Skip to content
SafetyRecord logoSafetyRecord
PLASCHEM SUPPLY AND CONSULTING INCORPORATED
$6,251
penalties
51
viol.
3
insp.

PLASCHEM SUPPLY AND CONSULTING INCORPORATED

1415 SPAR AVENUE, Anchorage, AK 99501NAICS 325211 Plastics Material and Resin Manufacturing

Inspections
3
Feb 1999 to Dec 2011 · 0 safety, 3 health
Violations
51
across 3 inspections
Penalties on record
$6,251
latest amounts in DOL records
By classification
Serious 37Willful 0Repeat 2Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 1, 2011Complaint (B) · Partial scope, Health#314288374$1,24010 viol.

Inspection #314288374

Dates

Opened
Dec 1, 2011
Closing Conference Date
Dec 2, 2011
Closed
Oct 29, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
3 serious, 2 repeat, 5 other-than-serious
Initial Penalties
$2,480
Penalties on Record
$1,240
Site Address
1415 Spar Avenue, Anchorage, AK 99501
Industry
327993 Mineral Wool Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious44$600$300Jun 19, 2012--
01002A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D05 I
Serious14$600$300Jun 19, 2012--
01002B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 E01
Serious14$0$0May 29, 2012--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Repeat34$80$40May 11, 2012--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 F01
Repeat14$1,200$600May 29, 2012--
030011910.37
OSHA citation code: 19100037 A03
Other11$0$0May 11, 2012--
030021910.37
OSHA citation code: 19100037 B05
Other11$0$0May 29, 2012--
030031910.132
General requirements
OSHA citation code: 19100132 D02
Other12$0$0May 11, 2012--
030041910.141
Sanitation
OSHA citation code: 19100141 G02
Other23$0$0May 29, 2012--
030051910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Other14$0$0May 29, 2012--
Dec 16, 2008Complaint (B) · Partial scope, Health#310852934$9007 viol.

Inspection #310852934

Dates

Opened
Dec 16, 2008
Closing Conference Date
Jan 20, 2009
Closed
Apr 23, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
2 serious, 5 other-than-serious
Initial Penalties
$2,025
Penalties on Record
$900
Site Address
1415 Spar Avenue, Anchorage, AK 99501
Industry
325211 Plastics Material and Resin Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D03 VI
Other14$1,500$0Mar 12, 2009--
01002B1910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious34$0$375Mar 5, 2009--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05
Serious44$0$375Mar 5, 2009--
010041910.106
OSHA citation code: 19100106 E02 II
Other34$225$0Mar 12, 2009--
020011904.32
Annual Summary
OSHA citation code: 19040032 A02
Other14$300$150Mar 26, 2009--
020021910.132
General requirements
OSHA citation code: 19100132 F01 V
Other14$0$0Mar 5, 2009--
020031910.141
Sanitation
OSHA citation code: 19100141 G04
Other14$0$0Mar 5, 2009--
Feb 9, 1999Complaint (B) · Complete scope, Health#301265252$4,11134 viol.

Inspection #301265252

Dates

Opened
Feb 9, 1999
Closing Conference Date
Mar 16, 1999
Closed
Nov 18, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
1 complaint

Violations and Penalties

Total Violations
34
Violation Types
32 serious, 2 other-than-serious
Initial Penalties
$8,216
Penalties on Record
$4,111
Site Address
1415 Spar Avenue, Anchorage, AK 99501
Industry
325211 Plastics Material and Resin Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Methyl Ethyl Ketone Peroxide40.1583 - 0.24mg/m³

Violations

Violation list (16 of 34 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious36$525$263May 1, 1999--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious16$525$263May 16, 1999--
010031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious24$225$113May 1, 1999--
01004A1910.307
Hazardous (classified) locations
OSHA citation code: 19100307 B
Serious16$1,500$750Sep 1, 1999--
01004B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious36$0$0Sep 1, 1999--
01005A1910.106
OSHA citation code: 19100106 E02 IIB1
Serious26$1,500$750Sep 1, 1999--
01005B1910.106
OSHA citation code: 19100106 E02 II
Serious26$0$0Sep 1, 1999--
01005C1910.38
OSHA citation code: 19100038 B03
Serious36$0$0Sep 1, 1999--
01006A1910.37
OSHA citation code: 19100037 K02
Serious16$375$188May 1, 1999--
01006B1910.37
OSHA citation code: 19100037 Q01
Serious16$0$0May 1, 1999--
01006C1910.37
OSHA citation code: 19100037 Q02
Serious16$0$0May 1, 1999--
01006D1910.37
OSHA citation code: 19100037 Q06
Serious36$0$0May 1, 1999--
01006E1910.36
OSHA citation code: 19100036 B06
Serious16$0$0May 1, 1999--
01007A1910.22
OSHA citation code: 19100022 D01
Serious26$450$225May 1, 1999--
01007B1910.23
OSHA citation code: 19100023 C01
Serious23$0$0May 1, 1999--
010081910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Serious13$1,500$750May 1, 1999--

Showing the 16 violations listed first by citation identifier. This inspection has 34 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.376 citations · $188
1910.146Permit-Required Confined Spaces4 citations · $1,050
1910.1200Hazard Communication4 citations · $1,238

Chemical exposure sampling

Samples
4
Substances
1
Inspections
1

Industry comparison

Violations per inspection
This employer17.0
Industry average2.8
Penalties per inspection
This employer$2,084
Industry average$3,815

Chemical Manufacturing, 11,966 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Anchorage, AK