Skip to content
SafetyRecord logoSafetyRecord
PERFORMANCE ENGINEERING MANUFACTURING
$2,275
penalties
17
viol.
4
insp.

PERFORMANCE ENGINEERING MANUFACTURING

1212 NORTH NORDBECK STREET, HIGHWAY 50, VERMILLION, SD 57069

Inspections
4
Oct 1996 to Aug 2001 · 4 safety, 0 health
Violations
17
across 4 inspections
Penalties on record
$2,275
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 28, 2001Planned (H) · No Inspection scope, Safety#102762705$00 viol.

Inspection #102762705

Dates

Opened
Aug 28, 2001
Closing Conference Date
Aug 28, 2001
Closed
Sep 5, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1212 North Nordbeck Street, Highway 50, Vermillion, SD 57069
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jan 28, 1998Complaint (B) · Complete scope, Safety#113333462$9002 viol.

Inspection #113333462

Dates

Opened
Jan 28, 1998
Closing Conference Date
Jan 28, 1998
Closed
Apr 21, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$1,800
Penalties on Record
$900
Site Address
1212 North Nordbeck Street, Highway 50, Vermillion, SD 57069
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$1,800$900Feb 6, 1998--
020011910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Other21$0$0Feb 10, 1998--
Mar 11, 1997Follow-Up (F) · Complete scope, Safety#113331367$00 viol.

Inspection #113331367

Dates

Opened
Mar 11, 1997
Closing Conference Date
Mar 11, 1997
Closed
May 16, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1212 North Nordbeck Street, Highway 50, Vermillion, SD 57069
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 8, 1996Complaint (B) · Complete scope, Safety#113333926$1,37515 viol.

Inspection #113333926

Dates

Opened
Oct 8, 1996
Closing Conference Date
Oct 8, 1996
Closed
May 16, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
38
Related Activity
1 complaint

Violations and Penalties

Total Violations
15
Violation Types
12 serious, 3 other-than-serious
Initial Penalties
$2,750
Penalties on Record
$1,375
Site Address
1212 North Nordbeck Street, Highway 50, Vermillion, SD 57069
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Serious138$750$375Dec 20, 1996--
01001B1910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 F02 I
Serious938$0$0Dec 20, 1996--
01001C1910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 F02 II
Serious938$0$0Dec 20, 1996--
01001D1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Serious3838$0$0Dec 20, 1996--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious11$750$375Dec 20, 1996--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious11$0$0Dec 20, 1996--
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 II
Serious11$0$0Dec 20, 1996--
01002D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 IIB
Serious11$0$0Dec 20, 1996--
01002E1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 IIC2
Serious11$0$0Dec 20, 1996--
01002F1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 IID
Serious11$0$0Dec 20, 1996--
01002G1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious11$0$0Dec 20, 1996--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious33$1,250$625Dec 20, 1996--

Showing the 12 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties3 citations, $1,500 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 3 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01002G#113331367Mar 19, 1997$450--
01003#113331367Mar 19, 1997$750--

Showing the 2 FTA rows present in the first 12 citations on this inspection. OSHA's record shows 3 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)7 citations · $375
1910.110Storage and Handling of Liquefied Petroleum Gases2 citations · $0
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $1,525

Other inspected employers in VERMILLION, SD

All employers in VERMILLION →