Skip to content
SafetyRecord logoSafetyRecord
OVERHEAD DOOR CORPORATION-NEBRASKA DIV.
$44,154
penalties
31
viol.
8
insp.

OVERHEAD DOOR CORPORATION-NEBRASKA DIV.

2514 EAST HWY. 30, Grand Island, NE 68801NAICS 332321 Metal Window and Door Manufacturing

Inspections
8
Jun 1998 to Jan 2012 · 6 safety, 2 health
Violations
31
across 8 inspections
Penalties on record
$44,154
latest amounts in DOL records
By classification
Serious 20Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 6, 2012Planned (H) · Partial scope, Safety#316018977$8,0003 viol.

Inspection #316018977

Dates

Opened
Jan 6, 2012
Closing Conference Date
Jan 6, 2012
Closed
Jun 21, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
204

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$15,000
Penalties on Record
$8,000
Site Address
2514 E. Hwy 30, Grand Island, NE 68801
Industry
311513 Cheese Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$5,000$3,000Apr 6, 2012--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IB
Serious23$5,000$5,000Apr 27, 2012--
010041910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 I
Serious13$5,000$0Apr 6, 2012--
Jan 7, 2010Planned (H) · Complete scope, Health#311469720$12,1902 viol.

Inspection #311469720

Dates

Opened
Jan 7, 2010
Closing Conference Date
Feb 9, 2010
Closed
Mar 31, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
230

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$15,475
Penalties on Record
$12,190
Site Address
2514 E. Hwy 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone69.55767 - 34.373205ppm

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other13$2,975$2,975Mar 1, 2010--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Other110$12,500$9,215Mar 15, 2010--
Oct 21, 2008Planned (H) · Complete scope, Safety#311463889$17,25011 viol.

Inspection #311463889

Dates

Opened
Oct 21, 2008
Closing Conference Date
Oct 23, 2008
Closed
Dec 19, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
290

Violations and Penalties

Total Violations
11
Violation Types
7 serious, 4 other-than-serious
Initial Penalties
$33,000
Penalties on Record
$17,250
Site Address
2514 E. Hwy 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 B01
Other16$2,000$1,000Nov 13, 2008--
010021910.176
Handling Materials - General
OSHA citation code: 19100176 B
Other16$2,000$1,000Nov 13, 2008--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$5,000$2,500Nov 13, 2008--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious51$2,500$2,500Nov 13, 2008--
010061910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious11$2,000$2,000Nov 13, 2008--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01 I
Other11$2,500$750Nov 13, 2008--

Showing the 6 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 29, 2006Complaint (B) · Partial scope, Safety#308681055$00 viol.

Inspection #308681055

Dates

Opened
Mar 29, 2006
Closing Conference Date
Mar 29, 2006
Closed
May 19, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
250
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2514 East Hwy. 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Apr 14, 2004Planned (H) · Partial scope, Safety#306020678$9381 viol.

Inspection #306020678

Dates

Opened
Apr 14, 2004
Closing Conference Date
Apr 15, 2004
Closed
Apr 29, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
267

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,875
Penalties on Record
$938
Site Address
2514 East Hwy. 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious11$1,875$938Apr 22, 2004--
Sep 6, 2001Planned (H) · Complete scope, Safety#303728505$1,2763 viol.

Inspection #303728505

Dates

Opened
Sep 6, 2001
Closing Conference Date
Sep 7, 2001
Closed
Sep 18, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
325

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$2,550
Penalties on Record
$1,276
Site Address
2514 East Hwy. 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious15$1,275$638Sep 19, 2001--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious14$1,275$638Sep 19, 2001--
020011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Other11$0$0Sep 19, 2001--
Sep 6, 2001Planned (H) · Complete scope, Health#303728489$03 viol.

Inspection #303728489

Dates

Opened
Sep 6, 2001
Closing Conference Date
Sep 7, 2001
Closed
Sep 17, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
325

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2514 East Hwy. 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other110$0$0Sep 14, 2001--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other150$0$0Sep 14, 2001--
010031910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other11$0$0Sep 14, 2001--
Jun 25, 1998Planned (H) · Partial scope, Safety#300052693$4,5008 viol.

Inspection #300052693

Dates

Opened
Jun 25, 1998
Closing Conference Date
Jun 25, 1998
Closed
Aug 5, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
220

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$9,000
Penalties on Record
$4,500
Site Address
2514 East Hwy. 30, Grand Island, NE 68801
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$2,500$1,250Jul 31, 1998--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious23$2,500$1,250Jul 31, 1998--
01003A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious61$2,500$1,250Jul 31, 1998--
01003B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 ID
Serious21$0$0Jul 31, 1998--
01004A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 D06 I
Serious11$1,500$750Jul 31, 1998--
01004B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 I
Serious11$0$0Jul 31, 1998--

Showing the 6 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)7 citations · $14,113
1910.217Mechanical Power Presses7 citations · $7,000
1910.213Woodworking Machinery Requirements2 citations · $2,000

Chemical exposure sampling

Samples
6
Substances
1
Inspections
1

Industry comparison

Violations per inspection
This employer3.9
Industry average3.3
Penalties per inspection
This employer$5,519
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,936 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Grand Island, NE

All employers in Grand Island →