Skip to content
SafetyRecord logoSafetyRecord
NEW ENGLAND CONCRETE PIPE CORP.
$13,956
penalties
35
viol.
5
insp.

NEW ENGLAND CONCRETE PIPE CORP.

69 NECK RD, Westfield, MA 01085

Inspections
5
Jun 1977 to Jul 1993 · 1 safety, 4 health
Violations
35
across 5 inspections
Penalties on record
$13,956
latest amounts in DOL records
By classification
Serious 17Willful 3Repeat 0Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 1, 1993Follow-Up (F) · Partial scope, Health#17830811$3,8266 viol.

Inspection #17830811

Dates

Opened
Jul 1, 1993
Closing Conference Date
Aug 10, 1993
Closed
Mar 7, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
33

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$7,650
Penalties on Record
$3,826
Site Address
69 Neck Road, Westfield, MA 01085
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Silica, Crystalline Quartz (Respirable Fraction)20 - 1.1%

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious24$1,700$850Sep 9, 1993--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 II
Serious324$1,275$850Sep 9, 1993--
010031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 D04 I
Serious12$1,700$638Sep 9, 1993--
01004A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M02
Serious11$1,700$850Sep 10, 1993--
01004B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M05 III
Serious11$0$0Sep 10, 1993--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious13$1,275$638Sep 9, 1993--
Feb 5, 1991Referral (C) · Partial scope, Health#107451981$9,98012 viol.

Inspection #107451981

Dates

Opened
Feb 5, 1991
Closing Conference Date
Feb 27, 1991
Contested
Apr 15, 1991
Final Order
Nov 5, 1992
Closed
Oct 25, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
21
Related Activity
1 referral

Violations and Penalties

Total Violations
12
Violation Types
8 serious, 3 willful, 1 other-than-serious
Initial Penalties
$9,980
Penalties on Record
$9,980
Site Address
69 Neck Road, Westfield, MA 01085
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (10 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious48$630$500Mar 23, 1991Apr 15, 1991Nov 5, 1992
010021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Serious23$720$500Mar 29, 1991Apr 15, 1991Nov 5, 1992
010031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious48$450$500Mar 29, 1991Apr 15, 1991Nov 5, 1992
010041910.132
General requirements
OSHA citation code: 19100132 A
Serious15$450$500Apr 26, 1991Apr 15, 1991Nov 5, 1992
010051910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious114$540$500Apr 26, 1991Apr 15, 1991Nov 5, 1992
010061910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 N03 VI
Serious15$720$500Mar 27, 1991Apr 15, 1991Nov 5, 1992
010071910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$270$500Apr 16, 1991Apr 15, 1991Nov 5, 1992
010081910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious12$180$500Mar 23, 1991Apr 15, 1991Nov 5, 1992
02001A1910.1000
Air Contaminants
OSHA citation code: 19101000 A03
Willful15$3,010$2,990Mar 23, 1991Apr 15, 1991Nov 5, 1992
02001B1910.1000
Air Contaminants
OSHA citation code: 19101000 F02 I
Willful15$0$0May 25, 1991Apr 15, 1991Nov 5, 1992

Showing the 10 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 10, 1986Planned (H) · Complete scope, Safety#101406155$1508 viol.

Inspection #101406155

Dates

Opened
Oct 10, 1986
Closing Conference Date
Oct 10, 1986
Closed
Apr 8, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
16

Violations and Penalties

Total Violations
8
Violation Types
3 serious, 5 other-than-serious
Initial Penalties
$150
Penalties on Record
$150
Site Address
69 Neck Rd., Westfield, MA 01085
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$60$60Nov 25, 1986--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious11$30$30Nov 25, 1986--
010031910.303
OSHA citation code: 19100303 G02 I
Serious22$60$60Oct 24, 1986--
020011910.22
OSHA citation code: 19100022 A01
Other12$0$0Nov 25, 1986--
020021910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 D10
Other116$0$0Nov 3, 1986--
020031910.303
OSHA citation code: 19100303 F
Other32$0$0Oct 24, 1986--
020041910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Other11$0$0Nov 3, 1986--
020051910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other11$0$0Nov 3, 1986--
Aug 22, 1977Follow-Up (F) · Complete scope, Health#10636801$02 viol.

Inspection #10636801

Dates

Opened
Aug 22, 1977
Closing Conference Date
Aug 22, 1977
Closed
Oct 14, 1977

Inspection

Advance Notice
Yes
Owner Type
Not recorded
Union Status
Yes
Number of Employees
27

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
69 Neck Rd, Westfield, MA 01085
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 B01
Other2-$0$0Sep 6, 1977--
010021910.309
OSHA citation code: 19100309 A 011017
Other1-$0$0Sep 12, 1977--
Jun 29, 1977Planned (H) · Complete scope, Health#10636728$07 viol.

Inspection #10636728

Dates

Opened
Jun 29, 1977
Closing Conference Date
Jul 6, 1977
Closed
Aug 22, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
28

Violations and Penalties

Total Violations
7
Violation Types
7 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
69 Neck Rd, Westfield, MA 01085
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.104
Oxygen
OSHA citation code: 19100104 B08 VIII
Other1-$0$0Aug 1, 1977--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Other1-$0$0Aug 8, 1977--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other1-$0$0Aug 8, 1977--
010041910.252
General requirements
OSHA citation code: 19100252 A02 IIB
Other1-$0$0Aug 1, 1977--
010051910.252
General requirements
OSHA citation code: 19100252 A02 IVC
Other1-$0$0Aug 1, 1977--
010061910.252
General requirements
OSHA citation code: 19100252 C02 IV
Other1-$0$0Aug 8, 1977--
010071910.309
OSHA citation code: 19100309 B 037404
Other1-$0$0Jul 21, 1977--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)3 citations · $1,198
1910.147The control of hazardous energy (lockout/tagout)3 citations · $1,988
1910.252General requirements3 citations · $0

Chemical exposure sampling

Samples
2
Substances
1
Inspections
1

Other inspected employers in Westfield, MA

All employers in Westfield →