Skip to content
SafetyRecord logoSafetyRecord
RCI PLUMBING CORP.
$14,576
penalties
7
viol.
5
insp.

RCI PLUMBING CORP.

346 W. 17TH ST, New York, NY 10011NAICS 238220 Plumbing, Heating, and Air-Conditioning Contractors

Inspections
5
Dec 2008 to Jul 2018 · 5 safety, 0 health
Violations
7
across 5 inspections
Penalties on record
$14,576
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 31, 2018Unprogrammed Related (G) · Complete scope, Safety#343353710$00 viol.

Inspection #343353710

Dates

Opened
Jul 31, 2018
Closing Conference Date
Jul 31, 2018
Closed
Jan 18, 2019

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
130 William St., New York, NY 10038
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Aug 11, 2017Programmed Related (I) · Partial scope, Safety#342593431$00 viol.

Inspection #342593431

Dates

Opened
Aug 11, 2017
Closing Conference Date
Aug 11, 2017
Closed
Aug 11, 2017

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
17 John Street, New York, NY 10038
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jan 12, 2016Programmed Related (I) · Complete scope, Safety#341189579$11,7003 viol.

Inspection #341189579

Dates

Opened
Jan 12, 2016
Closing Conference Date
Jan 12, 2016
Final Order
May 2, 2016
Closed
Dec 6, 2019

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
150

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$11,700
Penalties on Record
$11,700
Site Address
20 W. 40th Street, New York, NY 10018
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious11$4,500$4,500Apr 13, 2016-May 2, 2016
010021926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious11$3,600$3,600-May 2, 2016
010031926.1053
Ladders (Construction)
OSHA citation code: 19261053 B13
Serious11$3,600$3,600-May 2, 2016
Sep 9, 2010Programmed Related (I) · Complete scope, Safety#314881590$1,1262 viol.

Inspection #314881590

Dates

Opened
Sep 9, 2010
Closing Conference Date
Sep 9, 2010
Closed
Jan 24, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,500
Penalties on Record
$1,126
Site Address
346 W. 17th St, New York, NY 10011
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious11$750$563Sep 28, 2010--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious11$750$563Sep 28, 2010--
Dec 10, 2008Planned (H) · Complete scope, Safety#312931025$1,7502 viol.

Inspection #312931025

Dates

Opened
Dec 10, 2008
Closing Conference Date
Dec 11, 2008
Closed
May 26, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$2,500
Penalties on Record
$1,750
Site Address
250 East 49th Street, New York, NY 10017
Industry
238220 Plumbing, Heating, and Air-Conditioning Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious14$2,500$1,750Feb 26, 2009--
01001B1926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious14$0$0Feb 26, 2009--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)2 citations · $2,313
1926.1053Ladders (Construction)2 citations · $7,200
1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $563

Industry comparison

Violations per inspection
This employer1.4
Industry average2.1
Penalties per inspection
This employer$2,915
Industry average$2,530

Specialty Trade Contractors, 552,053 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: plumbing, heating, and air-conditioning contractors reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.2%; NAICS 23822 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source