Skip to content
SafetyRecord logoSafetyRecord
REZTEC MANUFACTURING, INC.
$5,325
penalties
20
viol.
1
insp.

REZTEC MANUFACTURING, INC.

450 E 32ND ST, FREMONT, NE 68025NAICS 326191 Plastics Plumbing Fixture Manufacturing

Inspections
1
Apr 2003 to Apr 2003 · 0 safety, 1 health
Violations
20
across 1 inspection
Penalties on record
$5,325
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 2, 2003Complaint (B) · Partial scope, Health#306015967$5,32520 viol.

Inspection #306015967

Dates

Opened
Apr 2, 2003
Closing Conference Date
Apr 8, 2003
Closed
Jul 23, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 complaint

Violations and Penalties

Total Violations
20
Violation Types
19 serious, 1 other-than-serious
Initial Penalties
$10,650
Penalties on Record
$5,325
Site Address
450 E 32nd St, Fremont, NE 68025
Industry
326191 Plastics Plumbing Fixture Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC22.0941 - 8.6553mg/m³
Methyl Methacrylate60 - 0.4402885ppm
Particulates not otherwise regulated (Respirable Fraction)22.0941 - 8.6553mg/m³
Sample WeightQC20.595 - 4.203mg
Styrene621.9339104 - 53.0517883ppm

Violations

Violation list (20 of 20 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious22$1,050$525Dec 31, 2003--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious58$750$375Aug 30, 2003--
010031910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01 I
Serious58$600$300Aug 30, 2003--
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious15$1,050$525Aug 15, 2003--
01004B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious11$0$0May 31, 2004--
01004C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Mar 31, 2004--
010051910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious55$600$300Mar 31, 2004--
010061910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious18$600$300Dec 31, 2003--
010071910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious28$600$300Dec 31, 2003--
010081910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious33$600$300Dec 31, 2003--
010091910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 D01
Serious13$750$375Aug 30, 2003--
010101910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious18$600$300Aug 30, 2003--
010111910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious32$1,050$525Aug 30, 2003--
010121910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious28$600$300Jul 31, 2004--
010131910.1052
Methylene Chloride
OSHA citation code: 19101052 D01 I
Serious12$600$300Jul 14, 2003--
01014A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious15$600$300Dec 31, 2003--
01014B1910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Serious55$0$0Dec 31, 2003--
01015A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious75$600$300Dec 31, 2003--
01015B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious75$0$0Dec 31, 2003--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Other38$0$0Aug 30, 2003--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication4 citations · $600
1910.1000Air Contaminants2 citations · $0
1910.134Respiratory Protection2 citations · $825

Chemical exposure sampling

Samples
18
Substances
5
Inspections
1

Industry comparison

Violations per inspection
This employer20.0
Industry average2.8
Penalties per inspection
This employer$5,325
Industry average$3,078

Plastics and Rubber Products Manufacturing, 12,555 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: plastics plumbing fixture manufacturing reported 3.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.1%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in FREMONT, NE

All employers in FREMONT →