Skip to content
SafetyRecord logoSafetyRecord
PATTERN ENGINEERING COMPANY
$0
penalties
0
viol.
5
insp.

PATTERN ENGINEERING COMPANY

, West Palm Beach, FL 00000

Inspections
5
Feb 1984 to Nov 1991 · 4 safety, 1 health
Violations
0
no violations cited
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 0Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 26, 1991Planned (H) · No Inspection scope, Safety#108997099$00 viol.

Inspection #108997099

Dates

Opened
Nov 26, 1991
Closing Conference Date
Nov 26, 1991
Closed
Dec 4, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2705-09 Division Avenue, West Palm Beach, FL 33407
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 19, 1987Planned (H) · Complete scope, Safety#101164465$00 viol.

Inspection #101164465

Dates

Opened
May 19, 1987
Closing Conference Date
Sep 10, 1987
Closed
Sep 11, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2705-09 Division Avenue, West Palm Beach, FL 33407
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 23, 1985Planned (H) · Complete scope, Health#2306504$00 viol.

Inspection #2306504

Dates

Opened
Apr 23, 1985
Closing Conference Date
Jul 2, 1985
Closed
Aug 13, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2705-09 Division Avenue, West Palm Beach, FL 33407
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20.0117 - 0.0161mg/m³
Cresol (All Isomers)30mg/m³
Iron Oxide Fume20.1172 - 0.1302mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)30mg/m³
Phenol30mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20.0091 - 0.0114mg/m³
Apr 13, 1984Programmed Related (I) · Complete scope, Safety#1652775$00 viol.

Inspection #1652775

Dates

Opened
Apr 13, 1984
Closing Conference Date
Apr 24, 1984
Closed
Apr 24, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2705 Division Avenue, West Palm Beach, FL 33402
Industry
Not classified in OSHA's inspection record.

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Feb 7, 1984Planned (H) · No Inspection scope, Safety#18758482$00 viol.

Inspection #18758482

Dates

Opened
Feb 7, 1984
Closing Conference Date
Not recorded
Closed
Mar 16, 2016

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
, West Palm Beach, FL 00000
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Chemical exposure sampling

Samples
35
Substances
16
Inspections
1

Other inspected employers in West Palm Beach, FL