RESOURCE ENGINEERING & MANUFACTURING CO
1801 N 170TH E AVE, TULSA, OK 74116
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 13, 1986#100279009Mar 13, 1986Referral (C) · Complete scope, Health#100279009$4005 viol.5 violations$400 in penalties
Inspection #100279009
Dates
- Opened
- Mar 13, 1986
- Closing Conference Date
- Mar 19, 1986
- Closed
- Oct 1, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 55
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 other-than-serious
- Initial Penalties
- $800
- Penalties on Record
- $400
- Site Address
- 1801 N 170th E Ave, Tulsa, OK 74116
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling16 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 6 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 6 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 6 | 0 - 0.0209 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 6 | 0 - 0.0372 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 6 | 0 - 0.009 | mg/m³ |
| Copper Fume (as Cu) | 6 | 0 - 0.0204 | mg/m³ |
| Iron Oxide Fume | 6 | 0 - 1.7877 | mg/m³ |
| Lead, Inorganic (as Pb) | 6 | 0 - 0.0293 | mg/m³ |
| Manganese Fume (as Mn) | 6 | 0 - 0.2177 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 6 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 6 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 6 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 2 | 0.438 - 4.044 | mg/m³ |
| Silica, Crystalline Quartz (Respirable Fraction) | 2 | 21 - 34 | % |
| Vanadium fume (as V2O5) | 6 | 0 | mg/m³ |
| Zinc Oxide Fume | 6 | 0 - 0.0298 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.94 Ventilation OSHA citation code: 19100094 A02 II | Serious | 2 | 1 | $400 | $200 | May 14, 1986 | - | - |
| 01001B | 1910.94 Ventilation OSHA citation code: 19100094 A05 IV | Serious | 2 | 1 | $0 | $0 | May 29, 1986 | - | - |
| 01002A | 1910.94 Ventilation OSHA citation code: 19100094 A05 IIB | Serious | 1 | 1 | $400 | $200 | May 14, 1986 | - | - |
| 01002B | 1910.94 Ventilation OSHA citation code: 19100094 A05 IIIB | Serious | 1 | 1 | $0 | $0 | May 14, 1986 | - | - |
| 02001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Other | 4 | 11 | $0 | $0 | Jul 9, 1986 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.