Skip to content
SafetyRecord logoSafetyRecord
PERMIAN PIPE FABRICATION INC
$105
penalties
13
viol.
6
insp.

PERMIAN PIPE FABRICATION INC

1626 PROCTOR STREET, Odessa, TX 79761

Inspections
6
Nov 1974 to Mar 1987 · 4 safety, 2 health
Violations
13
across 6 inspections
Penalties on record
$105
latest amounts in DOL records
By classification
Serious 0Willful 0Repeat 0Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 5, 1987Planned (H) · Complete scope, Health#100719533$04 viol.

Inspection #100719533

Dates

Opened
Mar 5, 1987
Closing Conference Date
Mar 5, 1987
Closed
Apr 23, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4901 Trunk St., Odessa, TX 79762
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20 - 0.0033mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.0075mg/m³
Iron Oxide Fume20.5147 - 2.2597mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20.0335 - 0.313mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)30mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 A05 IV
Other12$0$0May 27, 1987--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Other318$0$0May 27, 1987--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other118$0$0May 27, 1987--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other12$0$0May 27, 1987--
Dec 4, 1985Planned (H) · No Inspection scope, Safety#100294768$00 viol.

Inspection #100294768

Dates

Opened
Dec 4, 1985
Closing Conference Date
Dec 4, 1985
Closed
Dec 4, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4901 Trunk St, Odessa, TX 79760
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 2, 1985Complaint (B) · Partial scope, Health#1451285$00 viol.

Inspection #1451285

Dates

Opened
Apr 2, 1985
Closing Conference Date
May 1, 1985
Closed
May 13, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4901 Trunk, Odessa, TX 79762
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Apr 2, 1985Complaint (B) · Partial scope, Safety#687657$00 viol.

Inspection #687657

Dates

Opened
Apr 2, 1985
Closing Conference Date
Apr 3, 1985
Closed
Apr 15, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4901 Trunk St, Odessa, TX 79762
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Dec 11, 1984Planned (H) · No Inspection scope, Safety#728170$00 viol.

Inspection #728170

Dates

Opened
Dec 11, 1984
Closing Conference Date
Dec 13, 1984
Closed
Dec 18, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
12 Proetor, Odessa, TX 79760
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 8, 1974Planned (H) · Partial scope, Safety#16979205$1059 viol.

Inspection #16979205

Dates

Opened
Nov 8, 1974
Closing Conference Date
Nov 8, 1974
Closed
Nov 22, 1974

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
50

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$105
Penalties on Record
$105
Site Address
1626 Proctor Street, Odessa, TX 79761
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.26
Dockboards
OSHA citation code: 19100026 C02 VIII
Other1-$0$0Dec 16, 1974--
010031910.106
Flammable Liquids
OSHA citation code: 19100106 G09
Other1-$0$0Dec 16, 1974--
010041910.151
Medical Services and First Aid
OSHA citation code: 19100151 B
Other1-$0$0Dec 16, 1974--
010051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01 IV
Other1-$0$0Dec 16, 1974--
010061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 A01
Other3-$0$0Dec 16, 1974--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other1-$25$25Dec 16, 1974--
010081910.309
OSHA citation code: 19100309 A 011014
Other1-$0$0Dec 16, 1974--
010091910.309
OSHA citation code: 19100309 A 025045
Other1-$25$25Dec 16, 1974--

Showing the 8 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.157Portable Fire Extinguishers2 citations · $0
1910.3092 citations · $25
1910.1200Hazard Communication2 citations · $0

Chemical exposure sampling

Samples
29
Substances
14
Inspections
1

Other inspected employers in Odessa, TX

All employers in Odessa →