PARRETT MANUFACTURING, INC.
$4,130
penalties
11
viol.
2
insp.

PARRETT MANUFACTURING, INC.

810 2ND AVE. EAST, DORCHESTER, WI 54425NAICS 321911 Wood Window and Door Manufacturing

Inspections
2
Jan 2010 to Feb 2010 · 1 safety, 1 health
Violations
11
across 2 inspections
Penalties on record
$4,130
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 10, 2010Referral (C) · Partial scope, Health#313176802$3,1505 viol.

Inspection #313176802

Dates

Opened
Feb 10, 2010
Closing Conference Date
Feb 11, 2010
Closed
Jan 5, 2011

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
No
Number of Employees
97
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$4,500
Penalties on Record
$3,150
Site Address
810 2nd Avenue E, Dorchester, WI 54425
Industry
321911 Wood Window and Door Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling8 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Acetone60.16138 - 6.025945ppm
Diisobutyl Ketone20ppm
Ethyl Benzene60 - 0.072419ppm
Gravimetric DeterminationQC10.1297mg/m³
Methyl (n-amyl) ketone60.044096 - 0.328169ppm
n-Butyl Acetate60.152067 - 1.917692ppm
Particulates not otherwise regulated (Respirable Fraction)10.1297mg/m³
Sample WeightQC10.097mg
Stoddard Solvent30 - 5.853478mg/m³
VM and P Naphtha30mg/m³

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious397$1,250$875Dec 31, 2010--
010021910.106
Flammable Liquids
OSHA citation code: 19100106 D04 I
Serious197$1,250$875Oct 16, 2010--
01003A1910.125
Additional Requirements for Dipping and Coating Operations Using Flammable Liquids
OSHA citation code: 19100125 A
Serious11$1,250$875Aug 26, 2010--
01003C1910.125
Additional Requirements for Dipping and Coating Operations Using Flammable Liquids
OSHA citation code: 19100125 F02 II
Serious11$0$0Sep 23, 2010--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious197$750$525Aug 12, 2010--
Jan 20, 2010Planned (H) · Partial scope, Safety#313176588$9806 viol.

Inspection #313176588

Dates

Opened
Jan 20, 2010
Closing Conference Date
Jan 20, 2010
Closed
Jun 17, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
97

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$700
Penalties on Record
$980
Site Address
810 2nd Ave. East, Dorchester, WI 54425
Industry
321911 Wood Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious22$0$490May 26, 2010--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious11$700$490Jun 2, 2010--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other24$0$0May 26, 2010--
020021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other13$0$0May 19, 2010--
020031910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B05
Other16$0$0May 26, 2010--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other12$0$0May 26, 2010--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $490
1910.125Additional Requirements for Dipping and Coating Operations Using Flammable Liquids2 citations · $875
1910.22Walking-Working Surfaces - General Requirements2 citations · $0

Chemical exposure sampling

Samples
35
Substances
10
Inspections
1

Industry comparison

Violations per inspection
This employer5.5
Industry average3.4
Penalties per inspection
This employer$2,065
Industry average$2,533

Wood Product Manufacturing, 17,977 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: wood window and door manufacturing reported 3.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 8.1%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in DORCHESTER, WI

All employers in DORCHESTER →