Skip to content
SafetyRecord logoSafetyRecord
STERLING HANDLING EQUIPMENT CO.
$4,400
penalties
19
viol.
3
insp.

STERLING HANDLING EQUIPMENT CO.

2300 WEST FLORIST AVENUE, MILWAUKEE, WI 53209

Inspections
3
Mar 1988 to Aug 2007 · 2 safety, 1 health
Violations
19
across 3 inspections
Penalties on record
$4,400
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 28, 2007Referral (C) · Partial scope, Health#309361210$05 viol.

Inspection #309361210

Dates

Opened
Aug 28, 2007
Closing Conference Date
Oct 12, 2007
Closed
Nov 5, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2300 West Florist Avenue, Milwaukee, WI 53209
Industry
332999 All Other Miscellaneous Fabricated Metal Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Carbon Black21.8 - 20mg/m³
Ethyl Benzene20 - 22.833848ppm
Gravimetric DeterminationQC20.5364 - 29.8093mg/m³
Sample WeightQC20.059 - 3.361mg
Xylene20 - 95.381105ppm

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C07
Other11$0$0Oct 31, 2007--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Other11$0$0Nov 15, 2007--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G03
Other11$0$0Oct 24, 2007--
010041910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other11$0$0Nov 10, 2007--
010051910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Other11$0$0Oct 23, 2007--
Aug 21, 2007Complaint (B) · Partial scope, Safety#309361160$4,40014 viol.

Inspection #309361160

Dates

Opened
Aug 21, 2007
Closing Conference Date
Dec 18, 2007
Closed
Dec 18, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16
Related Activity
1 complaint

Violations and Penalties

Total Violations
14
Violation Types
11 serious, 3 other-than-serious
Initial Penalties
$4,200
Penalties on Record
$4,400
Site Address
2300 West Florist Avenue, Milwaukee, WI 53209
Industry
336999 All Other Transportation Equipment Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious13$1,500$800Jan 16, 2008--
01001B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious13$0$0Jan 16, 2008--
010081910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 I
Other14$750$0Feb 15, 2008--
010091910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious14$750$500Feb 27, 2008--
01011A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious23$750$400Jan 16, 2008--
01011B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious13$0$0Jan 16, 2008--
01011C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious13$0$0Jan 11, 2008--
010121910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Serious23$450$200Jan 9, 2008--
01013A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious33$0$800Feb 27, 2008--
01013B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious33$0$0Feb 27, 2008--
01014A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B06 II
Serious14$0$1,500Jan 9, 2008--
01014B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C03 VIII
Serious14$0$0Jan 9, 2008--
02001A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Other13$0$200Jan 16, 2008--
02001B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Other13$0$0Jan 16, 2008--
Mar 22, 1988Planned (H) · No Inspection scope, Safety#103466652$00 viol.

Inspection #103466652

Dates

Opened
Mar 22, 1988
Closing Conference Date
Mar 22, 1988
Closed
Mar 22, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2300 West Florist Avenue, Milwaukee, WI 53209
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses4 citations · $2,000
1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $0
1910.219Mechanical Power-Transmission Apparatus3 citations · $400

Chemical exposure sampling

Samples
10
Substances
5
Inspections
1

Other inspected employers in MILWAUKEE, WI