Skip to content
SafetyRecord logoSafetyRecord
STRAN BUILDINGS, DIV. OF AMCA INTERNATIONAL
$1,800
penalties
31
viol.
4
insp.

STRAN BUILDINGS, DIV. OF AMCA INTERNATIONAL

1202 INDUSTRIAL DRIVE, Van Wert, OH 45891NAICS 332311 Prefabricated Metal Building and Component Manufacturing

Inspections
4
Sep 1986 to Apr 1989 · 2 safety, 2 health
Violations
31
across 4 inspections
Penalties on record
$1,800
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 24

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 26, 1989Complaint (B) · Partial scope, Health#106273337$1,0504 viol.

Inspection #106273337

Dates

Opened
Apr 26, 1989
Closing Conference Date
Apr 26, 1989
Closed
Jun 9, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
270
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$1,050
Penalties on Record
$1,050
Site Address
1202 Industrial Drive, Van Wert, OH 45891
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious12$350$350May 30, 1989--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$350$350May 30, 1989--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious12$350$350Jun 23, 1989--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious11$0$0Jun 6, 1989--
Nov 18, 1988Complaint (B) · Partial scope, Safety#103061008$01 viol.

Inspection #103061008

Dates

Opened
Nov 18, 1988
Closing Conference Date
Nov 18, 1988
Closed
Feb 21, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
235
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1202 Industrial Drive, Van Wert, OH 45891
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other11$0$0Dec 19, 1988--
Sep 26, 1986Referral (C) · Complete scope, Health#101655223$02 viol.

Inspection #101655223

Dates

Opened
Sep 26, 1986
Closing Conference Date
Sep 30, 1987
Closed
Jul 7, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
180
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1202 Industrial Drive, Van Wert, OH 45891
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20 - 0.0103mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Iron Oxide Fume20 - 0.323mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20 - 0.0016mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)20mg/m³
Petroleum Distillates (Naphtha) (Rubber Solvent)50mg/m³
Toluene53.7 - 30.6ppm
Vanadium fume (as V2O5)20mg/m³
Xylene58.7 - 39.4ppm
Zinc Oxide Fume20 - 0.0159mg/m³

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 F04 II
Other14$0$0Nov 14, 1986--
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other533$0$0Feb 23, 1987--
Sep 9, 1986Planned (H) · Complete scope, Safety#101654523$75024 viol.

Inspection #101654523

Dates

Opened
Sep 9, 1986
Closing Conference Date
Sep 15, 1986
Closed
Jan 6, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
180

Violations and Penalties

Total Violations
24
Violation Types
3 serious, 21 other-than-serious
Initial Penalties
$750
Penalties on Record
$750
Site Address
1202 Industrial Drive, Van Wert, OH 45891
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 24 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious13$70$70Oct 23, 1986--
010021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious214$400$400Oct 23, 1986--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 IV
Serious54$140$140Oct 23, 1986--
020011904.2
OSHA citation code: 19040002 A
Other99$70$70Nov 3, 1986--
020021904.4Other1180$70$70Nov 3, 1986--
020031910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Other413$0$0Oct 16, 1986--
020041910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02 IV
Other1320$0$0Nov 3, 1986--
020051910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 N04 I
Other1320$0$0Oct 16, 1986--
020061910.184
Slings
OSHA citation code: 19100184 E01
Other2020$0$0Nov 18, 1986--
020071910.184
Slings
OSHA citation code: 19100184 E03 II
Other2020$0$0Nov 3, 1986--
020081910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other12$0$0Oct 16, 1986--
020091910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other12$0$0Oct 16, 1986--

Showing the 12 violations listed first by citation identifier. This inspection has 24 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication6 citations · $350
1910.217Mechanical Power Presses6 citations · $140
1910.179Overhead and Gantry Cranes3 citations · $0

Chemical exposure sampling

Samples
42
Substances
17
Inspections
1

Industry comparison

Violations per inspection
This employer7.8
Industry average3.3
Penalties per inspection
This employer$450
Industry average$2,302

Fabricated Metal Product Manufacturing, 45,931 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Van Wert, OH

All employers in Van Wert →