Skip to content
SafetyRecord logoSafetyRecord
STS STEEL INC
$17,518
penalties
61
viol.
11
insp.

STS STEEL INC

301 NOTT STREET, BLDG. 304, SCHENECTADY, NY 12305

Inspections
11
Jul 1993 to Mar 2024 · 5 safety, 6 health
Violations
61
across 11 inspections
Penalties on record
$17,518
latest amounts in DOL records
By classification
Serious 40Willful 0Repeat 0Other 21

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 18, 2024Referral (C) · Partial scope, Safety#347351892$7,3401 viol.

Inspection #347351892

Dates

Opened
Mar 18, 2024
Closing Conference Date
Mar 18, 2024
Final Order
Sep 18, 2024
Closed
Nov 12, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
58
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$11,292
Penalties on Record
$7,340
Site Address
10 Rush St., Schenectady, NY 12305
Industry
332312 Fabricated Structural Metal Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 N03 III B
Other12$11,292$7,340Sep 6, 2024-Sep 18, 2024
May 5, 2023Complaint (B) · Partial scope, Health#346681596$00 viol.

Inspection #346681596

Dates

Opened
May 5, 2023
Closing Conference Date
May 5, 2023
Closed
Aug 23, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
47
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
10 Rush St., Schenectady, NY 12305
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Nov 19, 2021Complaint (B) · Partial scope, Health#345647754$00 viol.

Inspection #345647754

Dates

Opened
Nov 19, 2021
Closing Conference Date
Nov 19, 2021
Closed
Jan 20, 2022

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
54
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
10 Rush St., Schenectady, NY 12305
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Mar 12, 2013Complaint (B) · Partial scope, Health#338948045$1,4705 viol.

Inspection #338948045

Dates

Opened
Mar 12, 2013
Closing Conference Date
Mar 12, 2013
Final Order
May 15, 2013
Closed
Jun 3, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
55
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
4 serious, 1 other-than-serious
Initial Penalties
$4,200
Penalties on Record
$1,470
Site Address
301 Nott Street, Bldg. 304, Schenectady, NY 12305
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01003A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E01
Serious142$2,100$1,470May 28, 2013-May 15, 2013
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious142$0$0May 28, 2013-May 15, 2013
01003C1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious142$0$0May 28, 2013-May 15, 2013
01003D1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Serious142$2,100$0May 28, 2013-May 15, 2013
020011910.134
Respiratory Protection
OSHA citation code: 19100134 D03 III B 2
Other11$0$0Jun 12, 2013-May 15, 2013
Nov 17, 2009Planned (H) · Complete scope, Safety#313755514$00 viol.

Inspection #313755514

Dates

Opened
Nov 17, 2009
Closing Conference Date
Nov 17, 2009
Closed
Dec 18, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
65

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
301 Nott Street, Bldg. 304, Schenectady, NY 12305
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Mar 11, 2009Planned (H) · Complete scope, Health#311977359$8583 viol.

Inspection #311977359

Dates

Opened
Mar 11, 2009
Closing Conference Date
Apr 23, 2009
Closed
Sep 3, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
65

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$2,225
Penalties on Record
$858
Site Address
301 Nott Street, Building 304, Schenectady, NY 12305
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling5 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Benzene30ppm
Methyl (n-amyl) ketone314.72581 - 51.509514ppm
n-Butyl Acetate30.925321 - 2.987183ppm
Toluene312.413235 - 22.393195ppm
Xylene31.643582 - 4.453407ppm

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious21$1,225$858Jul 7, 2009--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious33$0$0Jul 7, 2009--
020011904.29
Forms
OSHA citation code: 19040029 B01
Other18$1,000$0Jul 7, 2009--
Jun 5, 2002Planned (H) · Partial scope, Safety#304467384$3382 viol.

Inspection #304467384

Dates

Opened
Jun 5, 2002
Closing Conference Date
Jun 5, 2002
Closed
Jul 18, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$675
Penalties on Record
$338
Site Address
301 Nott Street, Bldg. 304, Schenectady, NY 12305
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$675$338Jun 20, 2002--
020011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other65$0$0Jun 25, 2002--
Mar 20, 2001Follow-Up (F) · Partial scope, Health#303375430$1203 viol.

