Skip to content
SafetyRecord logoSafetyRecord
NORTHERN METAL FAB., INC.
$132,454
penalties
86
viol.
11
insp.

NORTHERN METAL FAB., INC.

510 VANDEBERG ST., BALDWIN, WI 54002NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
11
Apr 1997 to Apr 2024 · 8 safety, 3 health
Violations
86
across 11 inspections
Penalties on record
$132,454
latest amounts in DOL records
By classification
Serious 63Willful 4Repeat 1Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 8, 1997Complaint (B) · Complete scope, Health#106052244$18,87523 viol.

Inspection #106052244

Dates

Opened
Apr 8, 1997
Closing Conference Date
Apr 22, 1997
Closed
Mar 31, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40
Related Activity
1 complaint

Violations and Penalties

Total Violations
23
Violation Types
19 serious, 1 willful, 3 other-than-serious
Initial Penalties
$46,750
Penalties on Record
$18,875
Site Address
510 Vandeberg St., Baldwin, WI 54002
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling4 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC211 - 13mg/m³
Sample WeightQC23.504 - 6.087mg
Silica, Crystalline Quartz (Respirable Fraction)221 - 27%
Toluene20 - 1162.1ppm
VM and P Naphtha20 - 2175.61mg/m³
Xylene20 - 1051.41ppm

Violations

Violation list (23 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.94
Ventilation
OSHA citation code: 19100094 A02 II
Serious11$2,500$750Oct 22, 1997--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious11$0$0Oct 22, 1997--
01001C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious1-$0$0Oct 22, 1997--
01002D1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Serious11$0$1,000Jul 28, 1997--
01002E1910.134
Respiratory Protection
OSHA citation code: 19100134 B07
Serious11$0$0Jul 28, 1997--
01002F1910.134
Respiratory Protection
OSHA citation code: 19100134 B08
Serious11$0$0Jul 28, 1997--
01002G1910.134
Respiratory Protection
OSHA citation code: 19100134 B09
Serious22$0$0Jul 28, 1997--
01002H1910.134
Respiratory Protection
OSHA citation code: 19100134 B10
Serious11$0$0Jul 28, 1997--
010031910.106
Flammable Liquids
OSHA citation code: 19100106 D04 IV
Serious12$1,000$500Aug 28, 1997--
01004A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Serious13$2,500$1,250Jun 16, 1997--
01004B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Serious35$0$0Jun 16, 1997--
01004C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C08
Serious11$0$0Jun 16, 1997--
01004D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious11$0$0Jun 16, 1997--
01005A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G05
Serious32$2,500$1,250Jun 16, 1997--
01005B1910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious12$0$0Jun 13, 1997--
01006A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious23$1,250$625Jul 28, 1997--
01006B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D
Serious11$0$0Jun 27, 1997--
010071910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$1,250$625Jul 28, 1997--
010081910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious12$750$375Jun 13, 1997--
020011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Willful13$35,000$12,500Jul 28, 1997--
030011910.94
Ventilation
OSHA citation code: 19100094 A07
Other21$0$0Jun 27, 1997--
030021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 I
Other11$0$0Jun 13, 1997--
030031910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J01 II
Other110$0$0Jul 28, 1997--
Inspections 11 to 11 of 11, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)11 citations · $5,313
1910.134Respiratory Protection8 citations · $1,500
1910.212General Requirements for All Machines (Machine Guarding)7 citations · $13,920

Chemical exposure sampling

Samples
12
Substances
6
Inspections
1

Industry comparison

Violations per inspection
This employer7.8
Industry average3.3
Penalties per inspection
This employer$12,041
Industry average$2,287

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in BALDWIN, WI