Skip to content
SafetyRecord logoSafetyRecord
STERN METALS CO. INC./I. STERN DIVISION
$1,800
penalties
9
viol.
1
insp.

STERN METALS CO. INC./I. STERN DIVISION

320 WASHINGTON STREET, Mount Vernon, NY 10553

Inspections
1
Jan 1989 to Jan 1989 · 0 safety, 1 health
Violations
9
across 1 inspection
Penalties on record
$1,800
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 20, 1989Planned (H) · Complete scope, Health#107647059$1,8009 viol.

Inspection #107647059

Dates

Opened
Jan 20, 1989
Closing Conference Date
May 18, 1989
Closed
Dec 18, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
50

Violations and Penalties

Total Violations
9
Violation Types
7 serious, 2 other-than-serious
Initial Penalties
$1,800
Penalties on Record
$1,800
Site Address
320 Washington Street, Mount Vernon, NY 10553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Ammonia20
Antimony and Compounds (as Sb)70mg/m³
Beryllium and Beryllium Compounds (as Be)70mg/m³
Cadmium Fume (as Cd)70 - 0.0095mg/m³
Chromium, Metal and Insoluble Salts70mg/m³
Cobalt, Metal, Dust and Fume (as Co)70mg/m³
Copper Fume (as Cu)70mg/m³
Iron Oxide Fume70mg/m³
Lead, Inorganic (as Pb)70mg/m³
Manganese Fume (as Mn)70 - 0.0034mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)50mg/m³
Nickel, Metal and Insoluble compounds (as Ni)70 - 0.0244mg/m³
Particulates not otherwise regulated (Respirable Fraction)50mg/m³
Particulates not otherwise regulated (Total Dust)30mg/m³
Sulfur Dioxide10.87ppm
Vanadium fume (as V2O5)70mg/m³
Zinc Oxide Fume70 - 0.0447mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.252
General requirements
OSHA citation code: 19100252 A02 IIB
Serious42$360$360Jun 12, 1989--
010021910.252
General requirements
OSHA citation code: 19100252 A02 IIC
Serious12$360$360Jun 12, 1989--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious41$360$360Jun 12, 1989--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious41$0$0Jun 12, 1989--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious110$420$420Jun 22, 1989--
020011910.252
General requirements
OSHA citation code: 19100252 A02 IID
Other110$0$0Jun 12, 1989--
03001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$300$300Aug 20, 1989--
03001B1910.134
Respiratory Protection
OSHA citation code: 19100134 C
Serious11$0$0Aug 20, 1989--
040011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other11$0$0Nov 23, 1989--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.252General requirements3 citations · $720
1910.1200Hazard Communication3 citations · $780
1910.134Respiratory Protection2 citations · $300

Chemical exposure sampling

Samples
100
Substances
17
Inspections
1

Other inspected employers in Mount Vernon, NY

All employers in Mount Vernon →