Skip to content
SafetyRecord logoSafetyRecord
STAHL, A SCOTT FETZER COMPANY
$3,475
penalties
16
viol.
2
insp.

STAHL, A SCOTT FETZER COMPANY

92 WALDRON DRIVE, Durant, OK 74701

Inspections
2
Jun 1998 to Jul 1998 · 1 safety, 1 health
Violations
16
across 2 inspections
Penalties on record
$3,475
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 8, 1998Referral (C) · Partial scope, Safety#301875233$2504 viol.

Inspection #301875233

Dates

Opened
Jul 8, 1998
Closing Conference Date
Jul 8, 1998
Closed
Mar 31, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
86
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$500
Penalties on Record
$250
Site Address
92 Waldron Drive, Durant, OK 74701
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02I B
Serious11$500$250Sep 23, 1998--
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other12$0$0Sep 23, 1998--
020021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C06I
Other15$0$0Oct 1, 1998--
020031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Other714$0$0Sep 22, 1998--
Jun 9, 1998Complaint (B) · Partial scope, Health#301877007$3,22512 viol.

Inspection #301877007

Dates

Opened
Jun 9, 1998
Closing Conference Date
Jun 10, 1998
Closed
Jan 5, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
86
Related Activity
1 complaint

Violations and Penalties

Total Violations
12
Violation Types
8 serious, 4 other-than-serious
Initial Penalties
$9,000
Penalties on Record
$3,225
Site Address
92 Waldron Drive, Durant, OK 74701
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling7 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone21.2484 - 1.6779ppm
Ethyl Benzene42.5687 - 21.1366ppm
Hexone20.6568 - 0.8528ppm
n-Propyl Alcohol20ppm
Stoddard Solvent281.673 - 237.5744mg/m³
Toluene41.047 - 1.6772ppm
Xylene49.9418 - 81.4073ppm

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious25$4,500$2,000Sep 30, 1998--
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious25$0$0Oct 21, 1998--
010021910.132
General requirements
OSHA citation code: 19100132 A
Serious25$1,350$450Sep 1, 1998--
01003A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious14$1,350$675Sep 30, 1998--
01003B1910.134
Respiratory Protection
OSHA citation code: 19100134 E02
Serious12$0$0Sep 30, 1998--
01003C1910.134
Respiratory Protection
OSHA citation code: 19100134 E04
Serious14$0$0Sep 30, 1998--
01003D1910.134
Respiratory Protection
OSHA citation code: 19100134 E05
Serious14$0$0Sep 30, 1998--
01004A1910.1025
Lead
OSHA citation code: 19101025 D02
Other14$1,800$0Sep 30, 1998--
01004B1910.1025
Lead
OSHA citation code: 19101025 N04 I
Other14$0$0Sep 30, 1998--
01005B1910.1200
Hazard Communication
OSHA citation code: 19101200 E04
Serious186$0$100Sep 15, 1998--
020011910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Other12$0$0Sep 7, 1998--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other186$0$0Sep 30, 1998--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection4 citations · $675
1910.1025Lead2 citations · $0
1910.95Occupational Noise Exposure2 citations · $2,000

Chemical exposure sampling

Samples
20
Substances
7
Inspections
1

Other inspected employers in Durant, OK

All employers in Durant →