Skip to content
SafetyRecord logoSafetyRecord
STOUT ROOFING, INC.
$4,725
penalties
33
viol.
22
insp.

STOUT ROOFING, INC.

9480 W. TROPICAL PARKWAY, Las Vegas, NV 89149NAICS 238160 Roofing Contractors

Inspections
22
May 2001 to Apr 2013 · 20 safety, 2 health
Violations
33
across 22 inspections
Penalties on record
$4,725
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 0Other 23

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 3, 2004Referral (C) · No Inspection scope, Safety#307585059$00 viol.

Inspection #307585059

Dates

Opened
May 3, 2004
Closing Conference Date
May 3, 2004
Closed
May 3, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
Not recorded
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Craig/Lamb Blvd, Las Vegas, NV 89115
Industry
238160 Roofing Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Apr 20, 2004Referral (C) · No Inspection scope, Safety#307584276$00 viol.

Inspection #307584276

Dates

Opened
Apr 20, 2004
Closing Conference Date
Not recorded
Closed
Apr 20, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Fire Mesa/Trinity Peak, Las Vegas, NV 89148
Industry
238160 Roofing Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Oct 29, 2003Planned (H) · Complete scope, Safety#307111815$02 viol.

Inspection #307111815

Dates

Opened
Oct 29, 2003
Closing Conference Date
Dec 10, 2003
Closed
Dec 24, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3100 E. Patrick Lane, Las Vegas, NV 89120
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other17$0$0Dec 15, 2003--
01001B1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other17$0$0Dec 19, 2003--
Oct 29, 2003Referral (C) · Partial scope, Safety#307111658$7503 viol.

Inspection #307111658

Dates

Opened
Oct 29, 2003
Closing Conference Date
Nov 3, 2003
Closed
Jan 13, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,250
Penalties on Record
$750
Site Address
4200 Flossmoor St., Las Vegas, NV 89115
Industry
238160 Roofing Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.102
Eye and face protection
OSHA citation code: 19260102 A01
Serious11$625$375Nov 17, 2003--
01002A1926.307
Mechanical Power-Transmission Apparatus
OSHA citation code: 19260307 C02 I
Serious11$625$375Nov 17, 2003--
01002B1926.307
Mechanical Power-Transmission Apparatus
OSHA citation code: 19260307 C03
Serious11$0$0Nov 17, 2003--
Oct 16, 2002Planned (H) · Complete scope, Safety#305702631$6752 viol.

Inspection #305702631

Dates

Opened
Oct 16, 2002
Closing Conference Date
Nov 6, 2002
Closed
Jan 22, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$1,125
Penalties on Record
$675
Site Address
4195 S. Fort Apache Road, Las Vegas, NV 89147
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B04
Serious16$1,125$675Nov 18, 2002--
02001618056501Other215$0$0Nov 26, 2002--
Oct 16, 2002Planned (H) · Complete scope, Health#305702326$00 viol.

Inspection #305702326

Dates

Opened
Oct 16, 2002
Closing Conference Date
Nov 6, 2002
Closed
Nov 6, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4195 S. Fort Apache Road, Las Vegas, NV 89147
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 19, 2002Planned (H) · Complete scope, Safety#305457269$00 viol.

Inspection #305457269

Dates

Opened
Jun 19, 2002
Closing Conference Date
Jun 26, 2002
Closed
Jun 26, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4851 E. Lake Mead, Las Vegas, NV 89115
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Dec 12, 2001Planned (H) · Complete scope, Safety#305000382$00 viol.

Inspection #305000382

Dates

Opened
Dec 12, 2001
Closing Conference Date
Dec 14, 2001
Closed
Dec 14, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4105 N. Lamb Blvd, Las Vegas, NV 89115
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 27, 2001Planned (H) · Complete scope, Safety#304642051$01 viol.

Inspection #304642051

Dates

Opened
Jun 27, 2001
Closing Conference Date
Jul 26, 2001
Closed
Aug 1, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4750 S. Decatur, Las Vegas, NV 89103
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.307
Mechanical Power-Transmission Apparatus
OSHA citation code: 19260307 I02
Other11$0$0Jul 26, 2001--
Jun 5, 2001Planned (H) · Complete scope, Safety#304427107$00 viol.

Inspection #304427107

Dates

Opened
Jun 5, 2001
Closing Conference Date
Jun 14, 2001
Closed
Jun 14, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4700 Conough Lane, Las Vegas, NV 89129
Industry
238160 Roofing Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 11 to 20 of 22, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

6180540024 citations · $0
1926.307Mechanical Power-Transmission Apparatus3 citations · $375
1904.32Annual Summary3 citations · $0

Industry comparison

Violations per inspection
This employer1.5
Industry average2.1
Penalties per inspection
This employer$215
Industry average$2,531

Specialty Trade Contractors, 552,116 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: roofing contractors reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.7%; NAICS 23816 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Las Vegas, NV

All employers in Las Vegas →