5,040
Site Address
Male Road, Wind Gap, PA 18091
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Benzene100.0465 - 13.0574ppm
Petroleum Distillates (Naphtha) (Rubber Solvent)100.2959 - 133.3158mg/m³

Violations

Violation list (21 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious13$450$270Dec 6, 1994--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious111$450$270Dec 6, 1994--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious111$0$0Dec 6, 1994--
020011910.303
OSHA citation code: 19100303 G01
Other13$0$0Nov 10, 1994--
03001A1910.1028
Benzene
OSHA citation code: 19101028 C01
Serious13$1,500$900Apr 3, 1995--
03001B1910.1028
Benzene
OSHA citation code: 19101028 F01 I
Serious13$0$0Apr 6, 1995--
03001C1910.1028
Benzene
OSHA citation code: 19101028 G01 I
Serious13$0$0Dec 9, 1994--
03001D1910.1028
Benzene
OSHA citation code: 19101028 G03
Serious13$0$0Jan 3, 1995--
03001E1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Serious13$0$0Dec 9, 1994--
03001F1910.134
Respiratory Protection
OSHA citation code: 19100134 B05
Serious13$0$0Dec 9, 1994--
03001G1910.1028
Benzene
OSHA citation code: 19101028 G04 I
Serious13$0$0Dec 9, 1994--
03001H1910.1028
Benzene
OSHA citation code: 19101028 G05 I
Serious13$0$0Dec 19, 1994--
03002A1910.1028
Benzene
OSHA citation code: 19101028 D01
Serious13$1,500$900Dec 9, 1994--
03002B1910.1028
Benzene
OSHA citation code: 19101028 J01 I
Serious11$0$0Dec 13, 1994--
030031910.1028
Benzene
OSHA citation code: 19101028 F02 I
Serious13$1,500$900Jan 3, 1995--
030041910.1028
Benzene
OSHA citation code: 19101028 J03 I
Serious13$1,500$900Dec 19, 1994--
030051910.1028
Benzene
OSHA citation code: 19101028 I01 I
Serious13$1,500$900Jan 17, 1995--
040011910.1028
Benzene
OSHA citation code: 19101028 E02 I
Other13$0$0Dec 9, 1994--
040021910.1028
Benzene
OSHA citation code: 19101028 J01 II
Other13$0$0Dec 9, 1994--
040031910.1028
Benzene
OSHA citation code: 19101028 J03 IIIA
Other13$0$0Dec 9, 1994--
040041910.1028
Benzene
OSHA citation code: 19101028 J03 IIIB
Other13$0$0Dec 9, 1994--
Sep 13, 1994Complaint (B) · Partial scope, Safety#122023153$4,00025 viol.

Inspection #122023153

Dates

Opened
Sep 13, 1994
Closing Conference Date
Sep 13, 1994
Closed
Apr 26, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11
Related Activity
1 complaint

Violations and Penalties

Total Violations
25
Violation Types
22 serious, 3 other-than-serious
Initial Penalties
$6,900
Penalties on Record
$4,000
Site Address
Male Road, Wind Gap, PA 18091
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (25 of 25 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious11$600$330Sep 28, 1994--
01001B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Serious11$0$0Sep 28, 1994--
01002A1910.303
OSHA citation code: 19100303 G02 I
Serious111$600$350Sep 23, 1994--
01002B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G01 II
Serious111$0$0Sep 23, 1994--
01002C1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 J01 I
Serious111$0$0Sep 28, 1994--
010031910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Serious111$600$350Sep 28, 1994--
01004A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 D04 I
Serious111$600$350Nov 6, 1994--
01004B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 D03
Serious111$0$0Sep 28, 1994--
01004C1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious111$0$0Nov 6, 1994--
01004D1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 IV
Serious111$0$0Nov 6, 1994--
010051910.23
OSHA citation code: 19100023 C01
Serious211$600$350Oct 14, 1994--
010061910.23
OSHA citation code: 19100023 A08
Serious111$600$350Sep 28, 1994--
010071910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M05 I
Serious111$600$350Sep 28, 1994--
010081910.136
Foot Protection
OSHA citation code: 19100136 A
Serious111$600$350Oct 7, 1994--
010091910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious311$600$350Oct 7, 1994--
01010A1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 A
Serious111$600$350Nov 6, 1994--
01010B1910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B01
Serious111$0$0Nov 6, 1994--
01010C1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02
Serious111$0$0Nov 6, 1994--
01010D1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 I
Serious111$0$0Nov 6, 1994--
01010E1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 IIIA
Serious111$0$0Nov 6, 1994--
010111910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious111$450$260Oct 7, 1994--
010121910.23
OSHA citation code: 19100023 D01 III
Serious11$450$260Sep 28, 1994--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Other111$0$0Oct 7, 1994--
020021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 A02 IIIF
Other111$0$0Sep 28, 1994--
020031910.303
OSHA citation code: 19100303 F
Other111$0$0Oct 14, 1994--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1028Benzene15 citations · $4,500
1910.234 citations · $1,230
1910.333Electrical - Selection and Use of Work Practices4 citations · $350

Chemical exposure sampling

Samples
20
Substances
2
Inspections
1

Other inspected employers in WIND GAP, PA