Inspection #303375430

Dates

Opened
Mar 20, 2001
Closing Conference Date
Jul 6, 2001
Closed
Nov 14, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
56

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
301 Nott Street, Bldg. 304, Schenectady, NY 12305
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20 - 0.0041738mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium20 - 0.0013657mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.0030446mg/m³
Gravimetric DeterminationQC55.5803 - 723.4925mg/m³
Iron Oxide Fume20.2376414 - 0.3787047mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20.0223884 - 0.0282663mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20 - 0.0023825mg/m³
Particulates not otherwise regulated (Total Dust)2191.5223 - 723.4925mg/m³
Sample WeightQC60 - 32.396mg
Silica, Crystalline Quartz (Respirable Fraction)40 - 3
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume2120 - 280mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
020011910.134
Respiratory Protection
OSHA citation code: 19100134 I05 IV
Other22$0$0Aug 4, 2001--
02002A1910.1000
Air Contaminants
OSHA citation code: 19101000 A01
Other31$120$120Nov 25, 2001--
02002B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Other31$0$0Nov 25, 2001--
Dec 1, 1999Complaint (B) · Partial scope, Health#302553813$3,26214 viol.

Inspection #302553813

Dates

Opened
Dec 1, 1999
Closing Conference Date
Mar 15, 2000
Contested
May 18, 2000
Closed
Nov 14, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
52
Related Activity
1 complaint

Violations and Penalties

Total Violations
14
Violation Types
10 serious, 4 other-than-serious
Initial Penalties
$3,825
Penalties on Record
$3,262
Site Address
301 Nott Street, Bldg. 304, Schenectady, NY 12305
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Enforcement Outcome

Citation contest activity appears on May 18, 2000. Final orders are recorded through Jul 31, 2000. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Chemical Exposure Sampling21 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butanone100 - 34.7494ppm
2-Butoxyethanol110ppm
Antimony and Compounds (as Sb)30 - 0.022mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Chromium, Metal and Insoluble Salts30.0117 - 0.0288mg/m³
Cobalt, Metal, Dust and Fume (as Co)30 - 0.001mg/m³
Copper Fume (as Cu)30.024 - 0.0397mg/m³
Gravimetric DeterminationQC26.8666 - 7.2051mg/m³
Hexamethylene Diisocyanate70 - 0.0167mg/m³
Hexamethylene Diisocyanate Biuret70 - 0.3304mg/m³
Iron Oxide Fume39.3516 - 23.1384mg/m³
Lead, Inorganic (as Pb)30.0118 - 0.0314mg/m³
Manganese Fume (as Mn)30.1921 - 0.4676mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
n-Butyl Acetate140.8223 - 3.4229ppm
Nickel, Metal and Insoluble compounds (as Ni)30.0073 - 0.0114mg/m³
Sample WeightQC21.985 - 2.496mg
Silica, Crystalline Quartz (Respirable Fraction)27.6 - 10%
Stoddard Solvent70 - 208.7473mg/m³
Toluene250 - 56.7427ppm
Vanadium fume (as V2O5)30.0204 - 0.0748mg/m³
Xylene320 - 13.0826ppm
Zinc Oxide Fume319.5927 - 33.0698mg/m³

Violations

Violation list (5 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01002A1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious23$900$900May 21, 2000May 18, 2000Jul 31, 2000
01002B1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious43$0$0May 21, 2000May 18, 2000Jul 31, 2000
01002C1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVD
Serious65$0$0May 21, 2000--
010031910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious11$900$450Jun 5, 2000May 18, 2000Jul 31, 2000
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious11$1,125$562Jun 5, 2000May 18, 2000Jul 31, 2000

Showing the 5 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 21, 1998Planned (H) · Complete scope, Safety#302006705$1,0506 viol.

Inspection #302006705

Dates

Opened
Sep 21, 1998
Closing Conference Date
Sep 21, 1998
Closed
Nov 27, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 3 other-than-serious
Initial Penalties
$1,750
Penalties on Record
$1,050
Site Address
301 Nott Street, Bldg. 304, Schenectady, NY 12305
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious22$500$300Nov 4, 1998--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious33$625$375Nov 4, 1998--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious13$625$375Nov 4, 1998--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Other146$0$0Nov 4, 1998--
020021910.254
Arc Welding and Cutting
OSHA citation code: 19100254 B04 IV
Other12$0$0Nov 4, 1998--

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 10 of 11, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.106Flammable Liquids9 citations · $1,726
1910.134Respiratory Protection7 citations · $1,420
1910.1000Air Contaminants4 citations · $120

Chemical exposure sampling

Samples
213
Substances
27
Inspections
3

Sample results are listed in the record of each inspection that collected them.

Industry comparison

BLS 2024 survey: fabricated structural metal manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in SCHENECTADY, NY