Skip to content
SafetyRecord logoSafetyRecord
PAIGE MECHANICAL GROUP, INC.
$12,831
penalties
4
viol.
4
insp.

PAIGE MECHANICAL GROUP, INC.

805 N ROOSEVELT ST, BOISE, ID 83706NAICS 238220 Plumbing, Heating, and Air-Conditioning Contractors

Inspections
4
Jun 2009 to Sep 2023 · 3 safety, 1 health
Violations
4
across 4 inspections
Penalties on record
$12,831
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 14, 2023Planned (H) · Partial scope, Health#346975329$00 viol.

Inspection #346975329

Dates

Opened
Sep 14, 2023
Closing Conference Date
Sep 14, 2023
Closed
Nov 9, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
805 N Roosevelt St, Boise, ID 83706
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 19, 2016Other (L) · Partial scope, Safety#341809689$11,2241 viol.

Inspection #341809689

Dates

Opened
Jul 19, 2016
Closing Conference Date
Jul 19, 2016
Final Order
Dec 5, 2016
Closed
Jun 13, 2017

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
140

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$11,224
Penalties on Record
$11,224
Site Address
1910 University Dr, Boise, ID 83725
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Other Inspection: This inspection record is categorized as Other-L in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 A03
Serious12$11,224$11,224Dec 2, 2016-Dec 5, 2016
May 18, 2015Planned (H) · Partial scope, Safety#340668466$1,6072 viol.

Inspection #340668466

Dates

Opened
May 18, 2015
Closing Conference Date
May 18, 2015
Final Order
Jul 29, 2015
Closed
Oct 1, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,607
Penalties on Record
$1,607
Site Address
Ingalls And Ellsworth, Gowen Field, Boise, ID 83705
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious12$1,607$1,607Jul 27, 2015-Jul 29, 2015
01001B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious12$0$0Jul 27, 2015-Jul 29, 2015
Jun 11, 2009Planned (H) · Complete scope, Safety#313348054$01 viol.

Inspection #313348054

Dates

Opened
Jun 11, 2009
Closing Conference Date
Jun 11, 2009
Closed
Oct 26, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1105 N 13th Street, Boise, ID 83702
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Other11$0$0Aug 19, 2009--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication1 citation · $0
1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $1,607
1926.405Electrical - Wiring Methods (Construction)1 citation · $0

Industry comparison

Violations per inspection
This employer1.0
Industry average2.1
Penalties per inspection
This employer$3,208
Industry average$2,530

Specialty Trade Contractors, 551,694 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: plumbing, heating, and air-conditioning contractors reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.2%; NAICS 23822 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in BOISE, ID

All employers in BOISE →