STEEL STRUCTURES OF OHIO, LLC
$70,599
penalties
39
viol.
3
insp.

STEEL STRUCTURES OF OHIO, LLC

1324 FIRESTONE PARKWAY, AKRON, OH 44301NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
3
Jun 2009 to Apr 2011 · 1 safety, 2 health
Violations
39
across 3 inspections
Penalties on record
$70,599
latest amounts in DOL records
By classification
Serious 27Willful 0Repeat 7Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 13, 2011Complaint (B) · Partial scope, Health#315443689$36,76113 viol.

Inspection #315443689

Dates

Opened
Apr 13, 2011
Closing Conference Date
Aug 9, 2011
Contested
Oct 25, 2011
Final Order
Jul 28, 2012
Closed
Oct 30, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
67
Related Activity
1 complaint

Violations and Penalties

Total Violations
13
Violation Types
4 serious, 7 repeat, 2 other-than-serious
Initial Penalties
$48,300
Penalties on Record
$36,761
Site Address
1324 Firestone Parkway, Akron, OH 44301
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone40ppm
Antimony and Compounds (as Sb)50mg/m³
Beryllium and Beryllium Compounds (as Be)50mg/m³
Cadmium50mg/m³
Chromium, Metal and Insoluble Salts50mg/m³
Cobalt, Metal, Dust and Fume (as Co)50mg/m³
Copper Fume (as Cu)50 - 0.0305025mg/m³
Ethyl Benzene42.042863 - 4.603006ppm
Iron Oxide Fume50.3379254 - 2.7360809mg/m³
Lead, Inorganic (as Pb)50mg/m³
Manganese Fume (as Mn)50.008097 - 0.173493mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)50mg/m³
Nickel, Metal and Insoluble compounds (as Ni)50mg/m³
Vanadium fume (as V2O5)50mg/m³
Xylene410.98171 - 24.86401ppm
Zinc Oxide Fume50mg/m³

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious12$3,500$2,664Dec 13, 2011Oct 25, 2011Jul 28, 2012
010021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious12$3,500$2,664Oct 29, 2011Oct 25, 2011Jul 28, 2012
010031910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious32$2,100$1,598Oct 29, 2011Oct 25, 2011Jul 28, 2012
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IX
Serious12$2,800$2,131Oct 19, 2011Oct 25, 2011Jul 28, 2012
020011910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Repeat12$8,400$6,393Oct 29, 2011Oct 25, 2011Jul 28, 2012
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Repeat12$8,400$6,393Oct 29, 2011Oct 25, 2011Jul 28, 2012
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Repeat12$8,400$6,393Oct 29, 2011Oct 25, 2011Jul 28, 2012
02004A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Repeat11$4,200$3,197Oct 29, 2011Oct 25, 2011Jul 28, 2012
02004B1910.134
Respiratory Protection
OSHA citation code: 19100134 F01
Repeat11$0$0Oct 29, 2011Oct 25, 2011Jul 28, 2012
02004C1910.134
Respiratory Protection
OSHA citation code: 19100134 K01
Repeat11$0$0Oct 29, 2011Oct 25, 2011Jul 28, 2012
020051910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Repeat12$7,000$5,328Oct 29, 2011Oct 25, 2011Jul 28, 2012
030011910.133
Eye and Face Protection
OSHA citation code: 19100133 A03
Other11$0$0Oct 19, 2011Oct 25, 2011Jul 28, 2012
030021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other167$0$0Oct 19, 2011Oct 25, 2011Jul 28, 2012
Apr 13, 2011Complaint (B) · Partial scope, Safety#315443663$28,23811 viol.

Inspection #315443663

Dates

Opened
Apr 13, 2011
Closing Conference Date
May 23, 2011
Contested
Oct 25, 2011
Final Order
Jul 28, 2012
Closed
Oct 30, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
67
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
9 serious, 2 other-than-serious
Initial Penalties
$86,100
Penalties on Record
$28,238
Site Address
1324 Firestone Parkway, Akron, OH 44301
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Serious11$2,800$2,131Oct 28, 2011Oct 25, 2011Jul 28, 2012
01001B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious11$0$0Oct 28, 2011Oct 25, 2011Jul 28, 2012
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 D02
Serious11$2,800$2,131Oct 28, 2011Oct 25, 2011Jul 28, 2012
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious12$4,900$3,730Oct 28, 2011Oct 25, 2011Jul 28, 2012
020011910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02
Serious13$49,000$5,328Oct 28, 2011Oct 25, 2011Jul 28, 2012
03001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 IID
Other12$7,000$0Nov 13, 2011Oct 25, 2011Jul 28, 2012
03001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 II
Other11$0$0Oct 28, 2011Oct 25, 2011Jul 28, 2012
030021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04
Serious12$5,600$4,262Nov 13, 2011Oct 25, 2011Jul 28, 2012
030031910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Serious13$4,200$3,197Oct 28, 2011Oct 25, 2011Jul 28, 2012
03004A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$9,800$7,459Oct 28, 2011Oct 25, 2011Jul 28, 2012
03004B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$0$0Oct 28, 2011Oct 25, 2011Jul 28, 2012
Jun 11, 2009Complaint (B) · Partial scope, Health#313455446$5,60015 viol.

Inspection #313455446

Dates

Opened
Jun 11, 2009
Closing Conference Date
Aug 17, 2009
Closed
Feb 3, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46
Related Activity
1 complaint

Violations and Penalties

Total Violations
15
Violation Types
14 serious, 1 other-than-serious
Initial Penalties
$9,500
Penalties on Record
$5,600
Site Address
1324 Firestone Parkway, Akron, OH 44301
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (15 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.25
Stairways
OSHA citation code: 19100025 D01 X
Serious112$750$450Nov 18, 2009--
01002A1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Serious14$1,750$1,050Dec 4, 2009--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious14$0$0Dec 1, 2009--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious15$1,000$600Nov 26, 2009--
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious18$750$450Feb 1, 2010--
01004B1910.134
Respiratory Protection
OSHA citation code: 19100134 F01
Serious18$0$0Feb 1, 2010--
01004C1910.134
Respiratory Protection
OSHA citation code: 19100134 K01
Serious18$0$0Feb 1, 2010--
01005A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious15$1,250$700Dec 1, 2009--
01005B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious15$0$0Dec 1, 2009--
01005C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious15$0$0Dec 1, 2009--
010061910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Serious32$750$450Nov 18, 2009--
010071910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Serious14$750$450Dec 1, 2009--
010081910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02
Serious125$1,250$750Jan 15, 2010--
010091910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious510$1,250$700Dec 1, 2009--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other130$0$0Feb 1, 2010--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection7 citations · $5,245
1910.107Spray Finishing Using Flammable and Combustible Materials6 citations · $17,648
1910.147Control of Hazardous Energy (Lockout/Tagout)5 citations · $700

Chemical exposure sampling

Samples
77
Substances
16
Inspections
1

Industry comparison

Violations per inspection
This employer13.0
Industry average3.3
Penalties per inspection
This employer$23,533
Industry average$2,287

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: fabricated structural metal manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in AKRON, OH

All employers in AKRON →