ST. LOUIS PRECISION CASTING CO.
10922 GRAVOIS INDUSTRIAL CT., ST. LOUIS, MO 63128
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 17, 1998#113882831Mar 17, 1998Planned (H) · Partial scope, Health#113882831$6003 viol.3 violations$600 in penalties
Inspection #113882831
Dates
- Opened
- Mar 17, 1998
- Closing Conference Date
- May 20, 1998
- Closed
- May 17, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 13
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $600
- Penalties on Record
- $600
- Site Address
- 10922 Gravois Industrial Ct., St. Louis, MO 63128
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 2 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 2 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 2 | 0.0058 - 0.0132 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 2 | 0 | mg/m³ |
| Copper Fume (as Cu) | 2 | 0.0129 - 0.0301 | mg/m³ |
| Gravimetric DeterminationQC | 7 | 0 - 5.726 | mg/m³ |
| Iron Oxide Fume | 2 | 0.7482 - 1.5997 | mg/m³ |
| Lead, Inorganic (as Pb) | 2 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 2 | 0.0377 - 0.0441 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 2 | 0.0367 - 0.1612 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 2 | 0.0016 - 0.0051 | mg/m³ |
| Sample WeightQC | 7 | 0 - 5.016 | mg |
| Silica, Crystalline Quartz (Respirable Fraction) | 5 | 1 - 7 | % |
| Vanadium fume (as V2O5) | 2 | 0.0026 - 0.0047 | mg/m³ |
| Zinc Oxide Fume | 2 | 0.0178 - 0.0226 | mg/m³ |
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.1000 Air Contaminants OSHA citation code: 19101000 C | Serious | 1 | 1 | $600 | $600 | May 28, 1999 | - | - |
| 01001B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 1 | $0 | $0 | May 28, 1999 | - | - |
| 01001C | 1910.141 Sanitation OSHA citation code: 19100141 G02 | Serious | 1 | 1 | $0 | $0 | Jun 16, 1998 | - | - |
Jun 19, 1992#106696669Jun 19, 1992Planned (H) · Complete scope, Health#106696669$1,72517 viol.17 violations$1,725 in penalties
Inspection #106696669
Dates
- Opened
- Jun 19, 1992
- Closing Conference Date
- Aug 26, 1992
- Closed
- Nov 2, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 13
Violations and Penalties
- Total Violations
- 17
- Violation Types
- 10 serious, 7 other-than-serious
- Initial Penalties
- $3,450
- Penalties on Record
- $1,725
- Site Address
- 10922 Gravois Industrial Ct., St. Louis, MO 63128
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling2 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Formaldehyde | 2 | 0 - 0.081 | ppm |
| Silica, Crystalline Quartz (Respirable Fraction) | 4 | 0.44 - 27 | % |
Violations
Violation list (16 of 17 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 1 | $300 | $100 | Sep 22, 1992 | - | - |
| 01002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 III | Serious | 1 | 1 | $300 | $100 | Oct 23, 1992 | - | - |
| 01003 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Serious | 2 | 1 | $525 | $200 | Nov 2, 1992 | - | - |
| 01004A | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 1 | 5 | $750 | $750 | Oct 23, 1992 | - | - |
| 01004B | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 1 | 1 | $0 | $0 | Jun 30, 1993 | - | - |
| 01004C | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 1 | $0 | $0 | Sep 30, 1993 | - | - |
| 01005 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 I | Serious | 1 | 1 | $300 | $100 | Sep 14, 1992 | - | - |
| 01006A | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 A02 | Serious | 1 | 2 | $525 | $375 | Sep 14, 1992 | - | - |
| 01006B | 1910.307 Electrical - Hazardous (Classified) Locations OSHA citation code: 19100307 B | Serious | 1 | 2 | $0 | $0 | Sep 18, 1992 | - | - |
| 01007 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 3 | $300 | $100 | Sep 22, 1992 | - | - |
| 02001 | 1904.2 Partial Exemption for Establishments in Certain Industries OSHA citation code: 19040002 A | Other | 1 | 1 | $150 | $0 | Sep 14, 1992 | - | - |
| 02002 | 1910.20 Access to Employee Exposure and Medical Records OSHA citation code: 19100020 G01 III | Other | 1 | 10 | $0 | $0 | Sep 22, 1992 | - | - |
| 02003 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 2 | 10 | $150 | $0 | Sep 22, 1992 | - | - |
| 02004 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 L01 | Other | 1 | 3 | $0 | $0 | Sep 14, 1992 | - | - |
| 02005 | 1910.141 Sanitation OSHA citation code: 19100141 G02 | Other | 1 | 1 | $150 | $0 | Sep 22, 1992 | - | - |
| 02006 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Other | 1 | 10 | $0 | $0 | Sep 22, 1992 | - | - |
Showing the 16 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 7, 1987#103124491Apr 7, 1987Planned (H) · No Inspection scope, Safety#103124491$00 viol.0 violations$0 in penalties
Inspection #103124491
Dates
- Opened
- Apr 7, 1987
- Closing Conference Date
- Apr 7, 1987
- Closed
- Apr 20, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Not recorded
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 10922 Gravois Industrial Court, St. Louis, MO 63128
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1987 to 1998. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.